摘要
PurposeRenal dynamic contrast-enhanced (DCE) MRI provides information on renal perfusion and filtration. However, clinical implementation is hampered by challenges in postprocessing as a result of misalignment of the kidneys due to respiration. We propose to perform automated image registration using the fat-only images derived from a modified Dixon reconstruction of a dual-echo acquisition because these provide consistent contrast over the dynamic series. MethodsDCE data of 10 hypertensive patients was used. Dual-echo images were acquired at 1.5T with temporal resolution of 3.9 s during contrast agent injection. Dixon fat, water, and in-phase and opposed-phase (OP) images were reconstructed. Postprocessing was automated. Registration was performed both to fat images and OP images for comparison. Perfusion and filtration values were extracted from a two-compartment model fit. ResultsAutomatic registration to fat images performed better than automatic registration to OP images with visible contrast enhancement. Median vertical misalignment of the kidneys was 14mm prior to registration, compared to 3mm and 5mm with registration to fat images and OP images, respectively (P=0.03). Mean perfusion values and MR-based glomerular filtration rates (GFR) were 23364mL/100mL/min and 60 +/- 36mL/minute, respectively, based on fat-registered images. MR-based GFR correlated with creatinine-based GFR (P=0.04) for fat-registered images. For unregistered and OP-registered images, this correlation was not significant. ConclusionAbsence of contrast changes on Dixon fat images improves registration in renal DCE MRI and enables automated postprocessing, resulting in a more accurate estimation of GFR. Magn Reson Med 80:66-76, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
引用
收藏
页码:66 / 76
页数:11
相关论文
共 50 条
  • [21] Contrast-enhanced ultrasound analysis of renal perfusion in normal micropigs
    Yi, Kangjae
    Ji, Seoyeoun
    Kim, Junyoung
    Yoon, Junghee
    Choi, Mincheol
    JOURNAL OF VETERINARY SCIENCE, 2012, 13 (03) : 311 - 314
  • [22] Exploratory data analysis of dynamic cerebral contrast-enhanced perfusion MRI time-series
    Lange, O
    Meyer-Baese, A
    Wismueller, A
    Proceedings of the International Joint Conference on Neural Networks (IJCNN), Vols 1-5, 2005, : 2406 - 2410
  • [23] De-enhancing the dynamic contrast-enhanced breast MRI for robust registration
    Zheng, Yuanjie
    Yu, Jingyi
    Kambhamettu, Chandra
    Englander, Sarah
    Schnall, Mitchell D.
    Shen, Dinggang
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 933 - +
  • [24] A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney
    Merrem, Andreas D.
    Zoellner, Frank G.
    Reich, Marcel
    Lundervold, Arvid
    Rorvik, Jarle
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (05) : 771 - 777
  • [25] On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies
    Di Bella, EVR
    Parker, DL
    Sinusas, AJ
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1295 - 1299
  • [26] Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI
    Mistry, Nilesh N.
    Pollaro, James
    Song, Jiayu
    De Lin, Ming
    Johnson, G. Allan
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 289 - 297
  • [27] System identification theory in myocardial perfusion modeling of dynamic contrast-enhanced MRI
    Jean-Paul Vallée
    Marko Ivancevic
    Jean-Luc Daire
    Dominique Didier
    Michel Kocher
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [28] Comparison of Glioblastomas and Brain Metastases using Dynamic Contrast-Enhanced Perfusion MRI
    Jung, Brian C.
    Arevalo-Perez, Julio
    Lyo, John K.
    Holodny, Andrei I.
    Karimi, Sasan
    Young, Robert J.
    Peck, Kyung K.
    JOURNAL OF NEUROIMAGING, 2016, 26 (02) : 240 - 246
  • [29] Repeatability of tumor perfusion kinetics from dynamic contrast-enhanced MRI in glioblastoma
    Woodall, Ryan T.
    Sahoo, Prativa
    Cui, Yujie
    Chen, Bihong T.
    Shiroishi, Mark S.
    Lavini, Cristina
    Frankel, Paul
    Gutova, Margarita
    Brown, Christine E.
    Munson, Jennifer M.
    Rockne, Russell C.
    NEURO-ONCOLOGY ADVANCES, 2021, 3 (01)
  • [30] Modified MR dispersion imaging in prostate dynamic contrast-enhanced MRI
    Sung, Kyunghyun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1307 - 1317