Integration of optical imaging with a small animal irradiator

被引:24
|
作者
Weersink, Robert A. [1 ,2 ]
Ansell, Steve [1 ]
Wang, An [1 ]
Wilson, Graham [1 ]
Shah, Duoaud [2 ]
Lindsay, Patricia E. [1 ,3 ]
Jaffray, David A. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Hlth Network, Techna Inst, Toronto, ON M5G 1P5, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 1A1, Canada
[4] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
关键词
small animal irradiation; optical imaging; CT imaging; targeting; BIOLUMINESCENCE TOMOGRAPHY; SYSTEM; FLUORESCENCE; RADIATION; RECONSTRUCTION; RADIOTHERAPY; CALIBRATION; ALGORITHMS; ACCURACY; SURFACE;
D O I
10.1118/1.4894730
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two-dimensional targeting of a light source in the mouse phantom based on optical imaging along the anterior/posterior direction was accurate to 0.55 mm. The mean square residual error in the normalized measured projected surface intensities versus the calculated normalized intensities ranged between 0.0016 and 0.006. Optimizing the position reduced this error from 0.00016 to 0.0004 with distances ranging between 0.7 and 1 mm between the actual and calculated position source positions. Conclusions: The integration of optical imaging on an existing small animal irradiation platform has been accomplished. A targeting accuracy of 1 mm can be achieved in rigid, homogeneous phantoms. The combination of optical imaging with a CBCT image-guided small animal irradiator offers the potential to deliver functionally targeted dose distributions, as well as monitor spatial and temporal functional changes that occur with radiation therapy. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Design of the Washington University Small Animal Conformal Micro Irradiator
    Izaguirre, E. W.
    Diao, X.
    Stojadinovic, S.
    Mutic, S.
    Khullar, D.
    Deasy, J.
    Parikh, P.
    Hope, A.
    Grigsby, P.
    Low, D. A.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] Optical small animal imaging in the drug discovery process
    Dufort, S.
    Sancey, L.
    Wenk, C.
    Josserand, V.
    Coll, J. L.
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2010, 1798 (12): : 2266 - 2273
  • [33] Small animal in vivo optical imaging in radiation biology
    Dubois, L
    Theys, J
    Chiu, R
    Mengesha, A
    Landuyt, W
    Koritznsky, M
    Wouters, BG
    Lambin, P
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S281 - S281
  • [34] Dosimetric characterization of an image-guided stereotactic small animal irradiator
    Pidikiti, R.
    Stojadinovic, S.
    Speiser, M.
    Song, K. H.
    Hager, F.
    Saha, D.
    Solberg, T. D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2585 - 2599
  • [35] Dosimetric verification and commissioning for a small animal image-guided irradiator
    Wang, Yi-Fang
    Lin, Shih-Chi
    Na, Yong Hum
    Black, Paul J.
    Wuu, Cheng-Shie
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [36] Immune-Mediated Effects of Microplanar Radiotherapy with a Small Animal Irradiator
    Bazyar, Soha
    O'Brien, Edward Timothy, III
    Benefield, Thad
    Roberts, Victoria R.
    Kumar, Rashmi J.
    Gupta, Gaorav P.
    Zhou, Otto
    Lee, Yueh Z.
    CANCERS, 2022, 14 (01)
  • [37] Dosimetric Verification and Commissioning for an Image-Guided Small Animal Irradiator
    Wang, Y. F.
    Lin, S. C.
    Na, Y. H.
    Black, P. J.
    Wuu, C. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E624 - E624
  • [38] Monte Carlo Feasibility Study of a Compact Microbeam Small Animal Irradiator
    Schreiber, E.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [39] SMALL IRRADIATOR
    不详
    ISOTOPES AND RADIATION TECHNOLOGY, 1971, 9 (01): : 112 - &
  • [40] Integration of AdaptiSPECT, a small-animal adaptive SPECT imaging system
    Chaix, Cecile
    Kovalsky, Stephen
    Kosmider, Matthew
    Barrett, Harrison H.
    Furenlid, Lars R.
    MEDICAL APPLICATIONS OF RADIATION DETECTORS III, 2013, 8853