Role of transcranial Doppler and stump pressure during carotid endarterectomy

被引:25
|
作者
Finocchi, C
Gandolfo, C
Carissimi, T
DelSette, M
Bertoglio, C
机构
[1] Dept. Neurosci. and Neurol. Rehab., University of Genova, 16131 Genova
关键词
carotid endarterectomy; cerebral ischemia; transcranial Doppler;
D O I
10.1161/01.STR.28.12.2448
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The aim of our study was to clarify the pathophysiology of perioperative cerebral complications during carotid endarterectomy in our series. Methods By means of transcranial Doppler ultrasonography and slump pressure measurement, we monitored 112 patients who underwent carotid endarterectomy under general anesthesia for symptomatic or asymptomatic severe carotid stenosis. Results Of 18 patients who underwent carotid endarterectomy with intra-arterial shunt, 2 (11.1%) developed an ischemic stroke. Of the other 94 patients, one suffered a nucleocapsular hemorrhage and 5 had cerebral ischemic complications. In these 5 patients, the duration of clamping was significantly longer (mean +/- SD, 16.4 +/- 1.1 versus 12.7 +/- 2.6 minutes; P = .0019). and the decrease of middle cerebral artery mean velocity on clamping was significantly greater (mean +/- SD, 56.4 +/- 4.9% versus 28.8 +/- 20.2%; P = .0031), while stump pressure was not significantly different, Microembolic signals were recorded in 70 patients (62.5%) and were not associated with cerebral ischemic complications. The 7 patients who developed cerebral ischemic complications had a significantly higher percentage of stenosis in the contralateral internal carotid artery (mean +/- SD, 82.0 +/- 17.8% versus 29.3 +/- 36.4%; P = .0018). Conclusions The results of our study suggest that the major complications of carotid endarterectomy may be due to hemodynamic factors. Stump pressure alone is not a reliable indicator of hemodynamic changes that predict cerebral ischemia. Particulate microembolism may cause more subtle changes in cerebral parenchyma, but further studies are needed to clarify this point.
引用
收藏
页码:2448 / 2452
页数:5
相关论文
共 50 条
  • [41] Cerebral Microembolization During Carotid Endarterectomy versus Carotid Stenting Using Transcranial Doppler Monitoring
    Gupta, Naren
    Wang, Jeffrey Y.
    Robertson, Gregory C.
    Kasirajan, Karthikeshwar
    CIRCULATION, 2009, 120 (18) : S955 - S955
  • [42] Cerebral injury predicted by transcranial Doppler ultrasonography but not electroencephalography during carotid endarterectomy
    Costin, M
    Rampersad, A
    Solomon, RA
    Connolly, ES
    Heyer, EJ
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2002, 14 (04) : 287 - 292
  • [43] INTRACRANIAL ARTERIAL RESISTANCE DURING CAROTID ENDARTERECTOMY EVALUATED BY TRANSCRANIAL DOPPLER ULTRASOUND
    SCHWARZE, JJ
    BABIKIAN, VL
    CANTELMO, NL
    JOHNSON, WC
    ANNALS OF NEUROLOGY, 1993, 34 (02) : 289 - 289
  • [44] Microemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomy
    Jordan, WD
    Voellinger, DC
    Doblar, DD
    Plyushcheva, NP
    Fisher, WS
    McDowell, HA
    CARDIOVASCULAR SURGERY, 1999, 7 (01): : 33 - 38
  • [45] TRANSCRANIAL DOPPLER MONITORING OF CEREBRAL BLOOD-FLOW DURING CAROTID ENDARTERECTOMY
    TETICKOVIC, E
    MIKSIC, K
    ZDRAVSTVENI VESTNIK, 1992, 61 (5-6): : 249 - 254
  • [46] The benefit of the intraoperative transcranial Doppler and electroencephalography for carotid endarterectomy
    Fong, W. C.
    Wong, K.
    Cheng, K. M.
    Tse, C. W.
    Chan, H. M. J.
    Chong, W.
    Li, C. K. P.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 285 : S222 - S222
  • [47] Combined transcranial Doppler and electrophysiologic monitoring for carotid endarterectomy
    Fiori, L
    Parenti, G
    Marconi, F
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1997, 9 (01) : 11 - 16
  • [48] RELATIONSHIP OF INTRAOPERATIVE EEG MONITORING AND STUMP PRESSURE MEASUREMENTS DURING CAROTID ENDARTERECTOMY
    BREWSTER, DC
    OHARA, PJ
    DARLING, RC
    HALLETT, JW
    CIRCULATION, 1979, 60 (04) : 4 - 4
  • [50] Prevention of postoperative thrombotic stroke after carotid endarterectomy: The role of transcranial Doppler ultrasound
    Lennard, N
    Smith, J
    Dumville, J
    Abbott, R
    Evans, DH
    London, NJM
    Bell, PRF
    Naylor, AR
    JOURNAL OF VASCULAR SURGERY, 1997, 26 (04) : 579 - 584