Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs

被引:25
|
作者
Timmermans, C
Rodriguez, LM
Van Suylen, RJ
Leunissen, J
Vos, M
Ayers, GM
Crijns, HJGM
Wellens, HJJ
机构
[1] Acad Hosp Maastricht, Cardiovasc Res Inst Maastricht, Dept Cardiol, Maastricht, Netherlands
[2] Acad Hosp Maastricht, Dept Pathol, Maastricht, Netherlands
[3] CryoCor Inc, San Diego, CA USA
关键词
catheter-based cryoablation; radiofrequency ablation; cavotricuspid isthmus;
D O I
10.1023/A:1020885721262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Catheter-based cryoablation has been shown to produce punctate and effective cardiac lesions to treat focal targets. However, sequential applications are required to produce a continuous linear lesion needed to cure macroreentrant arrhythmias with large critical isthmuses. The purpose of this study was to compare and contrast linear cardiac lesions produced with sequential applications using a novel cryoablation system to those produced using radiofrequency (RF) energy. Methods and Results: Seven mongrel dogs were prepared for femoral venous insertion of the ablation catheter (either a 10-French, 6-mm tipped, bipolar cryoablation catheter (N = 5 cryo group) or a 7-French, 4-mm tipped, bipolar RF ablation catheter (N = 2, RF group)). Ablation of the cavotricuspid isthmus was performed by delivering applications at sequential locations across the isthmus. The cryo group received 6 to 10 (mean 8 +/- 1.4), 5-minute applications at 3 to 5 separate sites with a mean nadir temperature of -74.5 +/- 1.6degreesC. Each dog in the RF group received 9, 90-second applications with a mean temperature and power of 62 +/- 0degreesC and 32 +/- 3.6 W. No acute or chronic complications were associated with either form of ablation. Immediately and six weeks after the index procedure, electroanatomical mapping showed the presence of bidirectional isthmus conduction block in all dogs. Gross and histopathologic examination revealed the presence of linear lesions, which were continuous and transmural. Conclusion: Similar to RF ablation, catheter-based cryoablation can produce linear, transmural lesions in the cavotricuspid isthmus resulting in permanent bidirectional isthmus conduction block.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [41] Percutaneous catheter-based cryoablation of the renal artery is effective for sympathetic denervation in a sheep model
    Prochnau, D.
    Figulla, H. R.
    Romeike, B. F. M.
    Franz, M.
    Schubert, H.
    Bischoff, S.
    Lauten, A.
    Kuehnert, H.
    Surber, R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 152 (02) : 268 - 270
  • [42] Catheter-Based Cryoablation of Postinfarction and Idiopathic Ventricular Tachycardia: Initial Experience in a Selected Population
    Timmermans, Carl
    Manusama, Randy
    Alzand, Becker
    Rodriguez, Luz-Maria
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (03) : 255 - 261
  • [43] Trans-isthmus conduction block in patients with atrial flutter assessed with a noncontact mapping catheter
    Goyal, R
    Pelosi, F
    Flemming, M
    Souza, J
    Zivin, A
    Knight, BP
    Man, KC
    Strickberger, SA
    Morady, F
    CIRCULATION, 1998, 98 (17) : 282 - 282
  • [44] Epicardial-side Conduction During Cavotricuspid Isthmus Ablation; Prevalence, Significance, and a Novel Sign 'Sigmoid Pattern' of Halo Catheter on the Tricuspid Annulus
    Nakajima, Tamio
    Nishida, Taku
    Sugimoto, Hiroyuki
    Oomori, Sawako
    Okayama, Satoshi
    Watanabe, Makoto
    Naito, Masaki
    Uemura, Shiro
    Saito, Yoshihiko
    CIRCULATION, 2009, 120 (18) : S644 - S644
  • [45] Mitral isthmus conduction block: intriguing result of radiofrequency catheter ablation for a left concealed accessory pathway
    Bulava, Alan
    Hanis, Jiri
    Sitek, David
    EUROPACE, 2010, 12 (04): : 579 - 581
  • [46] Apparent Bidirectional Conduction Block Following Radiofrequency Catheter Ablation of Typical Atrial Flutter
    Robert F. Quintos
    Tawfik Barakat
    Andrew Mecca
    Brian Olshansky
    Journal of Interventional Cardiac Electrophysiology, 2001, 5 : 109 - 118
  • [47] Apparent bidirectional conduction block following radiofrequency catheter ablation of typical atrial flutter
    Quintos, RF
    Barakat, T
    Mecca, A
    Olshansky, B
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (01) : 109 - 118
  • [48] Catheter ablation of typical atrial flutter -: A randomized comparison of 2 methods for determining complete bidirectional isthmus block
    Anselme, F
    Savouré, A
    Cribier, A
    Saoudi, N
    CIRCULATION, 2001, 103 (10) : 1434 - 1439
  • [49] Novel catheter-based transgene delivery to the myocardium is well tolerated in healthy dogs
    Sleeper, M. M.
    Bish, L.
    Reynolds, C.
    Withnall, E.
    Russell, N.
    Arndt, J.
    Peddle, G.
    Buchlis, G.
    Davison, E.
    Gao, G.
    Wilson, J.
    Sweeney, H. L.
    HUMAN GENE THERAPY, 2008, 19 (04) : 402 - 402
  • [50] Mitral isthmus ablation with a circular mapping catheter positioned in the left atrial appendage as a reference for complete conduction block
    Nishiyama, T.
    Kashimura, S.
    Katsumata, Y.
    Kimura, T.
    Nishiyama, N.
    Tanimoto, Y.
    Aizawa, Y.
    Fukuda, K.
    Takatsuki, S.
    EUROPEAN HEART JOURNAL, 2015, 36 : 573 - 574