Suction detection for the MicroMed DeBakey left ventricular assist device

被引:34
|
作者
Voigt, O [1 ]
Benkowski, RJ [1 ]
Morello, GF [1 ]
机构
[1] MicroMed Technol Inc, Houston, TX USA
关键词
D O I
10.1097/01.mat.0000169118.21639.da
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The MicroMed DeBakey Ventricular Assist Device (MicroMed Technology, Inc., Houston, TX) is a continuous axial flow pump designed for long-term circulatory support. The system received CE approval in 2001 as a bridge to transplantation and in 2004 as an alternative to transplantation. Low volume in the left ventricle or immoderate pump speed may cause ventricular collapse due to excessive suction. Suction causes decreased flow and may result in patient discomfort. Therefore, detection of this critical condition and immediate adaptive control of the device is desired. The purpose of this study is to evaluate and validate system parameters suitable for the reliable detection of suction. In vitro studies have been performed with a mock loop allowing pulsatile and nonpulsatile flow. Evidence of suction is clearly shown by the flow waveform reported by the implanted flow probe of the system. For redundancy to the implanted flow probe, it would be desirable to use the electronic motor signals of the pump for suction detection. The continuously accessible signals are motor current consumption and rotor/impeller speed. The influence of suction on these parameters has been investigated over a wide range of hydrodynamic conditions, and the significance of the respective signals individually or in combination has been explored. The reference signal for this analysis was the flow waveform of the ultrasonic probe. To achieve high reliability under both pulsatile and nonpulsatile conditions, it was determined that motor speed and current should be used concurrently for suction detection. Using the amplified differentiated current and speed signals, a suction-detection algorithm has been optimized, taking into account two different working points, defined by the value of the current input. The safety of this algorithm has been proven in vitro under pulsatile and nonpulsatile conditions over the full spectrum of possible speed and differential pressure variations. The algorithm described herein may be best utilized to provide redundancy to the existing flow based algorithm.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 50 条
  • [1] Clinical experience with the MicroMed DeBakey ventricular assist device
    Noon, GP
    Morley, DL
    Irwin, S
    Abdelsayed, SV
    Benkowski, RJ
    Lynch, BE
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03): : S133 - S138
  • [2] Current Status of the MicroMed DeBakey Noon Ventricular Assist Device
    Noon, George P.
    Loebe, Matthias
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (06) : 652 - 653
  • [3] Worldwide experience with the MicroMed DeBakey Ventricular Assist device as a bridge to transplantation
    Goldstein, DJ
    Noon, G
    Hetzer, R
    Scheld, H
    Wolner, E
    [J]. CIRCULATION, 2002, 106 (19) : 607 - 607
  • [4] Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation
    Goldstein, DJ
    [J]. CIRCULATION, 2003, 108 (10) : 272 - 277
  • [5] Safety and feasibility trial of the micromed DeBakey ventricular assist device as a bridge to transplantation
    Goldstein, DJ
    Zucker, M
    Arroyo, L
    Baran, D
    McCarthy, PM
    Loebe, M
    Noon, GP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) : 962 - 963
  • [6] Outcomes of patients with right ventricular dysfunction following insertion of MicroMed DeBakey ventricular assist device
    Velez-Pestana, L
    Herrera, E
    Loebe, M
    Roberts, R
    Singh, K
    Pekkattil, J
    [J]. ANESTHESIA AND ANALGESIA, 2004, 98 (04): : 134 - 134
  • [7] Successful experience in bridging patients to heart transplantation with the MicroMed DeBakey ventricular assist device
    Vitali, E
    Lanfranconi, M
    Ribera, E
    Bruschi, G
    Colombo, T
    Frigerio, M
    Russo, C
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (04): : 1200 - 1204
  • [8] Left ventricular assist device as bridge to heart transplantation -: lessons learned with the MicroMed DeBakey axial blood flow pump
    Salzberg, S
    Lachat, M
    Zünd, G
    Oechslin, E
    Schmid, ER
    DeBakey, M
    Turina, M
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (01) : 113 - 118
  • [9] Special considerations on the implantation technique for the MicroMed-DeBakey ventricular assist device axial pump
    Wieselthaler, GM
    Schima, H
    Wolner, E
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (06): : 2109 - 2111
  • [10] Bridge to transplant using the MicroMed DeBakey ventricular assist device in a child with idiopathic dilated cardiomyopathy
    Padalino, MA
    Ohye, RG
    Chang, AC
    Gajarski, RJ
    Bove, EL
    Devaney, EJ
    [J]. ANNALS OF THORACIC SURGERY, 2006, 81 (03): : 1118 - 1121