An FDTD model for calculation of gradient-induced eddy currents in MRI system

被引:41
|
作者
Liu, F [1 ]
Crozier, S [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
基金
美国国家卫生研究院; 澳大利亚研究理事会;
关键词
cylindrical coordinate; eddy current; finite-difference time-domain (FDTD); low frequency; magnetic resonance imaging (MRI); superconducting magnet;
D O I
10.1109/TASC.2004.830609
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In most magnetic resonance imaging (MRI) systems, pulsed magnetic gradient fields induce eddy currents in the conducting structures of the superconducting magnet. The eddy currents induced in structures within the cryostat are particularly problematic as they are characterized by long time constants by virtue of the low resistivity of the conductors. This paper presents a three-dimensional (3-D) finite-difference time-domain (FDTD) scheme in cylindrical coordinates for eddy-current calculation in conductors. This model is intended to be part of a complete FDTD model of an MRI system including all RF and low-frequency field generating units and electrical models of the patient. The singularity apparent in the governing equations is removed by using a series expansion method and the conductor-air boundary condition is handled using a variant of the surface impedance concept. The numerical difficulty due to the "asymmetry" of Maxwell equations for low-frequency eddy-current problems is circumvented by taking advantage of the known penetration behavior of the eddy-current fields. A perfectly matched layer absorbing boundary condition in 3-D cylindrical coordinates is also incorporated. The numerical method has been verified against analytical solutions for simple cases. Finally, the algorithm is illustrated by modeling a pulsed field gradient coil system within an MRI magnet system. The results demonstrate that the proposed FDTD scheme can be used to calculate large-scale eddy-current problems in materials with high conductivity at low frequencies.
引用
收藏
页码:1983 / 1989
页数:7
相关论文
共 50 条
  • [21] Simulated Design Strategies for SPECT Collimators to Reduce the Eddy Currents Induced by MRI Gradient Fields
    Samoudi, Amine M.
    Van Audenhaege, Karen
    Vermeeren, Gunter
    Verhoyen, Gregory
    Martens, Luc
    Van Holen, Roel
    Joseph, Wout
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 2017 - 2022
  • [22] A theoretical framework of gradient coil designed to mitigate eddy currents for a permanent magnet MRI system
    Zhang, Peng
    Wang, Wendong
    Shi, Yikai
    TECHNOLOGY AND HEALTH CARE, 2022, 30 : S315 - S328
  • [23] Finite element analysis of gradient z-coil induced eddy currents in a permanent MRI magnet
    Li, Xia
    Xia, Ling
    Chen, Wufan
    Liu, Feng
    Crozier, Stuart
    Xie, Dexin
    JOURNAL OF MAGNETIC RESONANCE, 2011, 208 (01) : 148 - 155
  • [24] A contribution to MRI safety testing related to gradient-induced heating of medical devices
    Arduino, Alessandro
    Bottauscio, Oriano
    Chiampi, Mario
    Zanovello, Umberto
    Zilberti, Luca
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 930 - 944
  • [25] Characterization and Correction of Diffusion Gradient-Induced Eddy Currents in Second-Order Motion-Compensated Echo-Planar and Spiral Cardiac DTI
    van Gorkum, Robbert J. H.
    Guenthner, Christian
    Koethe, Andreas
    Stoeck, Christian T.
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2378 - 2394
  • [26] Two-parametric prescan calibration of gradient-induced sampling errors for rosette MRI
    Latta, Peter
    Jirik, Radovan
    Vitous, Jiri
    Macicek, Ondrej
    Vojtisek, Lubomir
    Rektor, Ivan
    Standara, Michal
    Kristek, Jan
    Starcuk, Zenon, Jr.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1285 - 1297
  • [27] Simulation of Gradient-Coil-Induced Eddy Currents and Their Effects on a Head-Only HTS MRI Magnet
    Poole, Michael
    Lopez, Hector Sanchez
    Ozaki, Osamu
    Kitaguchi, Hitoshi
    Nakajima, Iwao
    Urayama, Shin-ichi
    Sato, Ken-ichi
    Fukuyama, Hidenao
    Crozier, Stuart
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (06) : 3592 - 3598
  • [28] Comparative study of symmetric and asymmetric cylindrical MRI gradient y-coils in terms of induced eddy currents
    Trakic, Adnan
    Liu, Feng
    Crozier, Stuart
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7016 - 7019
  • [29] Mitigation of Intra-coil Eddy Currents in Split Gradient Coils in a Hybrid MRI-LINAC System
    Tang, Fangfang
    Freschi, Fabio
    Repetto, Maurizio
    Li, Yu
    Liu, Feng
    Crozier, Stuart
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (03) : 725 - 732
  • [30] Efficient prediction of MRI gradient-induced heating for guiding safety testing of conductive implants
    Zanovello, Umberto
    Fuss, Carina
    Arduino, Alessandro
    Bottauscio, Oriano
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 2011 - 2018