Dislocation of the rotating platform after low contact stress total knee arthroplasty

被引:39
|
作者
Thompson, NW
Wilson, DS
Cran, GW
Beverland, DE
Stiehl, JB
机构
[1] Musgrave Pk Hosp, Orthopaed Outcomes Unit, Belfast BT9 7JB, Antrim, North Ireland
[2] Queens Univ Belfast, Dept Epidemiol & Publ Hlth, Belfast, Antrim, North Ireland
[3] Columbia Hosp, Columbia Musculoskeletal Inst, Milwaukee, WI USA
关键词
D O I
10.1097/01.blo.0000137295.71245.86
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
From a one-surgeon series of 2485 patients, we report on 10 patients with rotating platform dislocation after primary Low Contact Stress total knee arthroplasty. All dislocations occurred within 2 years of the index procedure. Of the 10 patients, nine required open reduction. Five of these patients also had exchange of the original insert. One patient was treated by closed reduction. All knees were immobilized in a cast for 8 weeks. Eight of the 10 patients had no additional dislocation and at followup (average, 35 months; range, 12 months - 5 years), had a stable functional joint. Two patients had recurrent spinout of the rotating platform develop. One patient had arthrodesis whereas the other patient had the insert cemented to the tibial tray as a salvage procedure. Increasing age, a preoperative valgus deformity, and prior patellectomy were significantly associated with rotating platform spinout. Surgical experience and an improved understanding of the soft tissue constraints, particularly in the valgus knee, are important in minimizing this complication.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 50 条
  • [21] Results of rotating-platform, low-contact-stress knee prosthesis
    Bhan, S
    Malhotra, R
    JOURNAL OF ARTHROPLASTY, 2003, 18 (08): : 1016 - 1022
  • [22] Primary Stability in Cementless Rotating Platform Total Knee Arthroplasty
    Small, Scott R.
    Rogge, Renee D.
    Reyes, Eric M.
    Seale, Ryan B.
    Elliott, Jeffrey B.
    Malinzak, Robert A.
    JOURNAL OF KNEE SURGERY, 2021, 34 (02) : 192 - 199
  • [23] Total knee arthroplasty with modular rotating-platform hinge
    Jones, Richard E.
    ORTHOPEDICS, 2006, 29 (09) : S80 - S82
  • [24] Clinical results of primary Low Contact Stress cementless total knee arthroplasty
    Sorrells, R. Barry
    Capps, Susan G.
    ORTHOPEDICS, 2006, 29 (09) : S42 - S44
  • [25] Comparison of the Low Contact Stress and Press Fit Condylar Rotating-Platform Mobile-Bearing Prostheses in Total Knee Arthroplasty A Prospective Randomized Study
    Kim, Young-Hoo
    Kim, Jun-Shik
    Park, Jang-Won
    Joo, Jong-Hwan
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (11): : 1001 - 1007
  • [26] Total Knee Arthroplasty as the Primary Surgical Treatment After Knee Dislocation
    Gregersen, Mathias Barslund
    Freund, Knud Gade
    ARTHROPLASTY TODAY, 2022, 16 : 112 - 118
  • [27] Management of the severe varus and valgus knee using the low contact stress rotating platform
    Beverland, David
    ORTHOPEDICS, 2006, 29 (09) : S60 - S63
  • [28] Periprosthetic fracture of the tibia associated with osteolysis caused by failure of rotating patella in low-contact-stress total knee arthroplasty
    Watanabe, T
    Tomita, T
    Fujii, M
    Kaneko, M
    Sakaura, H
    Takeuchi, E
    Sugamoto, K
    Yoshikawa, H
    JOURNAL OF ARTHROPLASTY, 2002, 17 (08): : 1058 - 1062
  • [29] Spontaneous dislocation of a mobile-bearing polyethylene insert after posterior-stabilized rotating platform total knee arthroplasty: A case report
    Kobayashi, Hideo
    Akamatsu, Yasushi
    Taki, Naoya
    Ota, Hirohiko
    Mitsugi, Naoto
    Saito, Tomoyuki
    KNEE, 2011, 18 (06): : 496 - 498
  • [30] Anterior dislocation after total knee arthroplasty: a case report
    Tuoheti, Y
    Watanabe, W
    Itoi, E