INTER- AND INTRAFRACTION VARIABILITY IN LIVER POSITION IN NON-BREATH-HOLD STEREOTACTIC BODY RADIOTHERAPY

被引:113
|
作者
Case, Robert B. [1 ]
Sonke, Jan-Jakob [2 ]
Moseley, Douglas J. [1 ]
Kim, John [1 ]
Brock, Kristy K. [1 ]
Dawson, Laura A. [1 ]
机构
[1] Univ Toronto, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
Image-guided radiotherapy; IGRT; Intrafraction reproducibility; kilovoltage cone-beam computed tomography; CBCT; CONE-BEAM CT; IMAGE-GUIDED RADIOTHERAPY; ACCELERATOR FOCAL UNIT; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; TUMOR POSITION; LUNG-CANCER; PHASE-I; LOCALIZATION; MOTION;
D O I
10.1016/j.ijrobp.2009.03.058
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for muresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility (sigma, n = 29 fractions) was 1.3 rum in the ML, 1.4 mm in the CC, and 1.6 rum in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction soft-tissue image guidance. The intrafraction change in liver position from the beginning to the end of each fraction was small for most patients. (c) 2009 Elsevier Inc.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Intrafraction reproducibility of liver position in patients undergoing cone beam CT image guided breath hold and free breathing stereotactic body radiotherapy
    Case, R. B.
    Moseley, D. J.
    Eccles, C.
    Kim, J.
    Dawson, L. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S270 - S270
  • [2] Intrafraction target shift comparison using two breath-hold systems in lung stereotactic body radiotherapy
    Prado, Alejandro
    Zucca, Daniel
    De la Casa, Miguel Angel
    Marti, Jaime
    Alonso, Leyre
    de Acilu, Paz Garcia
    Garcia, Juan
    Hernando, Ovidio
    Fernandez-Leton, Pedro
    Rubio, Carmen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 57 - 62
  • [3] Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy
    Turna, Menekse
    Kucukmorkoc, Esra
    Rzazade, Rashad
    Canoglu, Mehmet Dogu
    Kucuk, Nadir
    Caglar, Hale Basak
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2023, 28
  • [4] Impact on liver position under breath-hold by computed tomography contrast agents in stereotactic body radiotherapy of liver cancer
    Miura, Hideharu
    Ozawa, Shuichi
    Nakao, Minoru
    Doi, Yoshiko
    Kubo, Katsumaro
    Kenjo, Masahiro
    Nagata, Yasushi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (06) : 1035 - 1044
  • [5] Investigating Stability and Reproducibility of Deep Inspiration Breath Hold for Liver Stereotactic Body Radiotherapy
    Parsons, D.
    Iqbal, Z.
    Sanford, N. N.
    Reynolds, R.
    Stojadinovic, S.
    Aguilera, T. A.
    Chiu, T.
    Lu, W.
    Folkert, M. R.
    Gu, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E632 - E632
  • [6] Echo-train STIR MRI of the liver: Comparison of breath-hold and non-breath-hold imaging strategies
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01): : 87 - 92
  • [7] Intrafraction variation in tumor position during stereotactic body radiotherapy for lung cancer
    Hugo, G. D.
    Grills, I. S.
    Wloch, J.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S610 - S610
  • [8] Using kV Triggered Imaging and Liver Dome Position to Reduce the Dosimetric Error Caused by Breath Hold Variability for Liver Stereotactic Body Radiation Therapy
    Stephans, K. L.
    Woody, N. M.
    Xia, P.
    Guo, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S179 - S179
  • [9] Reproducibility of Target Position Using Moderate Voluntary Breath-Hold During Liver Stereotactic Ablative Radiotherapy
    Cui, G.
    Trakul, N.
    Chang, E.
    Shiu, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3612 - 3612
  • [10] Inter- and intrafraction imaging during stereotactic body radiation therapy: Which solutions for which tumours?
    Gensanne, D.
    Henni, A. Hadj
    Lauzin, Y.
    Clarisse, P.
    Thureau, S.
    CANCER RADIOTHERAPIE, 2019, 23 (08): : 891 - 895