Highly Selective Ratiometric Fluorescent Sensor for La(III) Ion Based on a New Schiff's Base

被引:26
|
作者
Hosseini, Morteza [1 ]
Ganjali, Mohammad Reza [2 ]
Veismohammadi, Bahareh [2 ]
Riahl, Siavash [2 ,3 ]
Norouzi, Parviz [2 ]
Salavati-Niasari, Masoud [4 ]
Abkenar, Shiva Dehghan [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Savadkooh Branch, Savadkooh, Iran
[2] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[3] Univ Tehran, Fac Engn, Inst Petr Engn, Tehran, Iran
[4] Univ Kashan, Fac Sci, Dept Chem, Kashan, Iran
关键词
Fluorescence; lantanium; ratiometric; Schiff's base; sensor; RARE-EARTH-ELEMENTS; SPECTROPHOTOMETRIC DETERMINATION; MEMBRANE; CHEMOSENSOR; EMISSION; SEPARATION; LANTHANUM; SYSTEM;
D O I
10.1080/00032710902807839
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fluorescent sensor containing (1-[({2-[2-(2-hydroxy-1-naphtyl)-3-(2-{[(E)-1-(2-hydroxy-1-naphtyl)methylidene]amino}ethyl)-1-imidazolidinyl]ethyl}imino)methyl]-2-naphthol) (L) was synthesized for detecting La(III) ratiometrically. Complexation between compound L and La(III) with high selectivity gives rise to a great red shift from 430 to 522nm in the emission spectra. In acetonitrile, the red shift of fluorescent emission upon lanthanium binding is due to the formation of a 1:1 metal-ligand complex. The fluorescent probe exhibits high selectivity over other common metal ions and mono-, di-, and trivalent cations, which indicates good selectivity for La(III) ions over a large number of interfering cations.
引用
收藏
页码:1029 / 1040
页数:12
相关论文
共 50 条
  • [31] Highly selective and sensitive turn-on fluorescent sensor for detection of Al3+ based on quinoline-base Schiff base
    Wang, Yang
    Ma, Zhong-Ying
    Zhang, De-Long
    Deng, Jia-Li
    Chen, Xiong
    Xie, Cheng-Zhi
    Qiao, Xin
    Li, Qing-Zhong
    Xu, Jing-Yuan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 195 : 157 - 164
  • [32] A highly selective salicylate electrode based on Schiff base complexes of cobalt(III)
    Chai, YQ
    Jiang, F
    Yuan, R
    Xu, L
    Xu, WJ
    ANALYTICAL LETTERS, 2003, 36 (11) : 2379 - 2392
  • [33] Highly selective and sensitive chemosensor for Al(III) based on isoquinoline Schiff base
    Huang, Yu-Ying
    Wang, Feng-Xue
    Mu, Si-Yu
    Sun, Xian
    Li, Qing-Zhong
    Xie, Cheng-Zhi
    Liu, Hai-Bo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 243
  • [34] A New Schiff Base Based Fluorescent Sensor for Al(III) Based on 2-Hydroxyacetophenone and o-Phenylenediamine
    Bharali, Bidisha
    Talukdar, Hrishikesh
    Phukan, Prodeep
    Das, Diganta Kumar
    JOURNAL OF FLUORESCENCE, 2020, 30 (04) : 751 - 757
  • [35] A New Schiff Base Based Fluorescent Sensor for Al(III) Based on 2-Hydroxyacetophenone and o-Phenylenediamine
    Bidisha Bharali
    Hrishikesh Talukdar
    Prodeep Phukan
    Diganta Kumar Das
    Journal of Fluorescence, 2020, 30 : 751 - 757
  • [36] Novel lanthanum(III) membrane sensor based on a new N-S Schiff's base
    Ganjali, MR
    Qomi, M
    Daftari, A
    Norouzi, P
    Salavati-Niasari, M
    Rabbani, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (01) : 92 - 96
  • [37] Novel Dy(III) sensor based on a new bis-pyrrolidene Schiff's base
    Ganjali, MR
    Ravanshad, J
    Hosseini, M
    Salavati-Niasari, M
    Pourjavid, MR
    Baezzat, MR
    ELECTROANALYSIS, 2004, 16 (21) : 1771 - 1776
  • [38] Novel terbium(III) sensor based on a new bis-pyrrolidene Schiff's base
    Ganjali, MR
    Ghesmi, A
    Hosseini, M
    Pourjavid, MR
    Rezapour, M
    Shamsipur, M
    Salavati-Niasari, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02) : 334 - 339
  • [39] Highly Sensitive and Selective Fluorescent Sensor for Zinc Ion Based on a New Diarylethene with a Thiocarbamide Unit
    Zhang, Congcong
    Pu, Shouzhi
    Sun, Zhiyuan
    Fan, Congbin
    Liu, Gang
    JOURNAL OF PHYSICAL CHEMISTRY B, 2015, 119 (13): : 4673 - 4682
  • [40] Ruthenium(III) Schiff's base complex as novel chloride selective membrane sensor
    Ganjali, MR
    Pourjavid, MR
    Rezapour, M
    Poursaberi, T
    Daftari, A
    Salavati-Niasari, M
    ELECTROANALYSIS, 2004, 16 (11) : 922 - 927