Integration of optical imaging with a small animal irradiator

被引:24
|
作者
Weersink, Robert A. [1 ,2 ]
Ansell, Steve [1 ]
Wang, An [1 ]
Wilson, Graham [1 ]
Shah, Duoaud [2 ]
Lindsay, Patricia E. [1 ,3 ]
Jaffray, David A. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Hlth Network, Techna Inst, Toronto, ON M5G 1P5, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 1A1, Canada
[4] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
关键词
small animal irradiation; optical imaging; CT imaging; targeting; BIOLUMINESCENCE TOMOGRAPHY; SYSTEM; FLUORESCENCE; RADIATION; RECONSTRUCTION; RADIOTHERAPY; CALIBRATION; ALGORITHMS; ACCURACY; SURFACE;
D O I
10.1118/1.4894730
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two-dimensional targeting of a light source in the mouse phantom based on optical imaging along the anterior/posterior direction was accurate to 0.55 mm. The mean square residual error in the normalized measured projected surface intensities versus the calculated normalized intensities ranged between 0.0016 and 0.006. Optimizing the position reduced this error from 0.00016 to 0.0004 with distances ranging between 0.7 and 1 mm between the actual and calculated position source positions. Conclusions: The integration of optical imaging on an existing small animal irradiation platform has been accomplished. A targeting accuracy of 1 mm can be achieved in rigid, homogeneous phantoms. The combination of optical imaging with a CBCT image-guided small animal irradiator offers the potential to deliver functionally targeted dose distributions, as well as monitor spatial and temporal functional changes that occur with radiation therapy. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Small Animal Stereotactic Irradiator
    Pidikiti, R.
    Stojadinovic, S.
    Song, K.
    Seliounine, S.
    Speiser, M.
    Saha, D.
    Solberg, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] SMALL ANIMAL SBRT IRRADIATOR
    Pidikiti, R.
    Stojadinovic, S.
    Song, K.
    Speiser, M.
    Seliounine, S.
    Saha, D.
    Solberg, T.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S117 - S117
  • [3] Small animal irradiator dose distribution verification using radioluminescence imaging
    Spinelli, Antonello E.
    D'Agostino, Emilano
    Broggi, Sara
    Claudio, Fiorino
    Boschi, Federico
    JOURNAL OF BIOPHOTONICS, 2020, 13 (07)
  • [4] Real time small animal irradiator dosimetry using Radioluminescence imaging
    Spinelli, A.
    D'Agostino, E.
    Broggi, S.
    Fiorino, C.
    Boschi, F.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S913 - S914
  • [5] MicroRT - Small animal conformal irradiator
    Stojadinovic, S.
    Low, D. A.
    Hope, A. J.
    Vicic, M.
    Deasy, J. O.
    Cui, J.
    Khullar, D.
    Parikh, P. J.
    Malinowski, K. T.
    Izaguirre, E. W.
    Mutic, S.
    Grigsby, P. W.
    MEDICAL PHYSICS, 2007, 34 (12) : 4706 - 4716
  • [6] microRT: A conformal small animal irradiator
    Low, DA
    Vicic, M
    Mutic, S
    Grigsby, PW
    Deasy, JO
    Hope, A
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1365 - 1368
  • [7] Radiochromic Film Characterization of a Small Animal Irradiator
    Lynch, B.
    Samant, S.
    Helmig, R.
    Zhang, A.
    Zhang, L.
    Liu, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Advanced irradiator for the small animal conformal treatment
    Vicic, M
    Stojadinovic, S
    Low, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2010 - 2010
  • [9] Dosimetric properties of a MicroRT small animal irradiator
    Mutic, S
    Vicic, M
    Low, D
    Deasy, J
    Hope, A
    Robertson, D
    Grigsby, P
    MEDICAL PHYSICS, 2004, 31 (06) : 1881 - 1881
  • [10] Dosimetric Characterization of Stereotactic Small Animal Irradiator
    Pidikiti, R.
    Stojadinovic, S.
    Song, K.
    Speiser, M.
    Seliounine, S.
    Saha, D.
    Solberg, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S671 - S671