Research on critical mode transferring characteristics for adjustable thermal vapor compressor in MED-TVC system

被引:0
|
作者
Yang, Yong [1 ,2 ]
Ren, Xiaotong [1 ,2 ]
Li, Yiqiao [1 ,2 ]
Zhou, Shihe [3 ]
Zhang, Kun [4 ]
Shen, Shengqiang [1 ,2 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Sch Energy & Power Engn, Dalian 116024, Liaoning, Peoples R China
[3] Dalian Univ Technol, Sch Ocean Sci & Technol, Panjin 124221, Liaoning, Peoples R China
[4] Dalian Ocean Univ, Sch Ocean & Civil Engn, Dalian 116023, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Desalination; Adjustable thermal vapor compressor; Critical mode; Transferring characteristics; Qualitative and quantitative combined regulation; MULTIPLE EFFECT EVAPORATION; FUEL-CELL SYSTEMS; EJECTOR REFRIGERATION; PERFORMANCE-CHARACTERISTICS; AREA-RATIO; MULTIEFFECT DISTILLATION; DESALINATION SYSTEM; WATER PRODUCTION; RANKINE-CYCLE; OPTIMIZATION;
D O I
10.5004/dwt.2022.28655
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present study, two special characteristics of "constant capacity" of thermal vapour compression (TVC) have been revealed and the advantage the adjustable TVC is researched based on the aerodynamic theory. And the spectrum features of critical mode transferring features under different condition of the adjustable TVC is obtained. The results indicate that the adjustable TVC can always operates on the optimal critical state based on combined regulation with varying primary pressure under different primary nozzle opening, which enlarges the range of stable operating condition of the TVC. In critical mode, the flow characteristics has strong similarity and the suction flow shows strong characteristics of "constant capacity". In the range of throat opening. from 80% to 120%, the adjustable TVC can promote the performance with entrainment ratio increasing 195.6% mean while the efficiency improving 148.7% in subcritical mode, and the entrainment ratio and efficiency improving 29.6% and 24.6%, respectively in critical mode.
引用
收藏
页码:13 / 26
页数:14
相关论文
共 14 条
  • [11] Performance analysis of mixed feed LT-MED desalination system with thermal vapor compressor
    Liu, Xiaohua
    Liu, Dawei
    Shen, Shengqiang
    Yang, Yong
    Gao, Feng
    DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) : 248 - 255
  • [12] A visual mass transfer study in the ejector considering phase change for multi-effect distillation with thermal vapour compression (MED-TVC) desalination system
    Ding, Hongbing
    Zhao, Yafei
    Wen, Chuang
    Wang, Chao
    Liu, Xixi
    DESALINATION, 2022, 532
  • [13] PERFORMANCE ANALYSIS AND THERMODYNAMIC MODELING OF A POLY GENERATION SYSTEM BY INTEGRATING A MULTI-EFFECT-DESALINATION THERMO-VAPOR COMPRESSION (MED-TVC) SYSTEM WITH A COMBINED COOLING, HEATING AND POWER (CCHP) SYSTEM
    Ghaebi, H.
    Abbaspour, G.
    JOURNAL OF THERMAL ENGINEERING, 2018, 4 (03): : 1963 - 1983
  • [14] Process simulation and techno-economic assessment of a zero liquid discharge/multi-effect desalination/thermal vapor compression (ZLD/MED/TVC) system
    Panagopoulos, Argyris
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (01) : 473 - 495