Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen A Randomized Controlled Trial

被引:3
|
作者
Martens, Bibi [1 ,2 ]
Wildberger, Joachim E. [1 ,2 ]
Van Kuijk, Sander M. J. [3 ]
De Vos-Geelen, Judith [4 ,5 ]
Jeukens, Cecile R. L. P. N. [1 ]
Mihl, Casper [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25 POB 5800, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
[4] Maastricht UMC, Div Med Oncol, Dept Internal Med, Maastricht, Netherlands
[5] Maastricht UMC, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
关键词
multidetector computed tomography; diagnostic imaging; abdomen; contrast media; image quality; contrast material warming; discomfort; HEPATIC DYNAMIC CT; MEDIA VISCOSITY; ANGIOGRAPHY; ENHANCEMENT; INJECTION; FLOW;
D O I
10.1097/RLI.0000000000000807
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: International guideline recommendations on safe use of contrast media (CM) are conflicting regarding the necessity to prewarm iodinated CM. Purpose: Aim of the study was to evaluate the effects of room temperature CM compared with prewarmed CM on image quality, safety, and patient comfort in abdominal computed tomography (CT). Methods: CATCHY (Contrast Media Temperature and Patient Comfort in Computed Tomography of the Abdomen) is a double-blinded, randomized noninferiority trial. Between February and August 2020, 218 participants referred for portal venous abdominal CTwere prospectively and randomly assigned to 1 of 2 groups. All patients received iopromide at 300 mg I/mL: group 1 at room temperature (similar to 23 degrees C [similar to 73 degrees F]) and group 2 prewarmed to body temperature (37 degrees C [99 degrees F]). A state-of-the-art individualized CM injection protocol was used, based on body weight and adapted to tube voltage. Primary outcome was absolute difference in mean liver attenuation between groups, calculated with a 2-sided 95% confidence interval. The noninferiority margin was set at -10 HU. Secondary outcomes were objective (signal-to-noise ratio and contrast-to-noise ratio) and subjective image quality; CMextravasations and other adverse events; and participant comfort (5-point scale questionnaire) and pain (numeric rating scale). This trial is registered with ClinicalTrials.gov (NCT04249479). Results: The absolute difference in mean attenuation between groups was + 4.23 HU (95% confidence interval, +0.35 to +8.11; mean attenuation, 122.2 +/- 13.1 HU in group 1, 118.0 +/- 15.9 HU in group 2; P = 0.03). Signalto-noise ratio, contrast-to-noise ratio, and subjective image quality were not significantly different between groups (P = 0.53, 0.23, and 0.99 respectively). Contrast extravasation occurred in 1 patient (group 2), and no other adverse events occurred. Comfort scores were significantly higher in group 1 than in group 2 (P = 0.03); pain did not significantly differ (perceived P > 0.99; intensity P = 0.20). Conclusions: Not prewarming iodinated CM was found noninferior in abdominal CT imaging. Prewarming conferred no beneficial effect on image quality, safety, and comfort, and might therefore no longer be considered a prerequisite in state-of-the art injection protocols for parenchymal imaging.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [1] Comparison of patient comfort between iodixanol and iopamidol in contrast-enhanced computed tomography of the abdomen and pelvis: a randomized trial
    Weiland, Frederick L.
    Marti-Bonmati, Luis
    Lim, Lauren
    Becker, Hans-Christoph
    ACTA RADIOLOGICA, 2014, 55 (06) : 715 - 724
  • [2] Influence of Contrast Media Temperature and Concentration on Patient Comfort and Safety in Computed Tomography
    Stammen, Lion
    Mihl, Casper
    Vandewall, Janneke
    Pennetta, Francesca
    Hersbach, Ankie
    Wildberger, Joachim E.
    Martens, Bibi
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 577 - 582
  • [3] Image quality and patient satisfaction in cone-beam and multidetector computed tomography of the wrist: a randomized trial
    Reidelbach, Carolin S.
    Neubauer, Claudia
    Geissler, Ann-Kristin H.
    Lampert, Florian
    Zajonc, Horst
    Simunovic, Filip
    Bamberg, Fabian
    Kotter, Elmar
    Goerke, Sebastian M.
    Neubauer, Jakob
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [4] Screening for occult malignancy in patient with unprovoked venous thromboembolism: an open randomized controlled trial using a comprehensive abdomen/pelvis computed tomography (some trial)
    Carrier, M.
    Lazo-Langner, A.
    Shivakumar, S.
    Tagalakis, V
    Zarychanski, R.
    Solymoss, S.
    Routhier, N.
    Douketis, J.
    Danovitch, K.
    Lee, A. Y.
    Gal, G. L.
    Wells, P. S.
    Ramsay, T.
    Coyle, D.
    Chagnon, I
    Kassam, Z.
    Taves, D.
    Rodger, M. A.
    Tao, H.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 : 83 - 83
  • [5] Clinical assessment of image quality, usability and patient comfort in dedicated spiral breast computed tomography
    Schmidt, Cynthia Sabrina
    Zellweger, Caroline
    Wieler, Jann
    Berger, Nicole
    Marcon, Magda
    Frauenfelder, Thomas
    Boss, Andreas
    CLINICAL IMAGING, 2022, 90 : 50 - 58
  • [6] Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial
    Im, Dong Jin
    Kim, Yun-Hyeon
    Choo, Ki Seok
    Kang, Joon-Won
    Jung, Jung Im
    Won, Yoodong
    Kim, Hyo Rim
    Chung, Myung Hee
    Han, Kyunghwa
    Choi, Byoung Wook
    TRIALS, 2016, 17
  • [7] Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial
    Dong Jin Im
    Yun-Hyeon Kim
    Ki Seok Choo
    Joon-Won Kang
    Jung Im Jung
    Yoodong Won
    Hyo Rim Kim
    Myung Hee Chung
    Kyunghwa Han
    Byoung Wook Choi
    Trials, 17
  • [8] Is positive oral contrast material necessary for computed tomography in patients with suspected acute abdomen?
    Gonzalez-Moreno, I. M.
    Plasencia-Martinez, J. M.
    Blanco-Barrio, A.
    Moreno-Pastor, A.
    RADIOLOGIA, 2019, 61 (02): : 161 - 166
  • [9] PATIENT DOSE AND IMAGE QUALITY IN COMPUTED-TOMOGRAPHY
    TREFLER, M
    HAUGHTON, VM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1981, 2 (03) : 269 - 271
  • [10] PATIENT DOSE AND IMAGE QUALITY IN COMPUTED-TOMOGRAPHY
    TREFLER, M
    HAUGHTON, VM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (01) : 25 - 27