Purpose: To prospectively assess the efficacy of self-expanding nitinol aortic stents in the treatment of coarctation of the aorta (CoA). Methods: Between July 2005 and July 2008, 21 patients (14 men; mean age 19.2 +/- 5.5 years, range 11-34) with CoA were treated with self-expanding Sinus-Aorta stents. The predilation balloon was selected to be <5 times the stenosis diameter. The stent diameter was selected to be 20% to 30% greater than the diameter of the undiseased aorta at the level of the diaphragm. Results:All procedures were successfully performed without any major complications. Predilation (mean balloon diameter 12.3 mm) and postdilation (mean balloon diameter 15.4 mm) were performed in 12 and 14 procedures, respectively. The mean diameter of the stents was 21.6 +/- 2.3 mm (range 18-26). The mean peak transcoarctation pressure gradient decreased from 57.4 +/- 19.5 mmHg (range 30-100) before the procedure to 1.2 +/- 2.2 mmHg (range 0-7; p<0.001). Cephalad stent dislodgement with the first-generation device occurred in 3 of 12 patients; 2 were treated with a second stent overlapping the first, and the third received 3 overlapped stents after the second stent migrated distally. No stent dislodgement occurred in the subsequent 9 patients treated with longer second-generation stents with anti-jump markers. None of the patients had dissection, arterial rupture, or other complications. On follow-up, 1 (5%) patient had recoarctation and minor stent migration after 18 months; another stent was deployed successfully. No evidence of aneurysm formation was seen in 7 patients undergoing arch imaging. Conclusion: CoA can be successfully and safely managed with self-expanding nitinol aortic stents without aortic wall complications. Stent malpositioning can be overcome using oversized stents with anti-jump markers. J Endovasc Ther. 2009;16:224-232
引用
收藏
页码:224 / 232
页数:9
相关论文
共 50 条
  • [31] IMPACT OF FINAL STENT DIMENSIONS ON ANGIOGRAPHIC RESTENOSIS FOLLOWING SELF-EXPANDING NITINOL STENT IMPLANTATION IN THE SUPERFICIAL FEMORAL ARTERY LESION
    Miki, Kojiro
    Fujii, Kenichi
    Kimura, Takumi
    Okada, Kozo
    Masuyama, Tohru
    Ishihara, Masaharu
    Fitzgerald, Peter
    Honda, Yasuhiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 313 - 313
  • [32] Midterm Outcomes of SMART Self-Expanding Nitinol Stent Implantation for Chronic Total Occlusion of Superficial Femoral Artery
    Sakamoto, Yasunari
    Muramatsu, Toshiya
    Hirano, Keisuke
    Soga, Yoshimitsu
    Yokoi, Hiroyoshi
    Nobuyoshi, Masakiyo
    Suzuki, Kenji
    Inoue, Naoto
    Ida, Osamu
    Nanto, Shinsuke
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B162 - B162
  • [33] Implantation of nitinol self-expanding carotid stent to release circumflex artery compression caused by mitral valve prosthesis
    Jaguszewski, Milosz
    Ciecwierz, Dariusz
    Fijalkowski, Marcin
    Rynkiewicz, Andrzej
    EUROPEAN HEART JOURNAL, 2011, 32 (10) : 1298 - 1298
  • [34] Sizing for self-expanding transcatheter aortic valve implantation
    Jilaihawi, Hasan
    Zhao, Zhen-Gang
    Williams, Mathew
    EUROINTERVENTION, 2018, 14 (05) : 490 - 493
  • [35] In vitro testing of a nitinol self-expanding stent made to fit the carotid bifurcation
    Martin, J
    Frid, N
    Gailloud, P
    Fumex, I
    Amor, M
    Ruefenacht, DA
    RADIOLOGY, 1998, 209P : 473 - 473
  • [36] The acute effect of stenting with the nitinol self-expanding coil stent: preliminary experience
    Ariel Roguin
    Rafael Beyar
    The International Journal of Cardiac Imaging, 1997, 13 : 441 - 450
  • [37] Nanomanufactured nitinol self-expanding stent graft in a carotid system in a porcine model
    Bailey, SR
    Sprague, E
    Boyle, C
    Velez, L
    Polan, J
    Palmaz, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 39A - 39A
  • [38] Stent implantation for aortic coarctation: The treatment of choice in adults?
    Rosenthal, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) : 1524 - 1527
  • [39] Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: The Cordis Enterprise stent
    Higashida, RT
    Halbach, VV
    Dowd, CF
    Juravsky, L
    Meagher, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (07) : 1751 - 1756
  • [40] The acute effect of stenting with the nitinol self-expanding coil stent: preliminary experience
    Roguin, A
    Beyar, R
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 441 - 450