This communication shows a novel strategy in the field of potentiometric sensors, applied to the determination of nitrate in the presence of chloride interferent. The determination is performed employing the flow-injection analysis technique with four potentiometric sensors featuring cross-term response. The signal processing with a multivariate data treatment, in this case an artificial neural network based on the Bayesian regularization, lets us quantify the concentration of nitrate ion between 0.1 and 100 mg l(-1) NO3- without the need to eliminate chloride interferent. Results obtained with this approach are compared with the direct determination of nitrate using its ion-selective electrode, showing how the new strategy attains a better correlation of obtained versus expected values, especially at the lower concentration levels. The comparison line between these pairs yields an intercept of 0.0 +/- 0.3 mg l(-1) NO3- and a slope of 1.01 +/- 0.02. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [21] Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture
    Cortina, Montserrat
    Ecker, Christina
    Calvo, Daniel
    del Valle, Manuel
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (02) : 213 - 218
  • [22] FLOW-INJECTION DETERMINATION OF COPPER IN CONCENTRATED ELECTROLYTES WITH POTENTIOMETRIC DETECTION
    KRAWCZYK, TKV
    TROJANOWICZ, M
    HULANICKI, A
    CHEMIA ANALITYCZNA, 1988, 33 (01): : 69 - 74
  • [23] FLOW-INJECTION ANALYSIS - POTENTIOMETRIC DETERMINATION OF COPPER(II) IN WATERS
    SHPIGUN, LK
    BAZANOVA, OV
    KUZMIN, NM
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (12): : 1790 - 1795
  • [24] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS
    GINE, MF
    BERGAMIN, H
    ZAGATTO, EAG
    REIS, BF
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 191 - 197
  • [25] DETERMINATION OF NITRATE AND NITRITE IN SEAWATER BY FLOW-INJECTION ANALYSIS
    JOHNSON, KS
    PETTY, RL
    LIMNOLOGY AND OCEANOGRAPHY, 1983, 28 (06) : 1260 - 1266
  • [26] Potentiometric determination of chloride in vegetables by flow injection analysis
    Lima, JLFC
    Rangel, AOSS
    Souto, MRS
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1996, 27 (1-2) : 37 - 46
  • [27] Potentiometric flow-injection determination of cysteine in the presence of cystine using a tubular electrode with Ag(I)-based membrane as detector
    Komljenovic, J
    Radic, N
    ANALUSIS, 1996, 24 (03) : 63 - 65
  • [28] Flow-injection potentiometric determination of trace concentrations of chloride ions in low-mineralized natural waters
    E. V. Telegina
    A. L. Moskvin
    A. V. Mozzhukhin
    Journal of Analytical Chemistry, 2010, 65 : 1041 - 1044
  • [29] Flow-injection potentiometric determination of trace concentrations of chloride ions in low-mineralized natural waters
    Telegina, E. V.
    Moskvin, A. L.
    Mozzhukhin, A. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (10) : 1041 - 1044
  • [30] An 'electronic tongue' system based on an array of metallic potentiometric sensors
    Lvova, L
    De Angelis, G
    Montieri, C
    Primadei, T
    Martinelli, E
    Mazzone, E
    Pede, A
    Paolesse, R
    Di Natale, C
    D'Amico, A
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 233 - 235