Measurements of magnetic field fluctuations using an array of Hall detectors on the TEXTOR tokamak

被引:22
|
作者
Duran, I [1 ]
Stöckel, J
Mank, G
Finken, KH
Fuchs, G
Oost, GV
机构
[1] Inst Plasma Phys, Assoc EURATOM IPPCR, Prague 18221, Czech Republic
[2] Forschungszentrum Julich, EURATOM Assoc, Inst Plasma Phys, TEC Partner, D-52425 Julich, Germany
[3] Univ Ghent, Dept Appl Phys, B-9000 Ghent, Belgium
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2002年 / 73卷 / 10期
关键词
D O I
10.1063/1.1502018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hall detectors have been used to measure the magnetic field together with its' fluctuations in the boundary of a tokamak. The results show, that the measurements which have been performed so far, mainly by use of coils together with subsequent integration, either on-line or later by computer, can be substituted by Hall probe measurements giving the desired value of B directly. Because the integration of the coil signal becomes more and more difficult with long pulses, Hall detectors may give advantages in future fusion devices. We implemented a stack of nine Hall detectors mounted on three planes on a rod in such a way, that the three components of the magnetic field can be measured. To avoid capacitive and charge pickup from the plasma, the probes are electrically shielded. The damping due to skin effect within this shield has been taken into account. The probes have been calibrated using a known magnetic field of a straight wire driven with a LC bank. This field has been precisely measured with a Rogowski coil. The dependence of the Hall coefficient on the frequency has been measured and the pickup in the feeds due to B has been withdrawn from the results. We demonstrate the method with measurements on the TEXTOR tokamak, where we could clearly detect the small stray fields associated with magnetohydrodynamic (MHD) fluctuations. On TEXTOR we have been able to detect the MHD activity preceding discharge disruptions as well as the precursors of the so called sawteeth. The results are compared to those of other diagnostics on TEXTOR as, e.g., magnetic loops and electron cyclotron emission, and they do well compare. (C) 2002 American Institute of Physics.
引用
收藏
页码:3482 / 3489
页数:8
相关论文
共 50 条
  • [1] First results of magnetic turbulence measurements using an array of Hall detectors in the TEXTOR tokamak
    Duran, I
    Stöckel, J
    Mank, G
    Finken, KH
    Fuchs, G
    Van Oost, G
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 : 38 - 44
  • [2] Magnetic measurements using array of integrated Hall sensors on the CASTOR tokamak
    Duran, Ivan
    Hronova, Olena
    Stockel, Jan
    Sentkerestiova, Jana
    Havlicek, Josef
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [3] MEASUREMENTS OF MAGNETIC-FIELD FLUCTUATIONS IN THE CALTECH TOKAMAK
    HEDEMANN, MA
    GOULD, RW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 975 - 975
  • [4] MEASUREMENTS OF MAGNETIC-FIELD FLUCTUATIONS IN CALTECH TOKAMAK
    HEDEMANN, MA
    GOULD, RW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 873 - 873
  • [5] MEASUREMENTS OF MAGNETIC-FIELD FLUCTUATIONS IN THE CALTECH TOKAMAK
    HEDEMANN, MA
    GOULD, RW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1108 - 1108
  • [6] Forced magnetic reconnection and field penetration of an externally applied rotating helical magnetic field in the TEXTOR tokamak
    Kikuchi, Y.
    de Bock, M. F. M.
    Finken, K. H.
    Jakubowski, M.
    Jaspers, R.
    Koslowski, H. R.
    Kraemer-Flecken, A.
    Lehnen, M.
    Liang, Y.
    Matsunaga, G.
    Reiser, D.
    Wolf, R. C.
    Zimmermann, O.
    PHYSICAL REVIEW LETTERS, 2006, 97 (08)
  • [7] Experimental observations of plasma edge magnetic field response to resonant magnetic perturbation on the TEXTOR Tokamak
    Yang, Y.
    Liang, Y.
    Sun, Y.
    Zhang, T.
    Pearson, J.
    Xu, Y.
    NUCLEAR FUSION, 2012, 52 (07)
  • [8] High spatial resolution Hall sensor array for edge plasma magnetic field measurements
    Liu, YH
    Maurer, DA
    Navratil, GA
    Rivera, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09):
  • [9] Specificity of magnetic measurements using the controllable Hall element as a primary magnetic field converter
    Baranochnikov, M. L.
    Leonov, A. V.
    Mokrushin, A. D.
    Mordkovich, V. N.
    Goncharov, V. P.
    Ksenofontov, V. A.
    Filatov, M. M.
    7TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND ELECTROMAGNETIC ECOLOGY, PROCEEDINGS, 2007, : 243 - +
  • [10] Hall Sensor Line Array for Magnetic Field Inline Measurements of PM-exited Rotors
    Tremel, J.
    Franke, J.
    2012 2ND INTERNATIONAL ELECTRIC DRIVES PRODUCTION CONFERENCE (EDPC), 2012,