Left ventricular assist device as bridge to heart transplantation -: lessons learned with the MicroMed DeBakey axial blood flow pump

被引:32
|
作者
Salzberg, S [1 ]
Lachat, M
Zünd, G
Oechslin, E
Schmid, ER
DeBakey, M
Turina, M
机构
[1] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Cardiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Clin Anaesthesiol, CH-8091 Zurich, Switzerland
[4] Baylor Coll Med, Houston, TX 77030 USA
关键词
terminal heart failure; axial blood flow; heart transplantation; left ventricular assist device; mechanical circulatory support;
D O I
10.1016/S1010-7940(03)00179-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The MicroMed DeBakey left ventricular assist device (LVAD) axial blood flow pump was used as bridge to heart transplantation (HTx) in patients with terminal heart failure. The aim was to evaluate this novel mechanical circulatory support system in regard to overall outcome. Methods: Prospective study in 15 HTx candidates (mean age 40 +/- 7 years) with terminal heart failure and maximal medical treatment due to ischemic cardiomyopathy (CMP, it = 5), dilated CMP (n = 3), restrictive CMP (n = 2), unclassified CMP (n = 1), metabolic CMP (n = 1), valvutar CMP (n = 1) and congenital CMP (n = 2). All patients were implanted with a MicroMed DeBakey LVAD. A rescue procedure was necessary in eight critical patients, while seven underwent elective LVAD implantation. Procedures were performed via median sternotomy, in normotherm femoro-femoral CPB (mean duration 59 +/- 1 min). Oral Marcoumaro((C)) (INR 2.0-3.0) and Aspirin(C) (100 mg daily) were started as soon as possible. Patients were discharged into a specialized rehabilitation clinic from which it was possible to release them home after a few weeks. Results: Successful implantation and discharge from ICU (mean stay 10 7 days) was possible in 11 patients. Seven were transplanted (mean support 50.7 days) and one is awaiting HTx (support >310 days) in the comfort of his home (NYHA I). Survival was 100% among the transplanted patients. Of the seven elective implants, five, and of the eight rescue procedures three patients underwent successful HTx. Four patients died early, while three patients died late on pump support due to intracranial hemorrhage (17 = 21 73 and 76 days) and chest infection (it = 1, 124 days). All survivors were discharged from hospital, with sianificant decrease in NYHA class (mean 3.8-2.4 (n = 11)). Treadmill testing showed increased exercise tolerance, from 35 to 71 W (n = 4). Plasma BNP values (mean 950-162 ng/l (n = 4)) and pulmonary resistance (mean 316-194.5 dyne S/cm(5) (n = 3)) decreased significantly during LVAD support. Conclusions: The MicroMed DeBakey LVAD is simple to implant; outpatient treatment is safe and efficient. Patients' condition and pulmonary resistances normalize within 6 weeks, making previously considered inoperable patients amenable for HTx. HTx can be performed in low-risk situation, allowing better donor-recipient matching and improving overall outcome. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [1] Bridge to transplantation with the MicroMed DeBakey ventricular assist device axial pump: a single centre report
    Bruschi, Giuseppe
    Ribera, Elena
    Lanfranconi, Marco
    Russo, Claudio
    Colombo, Tiziano
    Garatti, Andrea
    Oliva, Fabrizio
    Milazzo, Filippo
    Frigerio, Maria
    Vitali, Ettore
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (02) : 114 - 118
  • [2] Worldwide experience with the MicroMed DeBakey Ventricular Assist device as a bridge to transplantation
    Goldstein, DJ
    Noon, G
    Hetzer, R
    Scheld, H
    Wolner, E
    [J]. CIRCULATION, 2002, 106 (19) : 607 - 607
  • [3] Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation
    Goldstein, DJ
    [J]. CIRCULATION, 2003, 108 (10) : 272 - 277
  • [4] Safety and feasibility trial of the micromed DeBakey ventricular assist device as a bridge to transplantation
    Goldstein, DJ
    Zucker, M
    Arroyo, L
    Baran, D
    McCarthy, PM
    Loebe, M
    Noon, GP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) : 962 - 963
  • [5] Suction detection for the MicroMed DeBakey left ventricular assist device
    Voigt, O
    Benkowski, RJ
    Morello, GF
    [J]. ASAIO JOURNAL, 2005, 51 (04) : 321 - 328
  • [6] Special considerations on the implantation technique for the MicroMed-DeBakey ventricular assist device axial pump
    Wieselthaler, GM
    Schima, H
    Wolner, E
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (06): : 2109 - 2111
  • [7] Successful experience in bridging patients to heart transplantation with the MicroMed DeBakey ventricular assist device
    Vitali, E
    Lanfranconi, M
    Ribera, E
    Bruschi, G
    Colombo, T
    Frigerio, M
    Russo, C
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (04): : 1200 - 1204
  • [8] Inflammatory response after implantation of a left ventricular assist device:: Comparison between the axial flow MicroMed DeBakey VAD and the pulsatile Novacor device
    Loebe, M
    Koster, A
    Sänger, S
    Potapov, EV
    Kuppe, H
    Noon, GP
    Hetzer, R
    [J]. ASAIO JOURNAL, 2001, 47 (03) : 272 - 274
  • [9] Lessons learned from the first clinical implants of the DeBakey ventricular assist device axial pump: A single center report
    Wieselthaler, GM
    Schima, H
    Lassnigg, AM
    Dworschak, M
    Pacher, R
    Grimm, M
    Wolner, E
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03): : S139 - S143
  • [10] Left ventricular assist device therapy with the HeartMate II continuous flow rotary pump as a bridge to heart transplantation
    Pagani, Francis D.
    Miller, Leslie W.
    Russell, Stuart D.
    John, Ranjit
    Boyle, Andrew J.
    Aaronson, Keith D.
    Conte, John V.
    Naka, Yoshifumi
    Mancini, Donna
    Delgado, Reynolds M.
    MacGillivray, Thomas E.
    Farrar, David J.
    Frazier, O. H.
    [J]. CIRCULATION, 2007, 116 (16) : 540 - 541