Effect of verapamil on home self-measurement of blood pressure and heart rate in hypertensive patients

被引:5
|
作者
Fernández-González, R
Gómez-Pajuelo, C
Gabriel, R
de la Figuera, M
Moreno, E
机构
[1] Labs Knoll SA, Dept Med, Madrid 28050, Spain
[2] Hosp 12 Octubre, Dept Cardiol, E-28041 Madrid, Spain
[3] Hosp Univ Princesa, Clin Epidemiol Unit, Madrid, Spain
[4] PCC La Mina, Teaching Unit Family & Community Med, Barcelona, Spain
关键词
hypertension; self-measurement of blood pressure; heart rate; verapamil;
D O I
10.1097/00126097-200002000-00005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Achievement of a controlled blood pressure and improvement of cardiovascular risk profile are the mainstays of therapy for hypertension, Objective To assess the responses of heart rate and blood pressure in hypertensive patients to 240 mg/day sustained release verapamil, Methods We assessed the effect of 240 mg/day sustained released verapamil on blood pressure and heart rate, measured in the office and at home, in 1395 hypertensive outpatients with mild-to-moderate hypertension, who were using an Omron HEM 705 CP automatic device for self-measurement, The period of observation was 3 months. Results Blood pressure decreased both in the medical office and at the patient's home, the measurements obtained at home being lower than those found in the office. Heart rate decreased in a significant and particular way. The decrease was greatest among those patients with histories of myocardial infarction and among relatively young patients, who exhibit a tendency towards higher than normal baseline heart rates. Overall, there was a shift of the heart-rate curve towards more controlled levels clustered around heart rates between 65 and 75 beats/min. Home self-measurement showed that the data gathered by the patients at home are reliable and that, when cut-off values of 140/90 mmHg for blood pressure are used, the percentage of patients with controlled blood pressures is 62%, whereas the percentage obtained in the medical office by the physician is 56%. If cut-off values of 135/85 mmHg are considered for self-measurements at home, according to the VI JNC recommendations, the percentage of patients with controlled blood pressures is 25.4%, (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [41] Effect of anticipation and cuff inflation on blood pressure during self-measurement
    Gazzola, Katia
    Honingh, Marloes
    Truijen, Jasper
    Zuliani, Giovanni
    Van den Born, Bert-Jan H.
    JOURNAL OF HYPERTENSION, 2018, 36 (09) : 1798 - 1802
  • [42] Reproducibility and cost of blood pressure self-measurement using the 'Loaned Self-measurement Equipment Model'
    Calvo-Vargas, C
    Rios, VP
    Troyo-Sanromán, R
    Grover-Paez, F
    BLOOD PRESSURE MONITORING, 2001, 6 (05) : 225 - 232
  • [43] SELF-MEASUREMENT OF BLOOD-PRESSURE - ISSUES RELATED TO THE TRAINING OF PATIENTS
    BIRKETT, NJ
    ABBOTT, D
    CAMPBELL, NRC
    CHOCKALINGAM, A
    DAGENAIS, GR
    HOGAN, K
    CANADIAN JOURNAL OF CARDIOLOGY, 1995, 11 : H23 - H28
  • [44] What is the value of home (self) blood pressure monitoring in patients with hypertensive heart disease?
    Mengden, T
    Schwartzkopff, B
    Strauer, BE
    AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (07) : 813 - 819
  • [45] E-PERTENSION STUDY: PROOF OF CONCEPT OF AN ENABLEMENT SUITE FOR THE SELF-MEASUREMENT OF BLOOD PRESSURE IN HYPERTENSIVE PATIENTS
    Tomas, M.
    Noel, C.
    Delmotte, P.
    JOURNAL OF HYPERTENSION, 2019, 37 : E257 - E257
  • [46] Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice?
    Myers, Martin G.
    Valdivieso, Miguel
    Chessman, Mary
    Kiss, Alexander
    BLOOD PRESSURE MONITORING, 2010, 15 (06) : 300 - 304
  • [47] Effect of self-measurement of blood pressure on adherence to treatment in patients with mild-to-moderate hypertension
    van Onzenoort, Hein A. W.
    Verberk, Willem J.
    Kroon, Abraham A.
    Kessels, Alfons G. H.
    Nelemans, Patricia J.
    van der Kuy, Paul-Hugo M.
    Neef, Cees
    de Leeuw, Peter W.
    JOURNAL OF HYPERTENSION, 2010, 28 (03) : 622 - 627
  • [48] DETECTION OF NOCTURNAL HYPERTENSION BY SELF-MEASUREMENT OF BLOOD PRESSURE MEASUREMENT
    Ozono, Ryoji
    JOURNAL OF HYPERTENSION, 2023, 41 : E207 - E207
  • [49] EFFECTS OF VERAPAMIL ON BLOOD-PRESSURE AND HEART-RATE IN NEUROGENIC HYPERTENSIVE RATS
    VASQUEZ, EC
    MILL, JG
    CABRAL, AM
    EUROPEAN JOURNAL OF PHARMACOLOGY, 1984, 105 (3-4) : 215 - 221
  • [50] Effect of self-initiated and fully-automated self-measurement on blood pressure
    Rosanne T. Berkhof
    Katia Gazzola
    Bert-Jan H. van den Born
    Journal of Human Hypertension, 2020, 34 : 176 - 183