Measurements of magnetic field fluctuations using an array of Hall detectors on the TEXTOR tokamak

被引:22
|
作者
Duran, I [1 ]
Stöckel, J
Mank, G
Finken, KH
Fuchs, G
Oost, GV
机构
[1] Inst Plasma Phys, Assoc EURATOM IPPCR, Prague 18221, Czech Republic
[2] Forschungszentrum Julich, EURATOM Assoc, Inst Plasma Phys, TEC Partner, D-52425 Julich, Germany
[3] Univ Ghent, Dept Appl Phys, B-9000 Ghent, Belgium
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2002年 / 73卷 / 10期
关键词
D O I
10.1063/1.1502018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hall detectors have been used to measure the magnetic field together with its' fluctuations in the boundary of a tokamak. The results show, that the measurements which have been performed so far, mainly by use of coils together with subsequent integration, either on-line or later by computer, can be substituted by Hall probe measurements giving the desired value of B directly. Because the integration of the coil signal becomes more and more difficult with long pulses, Hall detectors may give advantages in future fusion devices. We implemented a stack of nine Hall detectors mounted on three planes on a rod in such a way, that the three components of the magnetic field can be measured. To avoid capacitive and charge pickup from the plasma, the probes are electrically shielded. The damping due to skin effect within this shield has been taken into account. The probes have been calibrated using a known magnetic field of a straight wire driven with a LC bank. This field has been precisely measured with a Rogowski coil. The dependence of the Hall coefficient on the frequency has been measured and the pickup in the feeds due to B has been withdrawn from the results. We demonstrate the method with measurements on the TEXTOR tokamak, where we could clearly detect the small stray fields associated with magnetohydrodynamic (MHD) fluctuations. On TEXTOR we have been able to detect the MHD activity preceding discharge disruptions as well as the precursors of the so called sawteeth. The results are compared to those of other diagnostics on TEXTOR as, e.g., magnetic loops and electron cyclotron emission, and they do well compare. (C) 2002 American Institute of Physics.
引用
收藏
页码:3482 / 3489
页数:8
相关论文
共 50 条
  • [41] HALL EFFECT MAGNETIC FIELD INVERTER FOR USE IN FERMI SURFACE MEASUREMENTS
    HIGGINS, RJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (11): : 1536 - &
  • [42] Determination of the resonant harmonics of the error field from dynamic magnetic measurements in a tokamak
    Pustovitov, V. D.
    PLASMA PHYSICS REPORTS, 2008, 34 (01) : 18 - 23
  • [43] Absolute measurements of the magnetic field generated by different coils in the center of EGYPTOR tokamak
    Hegazy, H.
    Zacek, F.
    JOURNAL OF FUSION ENERGY, 2006, 25 (1-2) : 115 - 120
  • [44] High-precision Hall Sensor Array Magnetic Field Measurement System
    Zhang, Jidong
    Zhu, Ya
    Qian, Maofei
    Zhang, Wei
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [45] In-situ analysis of the first wall by laser-induced breakdown spectroscopy in the TEXTOR tokamak: Dependence on the magnetic field strength
    Xiao, Q.
    Hai, R.
    Ding, H.
    Huber, A.
    Philipps, V.
    Gierse, N.
    Sergienko, G.
    JOURNAL OF NUCLEAR MATERIALS, 2015, 463 : 911 - 914
  • [46] Magnetic Communication Using High-Sensitivity Magnetic Field Detectors
    Hott, Maurice
    Hoeher, Peter A.
    Reinecke, Sebastian F.
    SENSORS, 2019, 19 (15)
  • [47] A study of leakage magnetic flux detector using hall sensors array
    Lee, J
    Hwang, J
    Lee, K
    Choi, S
    FRACTURE AND STRENGTH OF SOLIDS VI, PTS 1 AND 2, 2006, 306-308 : 235 - 240
  • [48] Turbulence measurements on the high and low magnetic field side of the DIII-D tokamak
    Sung, C.
    Rhodes, T. L.
    Peebles, W. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [49] Real time magnetic field and flux measurements for tokamak control using a multi-core PCI Express system
    Giannone, L.
    Schneider, W.
    McCarthy, P. J.
    Sips, A. C. C.
    Treutterer, W.
    Behler, K.
    Eich, T.
    Fuchs, J. C.
    Hicks, N.
    Kallenbach, A.
    Maraschek, M.
    Mlynek, A.
    Neu, G.
    Pautasso, G.
    Raupp, G.
    Reich, M.
    Schuhbeck, K. H.
    Stober, J.
    Volpe, F.
    Zehetbauer, T.
    Cerna, M.
    Debelle, T.
    Marker, B.
    McCaslin, S.
    Munroe, M.
    Wenzel, L.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (2-6) : 825 - 828
  • [50] Magnetic Field Correction Factors of high-resolution Semiconductor Detectors using Monte Carlo Simulations and Measurements
    Tekin, T.
    Delfs, B.
    Buesing, I
    Schoenfeld, A. -B
    Kapsch, R. -P
    Poppe, B.
    Looe, H. K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (SUPPL 1) : S66 - S66