Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen A Randomized Controlled Trial

被引:3
|
作者
Martens, Bibi [1 ,2 ]
Wildberger, Joachim E. [1 ,2 ]
Van Kuijk, Sander M. J. [3 ]
De Vos-Geelen, Judith [4 ,5 ]
Jeukens, Cecile R. L. P. N. [1 ]
Mihl, Casper [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25 POB 5800, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
[4] Maastricht UMC, Div Med Oncol, Dept Internal Med, Maastricht, Netherlands
[5] Maastricht UMC, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
关键词
multidetector computed tomography; diagnostic imaging; abdomen; contrast media; image quality; contrast material warming; discomfort; HEPATIC DYNAMIC CT; MEDIA VISCOSITY; ANGIOGRAPHY; ENHANCEMENT; INJECTION; FLOW;
D O I
10.1097/RLI.0000000000000807
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: International guideline recommendations on safe use of contrast media (CM) are conflicting regarding the necessity to prewarm iodinated CM. Purpose: Aim of the study was to evaluate the effects of room temperature CM compared with prewarmed CM on image quality, safety, and patient comfort in abdominal computed tomography (CT). Methods: CATCHY (Contrast Media Temperature and Patient Comfort in Computed Tomography of the Abdomen) is a double-blinded, randomized noninferiority trial. Between February and August 2020, 218 participants referred for portal venous abdominal CTwere prospectively and randomly assigned to 1 of 2 groups. All patients received iopromide at 300 mg I/mL: group 1 at room temperature (similar to 23 degrees C [similar to 73 degrees F]) and group 2 prewarmed to body temperature (37 degrees C [99 degrees F]). A state-of-the-art individualized CM injection protocol was used, based on body weight and adapted to tube voltage. Primary outcome was absolute difference in mean liver attenuation between groups, calculated with a 2-sided 95% confidence interval. The noninferiority margin was set at -10 HU. Secondary outcomes were objective (signal-to-noise ratio and contrast-to-noise ratio) and subjective image quality; CMextravasations and other adverse events; and participant comfort (5-point scale questionnaire) and pain (numeric rating scale). This trial is registered with ClinicalTrials.gov (NCT04249479). Results: The absolute difference in mean attenuation between groups was + 4.23 HU (95% confidence interval, +0.35 to +8.11; mean attenuation, 122.2 +/- 13.1 HU in group 1, 118.0 +/- 15.9 HU in group 2; P = 0.03). Signalto-noise ratio, contrast-to-noise ratio, and subjective image quality were not significantly different between groups (P = 0.53, 0.23, and 0.99 respectively). Contrast extravasation occurred in 1 patient (group 2), and no other adverse events occurred. Comfort scores were significantly higher in group 1 than in group 2 (P = 0.03); pain did not significantly differ (perceived P > 0.99; intensity P = 0.20). Conclusions: Not prewarming iodinated CM was found noninferior in abdominal CT imaging. Prewarming conferred no beneficial effect on image quality, safety, and comfort, and might therefore no longer be considered a prerequisite in state-of-the art injection protocols for parenchymal imaging.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [21] Fine focal spot size improves image quality in computed tomography abdomen and pelvis
    Goh, Yin P.
    Lau, Kenneth K.
    Low, Keat
    Buchan, Kevin
    Oh, Lawrence Chia Wei
    Kuganesan, Ahilan
    Huynh, Minh
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4545 - 4550
  • [22] Patient-tailored Contrast Delivery Protocols for Computed Tomography Coronary Angiography Lower Contrast Dose and Better Image Quality
    van den Boogert, Thomas P. W.
    Lopes, Ricardo R.
    Lobe, Nick H. J.
    Verwest, Tim A.
    Stoker, Jaap
    Henriques, Jose P.
    Marquering, Henk A.
    Planken, R. Nils
    JOURNAL OF THORACIC IMAGING, 2021, 36 (06) : 353 - 359
  • [23] IMAGE QUALITY AND PATIENT DOSE IN COMPUTED TOMOGRAPHY EXAMINATIONS IN GREECE
    Simantirakis, G.
    Hourdakis, C. J.
    Economides, S.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 129 - 132
  • [24] Managing patient comfort during dermatologic procedures: A randomized controlled trial
    Yanes, Arianna
    Furlan, Karina Colossi
    Weil, Alexandra
    Poon, Emily
    Alam, Murad
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2018, 79 (03) : AB186 - AB186
  • [25] Diagnostic Accuracy of Computed Tomography Pulmonary Angiography With Reduced Radiation and Contrast Material Dose A Prospective Randomized Clinical Trial
    Szucs-Farkas, Zsolt
    Christe, Andreas
    Megyeri, Boglarka
    Rohacek, Martin
    Vock, Peter
    Nagy, Endre V.
    Heverhagen, Johannes T.
    Schindera, Sebastian T.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (04) : 201 - 208
  • [26] Halved contrast medium dose in lower limb dual-energy computed tomography angiography—a randomized controlled trial
    Cathrine Helgestad Kristiansen
    Owen Thomas
    Thien Trung Tran
    Sumit Roy
    Dan Levi Hykkerud
    Audun Sanderud
    Jonn Terje Geitung
    Peter M. Lauritzen
    European Radiology, 2023, 33 : 6033 - 6044
  • [27] INtravenous Contrast computed tomography versus native computed tomography in patients with acute Abdomen and impaired Renal functiOn (INCARO): a multicentre, open-label, randomised controlled trial - study protocol
    Raty, Panu
    Mentula, Panu
    Lampela, Hanna
    Nykanen, Taina
    Helantera, Ilkka
    Haapio, Mikko
    Lehtimaki, Tiina
    Skrifvars, Markus B.
    Vaara, Suvi T.
    Leppaniemi, Ari
    Sallinen, Ville
    BMJ OPEN, 2020, 10 (10):
  • [28] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [29] Influence of exposure parameters on patient dose and image noise in computed tomography
    Stoyanov, Desislav
    Vassileva, Jenia
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2009, 15 (04): : 215 - 226
  • [30] Abdomen CT: Influence of patient size and technical factors on image noise and quality
    Tsapaki, V
    Triantopoulou, C
    Maniatis, P
    Siafas, I
    Tsalafoutas, I
    Priniotaki, A
    Papailiou, J
    Rehani, M
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF RADIOLOGY OF THE INTERNATIONAL SOCIETY OF RADIOLOGY, 2004, : 647 - 650