Development of a model to predict air contaminant concentrations following indoor spills of volatile liquids

被引:15
|
作者
Reinke, PH
Brosseau, LM
机构
[1] University of Minnesota, Div. of Environ. and Occup. Health, Box 807 UMHC, 420 Delaware St. SE, Minneapolis
来源
ANNALS OF OCCUPATIONAL HYGIENE | 1997年 / 41卷 / 04期
关键词
D O I
10.1016/S0003-4878(96)00048-8
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A personal computer spreadsheet model which predicts air contaminant concentrations following indoor spills of volatile liquids has been developed. Three mass transfer models are compared for predicting evaporative flux in the model, the flat plate mass transfer theory, Penetration Theory, and Mackay and Matsugu models. Two methods of predicting spill temperature during evaporation are presented, the isothermal method, which assumes spill temperature remains at ambient throughout evaporation, and the spill temperature method, which predicts spill temperature using equations developed from a heat balance over the spill pool. Dispersion is approximated in the model as a well-mixed room with short-circuiting. Model equations are programmed into a Lotus 1,2,3 spreadsheet. Calculations of room concentration, spill pool surface temperature, and spill area are made at consecutive 20-s intervals following the spill. Model predictions are compared with concentration measurements made after two test spills in a laboratory. The model gives a good first estimate of room concentration, performing best when the spill is assumed to be isothermal and the Penetration Theory or Mackay and Matsugu methods are used to predict evaporation rate. (C) 1997 British Occupational Hygiene Society. Published by Elsevier Science Ltd.
引用
收藏
页码:415 / 435
页数:21
相关论文
共 50 条
  • [31] Evaluating differences between measured personal exposures to volatile organic compounds and concentrations in outdoor and indoor air
    Sexton, K
    Adgate, JL
    Mongin, SJ
    Pratt, GC
    Ramachandran, G
    Stock, TH
    Morandi, MT
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (09) : 2593 - 2602
  • [32] Observation of Conditions Preceding Peak Indoor Air Volatile Org Compound Concentrations in Vapor Intrusion Studies
    Lutes, Chris
    Holton, Chase
    Schumacher, Brian
    Zimmerman, John
    Kondash, Andrew
    Truesdale, Robert
    GROUND WATER MONITORING AND REMEDIATION, 2021, 41 (02): : 99 - 111
  • [33] Estimating evaporation rates and contaminant air concentrations due to small spills of non-ideal aqueous organic solvent mixtures in a controlled environment
    Abattan, Spero Franck
    Ryan, Patrick Eddy
    Lavoue, Jerome
    Halle, Stephane
    Bahloul, Ali
    Drolet, Daniel
    Debia, Maximilien
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2023, 20 (02) : 95 - 108
  • [34] Comparison of indoor and outdoor concentrations of CO at a public school. Evaluation of an indoor air quality model
    Chaloulakou, A
    Mavroidis, I
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (11) : 1769 - 1781
  • [35] Development of a line source indoor air quality model (LSIAQM)
    Naher, KS
    Cheong, KWD
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2828 - 2832
  • [36] Airborne Concentrations of Volatile Organic Compounds, Formaldehyde and Ammonia in Finnish Office Buildings with Suspected Indoor Air Problems
    Salonen, Heidi J.
    Pasanen, Anna-Liisa
    Lappalainen, Sanna K.
    Riuttala, Henri M.
    Tuomi, Tapani M.
    Pasanen, Pertti O.
    Back, Beatrice C.
    Reijula, Kari E.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2009, 6 (03) : 200 - 209
  • [37] Background concentrations of individual and total volatile organic compounds in residential indoor air of Schleswig-Holstein, Germany
    Hippelein, M
    JOURNAL OF ENVIRONMENTAL MONITORING, 2004, 6 (09): : 745 - 752
  • [38] CYCLING OF INDOOR AIR CONCENTRATIONS OF D-TRANS-ALLETHRIN FOLLOWING REPEATED PESTICIDE APPLICATIONS
    EITZER, BD
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1991, 47 (03) : 406 - 412
  • [39] SIMULATED AIR LEVELS OF VOLATILE ORGANIC-COMPOUNDS FOLLOWING DIFFERENT METHODS OF INDOOR INSECTICIDE APPLICATION
    BUKOWSKI, JA
    MEYER, LW
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) : 673 - 676
  • [40] Investigation of volatile organic compounds in the indoor air of a school over a one year period following refurbishment
    Crump, D
    Squire, R
    Brown, V
    Yu, C
    Coward, S
    Aizlewood, C
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 659 - 663