Impurity profiling of methamphetamine hydrochloride drugs seized in the Philippines

被引:39
|
作者
Dayrit, FA
Dumlao, MC
机构
[1] Ateneo Manila Univ, Dept Chem, Quezon City, Philippines
[2] Philippine Natl Police Crime Lab, Quezon City, Philippines
关键词
methamphetamine hydrochloride; profiling of drug impurities; cluster analysis;
D O I
10.1016/j.forsciint.2004.03.002
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Methaniphetamine hydrochloride is one of the most widely used illicit drugs in the Philippines. In this study, we describe the application of cluster analysis of trace impurities in the profiling of the seized methamphetamine drug samples. Thirty milligrams of a homogenized drug sample were dissolved in I mL of pH 10.5 buffer solution and extracted with ethyl acetate containing three internal standards. The trace impurities were identified using gas chromatography-mass spectrometry (GC-MS) and quantified by gas chromatography with a flame ionization detector (GC-FID). Following previously reported methodologies, 30 impurity peaks were selected from the GC-FID chromatograms. The peak areas and retention times were referenced to the internal standards. The peak areas of the selected peaks were then grouped for cluster analysis. In order to check for consistency of clustering, two further cluster analyses were performed using 40 and 50 impurity peaks. Changes in clustering were observed in going from 30 to 40 impurity peaks, while analyses using 40 and 50 impurity peaks gave similar results. Thus, for the seized drug samples used in this study, cluster analysis using at least 40 impurity peaks showed better consistency of clustering as compared to analysis using 30 peaks only. Ten of the impurity peaks were identified, of which four were identified for the first time in methamphetamine drug samples. These are p-bromotoulene, N-benzyl amphetamine, N-ethyl amphetamine, and N-ethyl methamphetamine. The presence of phenyl-2-propanone (P2P), N,N-dimethyl amphetamine, and N-formyl amphetamine is indicative that these casework samples were synthesized using the Leuckart method. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [21] Forensic application of chiral separation of amphetamine-type stimulants to impurity analysis of seized methamphetamine by capillary electrophoresis
    Iwata, Yuko T.
    Inoue, Hiroyuki
    Kuwayama, Kenji
    Kanamori, Tatsuyuki
    Tsujikawa, Kenji
    Miyaguchi, Hajime
    Kishi, Tohru
    FORENSIC SCIENCE INTERNATIONAL, 2006, 161 (2-3) : 92 - 96
  • [22] Impurity profiling of ecstasy tablets seized in Hong Kong by gas chromatography-mass spectrometry
    Cheng, Jack Yuk Ki
    Chan, Man Fai
    Chan, Tai Wai
    Hung, Mei Yuen
    FORENSIC SCIENCE INTERNATIONAL, 2006, 162 (1-3) : 87 - 94
  • [23] Animal drugs seized
    不详
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1999, 214 (01) : 21 - 21
  • [24] Choice of capillary electrophoresis systems for the impurity profiling of drugs
    Hilhorst, MJ
    Somsen, GW
    de Jong, GJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (07) : 1251 - 1260
  • [25] ANALYSIS OF INORGANIC IMPURITIES IN SEIZED METHAMPHETAMINE SAMPLES
    MARUMO, Y
    INOUE, T
    SETA, S
    FORENSIC SCIENCE INTERNATIONAL, 1994, 69 (01) : 89 - 95
  • [26] Methamphetamine impurity profiling using a 0.32 mm id nonpolar capillary column
    Inoue, H
    Kanamori, T
    Iwata, YT
    Ohmae, Y
    Tsujikawa, K
    Saitoh, S
    Kishi, T
    FORENSIC SCIENCE INTERNATIONAL, 2003, 135 (01) : 42 - 47
  • [27] IMPURITY PROFILING OF METHYLAMPHETAMINE IN AUSTRALIA AND THE DEVELOPMENT OF A NATIONAL DRUGS DATABASE
    PERKAL, M
    NG, YL
    PEARSON, JR
    FORENSIC SCIENCE INTERNATIONAL, 1994, 69 (01) : 77 - 87
  • [28] Synthesis and organic impurity profiling of 4-methoxymethamphetamine hydrochloride and its precursors
    Tam, Rebecca
    Heather, Erin
    Shimmon, Ronald
    Lam, Brandon
    McDonagh, Andrew M.
    FORENSIC SCIENCE INTERNATIONAL, 2017, 272 : 184 - 189
  • [29] Recent trends in impurity profiling and forced degradation of antihypertensive drugs
    Salunkhe, Megha N.
    Gite, Snehal D.
    Kachave, Ramanlal N.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2017, 40 (16) : 813 - 831
  • [30] Determination of impurities in illicit methamphetamine seized in Korea and Japan
    Lee, Jae Sin
    Chung, Hee Sun
    Kuwayama, Kenji
    Inoue, Hiroyuki
    Lee, Mi Young
    Park, Jeong Hill
    ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 20 - 25