Evaluation of the Dosimetric Properties of a Synthetic Single Crystal Diamond Detector in Clinical Proton Beams

被引:2
|
作者
Mandapaka, A. [1 ]
Verona-Rinati, G. [2 ]
Ghebremedhin, A. [1 ]
Patyal, B. [1 ]
机构
[1] Loma Linda Univ Med Ctr, Loma Linda, CA USA
[2] Univ Roma Tor Vergata, Rome, Italy
关键词
D O I
10.1118/1.4814539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
下载
收藏
页数:2
相关论文
共 50 条
  • [21] An evaluation of a novel synthetic diamond probe for dosimetric applications
    Ade, N.
    Nam, T. L.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 115 : 97 - 106
  • [22] Investigation of a synthetic diamond detector response in kilovoltage photon beams
    Kaveckyte, Vaiva
    Persson, Linda
    Malusek, Alexandr
    Benmakhlouf, Hamza
    Carlsson, Gudrun Alm
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2020, 47 (03) : 1268 - 1279
  • [23] On the Dose Response Function and the Energy Dependence of a Novel Synthetic Single Crystal Diamond Detector
    Looe, H. K.
    Chofor, N.
    Harmeyer, A.
    Poppinga, D.
    Schoenfeld, A.
    Grabowski, D.
    Willborn, K.
    Harder, D.
    Poppe, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system
    Mancosu, Pietro
    Reggiori, Giacomo
    Stravato, Antonella
    Gaudino, Anna
    Lobefalo, Francesca
    Palumbo, Valentina
    Navarria, Piera
    Ascolese, Anna
    Picozzi, Piero
    Marinelli, Marco
    Verona-Rinati, Gianluca
    Tomatis, Stefano
    Scorsetti, Marta
    MEDICAL PHYSICS, 2015, 42 (09) : 5035 - 5041
  • [25] Investigation of Dosimetric Characteristics of a MOSFET Detector for Clinical Electron Beams
    Dinc, Serap Catli
    Hancer, Ceren
    Demirci, Temur
    Akmansu, Muge
    GAZI MEDICAL JOURNAL, 2019, 30 (01): : 48 - 51
  • [26] Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams
    Manuel Larraga-Gutierrez, Jose
    Ballesteros-Zebadua, Paola
    Rodriguez-Ponce, Miguel
    Amanda Garcia-Garduno, Olivia
    Galvan de la Cruz, Olga Olinca
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 905 - 924
  • [27] Dosimetric characterization of silicon and diamond detectors in low-energy proton beams
    Onori, S
    De Angelis, C
    Fattibene, P
    Pacilio, M
    Petetti, E
    Azario, L
    Miceli, R
    Piermattei, A
    Tonghi, LB
    Cuttone, G
    Lo Nigro, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10): : 3045 - 3058
  • [28] Absolute Dosimetry with a Single Crystal Diamond Detector
    Manohar, N.
    Wang, T.
    Jiang, X.
    Dresser, S.
    Siddiqi, A.
    Liu, T.
    Dhabaan, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E310 - E310
  • [29] Optimized Design of a Diamond Detector Specifically Dedicated to the Dose Distribution Measurements in Clinical Proton Pencil Beams
    Moignier, C.
    Tromson, D.
    Marsolat, F.
    De Marzi, L.
    Pomorski, M.
    Agelou, M.
    Hernandez, J. Garcia
    Lazaro, D.
    Mazal, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3502 - 3502
  • [30] Dosimetric properties of a newly developed thermoluminescent sheet-type dosimeter for clinical proton beams
    Kato, Takahiro
    Sagara, Tatsuhiko
    Komori, Shinya
    Kato, Ryohei
    Takeuchi, Akihiko
    Narita, Yuki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (04): : 158 - 165