The DeBakey ventricular assist device:: Current status in 1997

被引:19
|
作者
Tayama, E
Olsen, DB
Ohashi, Y
Benkowski, R
Morley, D
Noon, GP
Nosé, Y
DeBakey, ME
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Univ Utah, Artificial Heart Res Lab, Salt Lake City, UT USA
[3] MicroMed Technol Inc, Woodlands, TX USA
关键词
artificial hearts; ventricular assist device; axial flow blood pump; implantable device; DeBakey ventricular assist device;
D O I
10.1046/j.1525-1594.1999.06300.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In 1993, the development began of a small axial now blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. Nine animals survived the 2 week perioperative period and were supported for a range of 26-93 days. The first study had low flow due to poor anatomical fit of the straight cannula. In contrast, a curved cannula used subsequently provided a good anatomical fit with sufficient flow. Mean flow of 4.4 L/min was sustained with 9,900 rpm and required power was an average of 8.8 W. No thromboembolic evidences were observed in any case, and the plasma free hemoglobin bin level was maintained lower than 5 mg/dl, except in the early postoperative period. Three animals were terminated because of bleeding due to anticoagulant mismanagement. Electric interference (n = 1) and drive line breakage/fault (n = 2) were observed as device-related failures. Minor modifications were made to the drive line. in conclusion, the DeBakey VAD demonstrated adequate basic: performance and biocompatibility. The highly reliable mechanical components and improved electrical parts are promising for a long-term implantable cardiac prosthesis.
引用
收藏
页码:1113 / 1116
页数:4
相关论文
共 50 条
  • [1] Current Status of the MicroMed DeBakey Noon Ventricular Assist Device
    Noon, George P.
    Loebe, Matthias
    TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (06) : 652 - 653
  • [2] Current status of the use of ventricular assist device
    Kanebako, Hideki
    Journal of the Institute of Electrical Engineers of Japan, 2015, 135 (09): : 610 - 612
  • [3] Clinical experience with the MicroMed DeBakey ventricular assist device
    Noon, GP
    Morley, DL
    Irwin, S
    Abdelsayed, SV
    Benkowski, RJ
    Lynch, BE
    ANNALS OF THORACIC SURGERY, 2001, 71 (03): : S133 - S138
  • [4] Current Status of Left Ventricular Assist Device Therapy
    Sajgalik, Pavol
    Grupper, Avishay
    Edwards, Brook S.
    Kushwaha, Sudhir S.
    Stulak, John M.
    Joyce, David L.
    Joyce, Lyle D.
    Daly, Richard C.
    Kara, Tomas
    Schirger, John A.
    MAYO CLINIC PROCEEDINGS, 2016, 91 (07) : 927 - 940
  • [5] Current Status of Left Ventricular Assist Device Technology
    Molina, Ezequiel J.
    Boyce, Steven W.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2013, 25 (01) : 56 - 63
  • [6] Suction detection for the MicroMed DeBakey left ventricular assist device
    Voigt, O
    Benkowski, RJ
    Morello, GF
    ASAIO JOURNAL, 2005, 51 (04) : 321 - 328
  • [7] Chronic survival of calves implanted with the DeBakey ventricular assist device
    Fossum, TW
    Morley, D
    Benkowski, R
    Tayama, E
    Olsen, DB
    Burns, G
    Miller, MW
    Franks, J
    Martinez, E
    Carroll, G
    Edwards, J
    Vinnerqvist, A
    Lynch, B
    Stein, F
    Noon, GP
    DeBakey, ME
    ARTIFICIAL ORGANS, 1999, 23 (08) : 802 - 806
  • [8] Current status and future directions in pediatric ventricular assist device
    Huang, Xu
    Shen, Yi
    Liu, Yiwei
    Hao, Zhang
    HEART FAILURE REVIEWS, 2024, 29 (04) : 769 - 784
  • [9] Worldwide experience with the MicroMed DeBakey Ventricular Assist device as a bridge to transplantation
    Goldstein, DJ
    Noon, G
    Hetzer, R
    Scheld, H
    Wolner, E
    CIRCULATION, 2002, 106 (19) : 607 - 607
  • [10] Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation
    Goldstein, DJ
    CIRCULATION, 2003, 108 (10) : 272 - 277