Development and characterization of an electrochemical biosensor for creatinine detection in human urine based on functional molecularly imprinted polymer

被引:73
|
作者
Diouf, A. [1 ,2 ]
Motia, S. [1 ,2 ]
El Hassani, N. El Alami [2 ]
El Bari, N. [2 ]
Bouchikhi, B. [1 ]
机构
[1] Moulay Ismail Univ, Sensor Elect & Instrumentat Grp, Dept Phys, Fac Sci, BP 11201, Zitoune, Meknes, Morocco
[2] Moulay Ismail Univ, Dept Biol, Biotechnol Agroalimentary & Biomed Anal Grp, Fac Sci, BP 11201, Zitoune 50003, Meknes, Morocco
关键词
Molecular imprinted polymer (MIP); Screen-printed gold electrodes; Creatinine; Biosensor; Human urine; SCIENCE-AND-TECHNOLOGY; SELECTIVE DETERMINATION; METHACRYLIC-ACID; RECOGNITION; SENSOR; PERFORMANCE; BILIRUBIN; BINDING; SHAPE;
D O I
10.1016/j.jelechem.2017.01.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, sensor based on a new molecularly imprinted polymer (MIP) for creatinine (Cre) detection, using screen-printed gold electrodes (Au-SPE), was developed. A carboxylic polyvinyl chloride (PVC-COOH) layer was first deposited on Au-SPE surface. The creatinine molecules were attached to the surface of Au-SPE/PVCCOOH. Afterward, the polymerization of acrylamide and N, N' methylenebisacrylamid filled vacant spaces around them. The subsequent templates removal left binding sites within the polymer which are capable of selectively recognizing creatinine at different concentrations. To test the sensitivity of this biosensor, the same procedure without creatinine was performed on a gold non-imprinted polymer (Au-SPE/NIP). Their retention and molecular-recognition properties were qualitatively investigated by means of three instrumental techniques: voltammetry (cyclic voltammetry (CV) and differential pulse voltammetry (DPV)), electrochemical impedance spectroscopy (EIS), and UV-Visible spectrophotometry (UV-Vis). The obtained results indicate that the MIP had a specific recognition ability for creatinine, while other structurally related compounds, such as urea or glucose, could not be recognized on the MIP. In addition, the biosensor was tested on volunteers with different creatinine urine levels and seemed a promising tool for screening creatinine in point-of-care. Moreover, Partial Least Square (PLS) analysis was used to obtain a correlation between the predicted creatinine concentrations from voltammetric measurements and concentrations measured by Jaffe's reaction as a reference method. The EIS and DPV biosensor responses show a limit of detection of 0.016 ng/mL and 0.081 ng/mL, respectively, with a linear range from 0.1 ng/mL to 1 mu g/mL. This study provides a promising strategy to fabricate sensor devices based on MIP with highly selective recognition ability, simplicity of operation, small size and low cost. Published by Elsevier B.V.
引用
收藏
页码:44 / 53
页数:10
相关论文
共 50 条
  • [41] Designing A Selective Electrochemical Nanosensor Based on Molecularly Imprinted Polymer for Detection of Pirfenidone
    Selcuk, Ozge
    Uslu, Bengi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (08)
  • [42] An Electrochemical Sensor Based on Molecularly Imprinted Polymer for Methyl Paraben Recognition and Detection
    Soysal, Mert
    Journal of Analytical Chemistry, 2021, 76 (03): : 381 - 389
  • [43] Development of a molecularly imprinted polymer-based electrochemical sensor for the selective detection of nerve agent VX metabolite ethyl methylphosphonic acid in human plasma and urine samples
    Sermet Sezigen
    S. Irem Kaya
    Nurgul K. Bakirhan
    Sibel A. Ozkan
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1505 - 1515
  • [44] Colorimetric test-systems for creatinine detection based on composite molecularly imprinted polymer membranes
    Sergeyeva, T. A.
    Gorbach, L. A.
    Piletska, E. V.
    Piletsky, S. A.
    Brovko, O. O.
    Honcharova, L. A.
    Lutsyk, O. D.
    Sergeeva, L. M.
    Zinchenko, O. A.
    El'skaya, A. V.
    ANALYTICA CHIMICA ACTA, 2013, 770 : 161 - 168
  • [45] An Electrochemical Molecularly Imprinted Polymer Sensor for Rapid β-Lactoglobulin Detection
    Wang, Bixuan
    Hong, Jingyi
    Liu, Chun
    Zhu, Liying
    Jiang, Ling
    SENSORS, 2021, 21 (24)
  • [46] Electrochemical sensor based on polydopamine-molecularly imprinted polymer for detection of 4-ethylphenyl sulfate "a novel gut metabolite": Fabrication, characterization, and performance evaluation in human urine
    Archana
    Verma, Damini
    Hashmi, S. Z. H.
    Lakshmi, G. B. V. S.
    Sajwan, Reena K.
    Kumar, Anil
    Solanki, Pratima R.
    MICROCHEMICAL JOURNAL, 2023, 193
  • [47] Synthesis and Characterization of a Polypyrrole-Based Molecularly Imprinted Polymer Electrochemical Sensor for the Selective Detection of Phosphate Ion
    Hikmat Hikmat
    Journal of Analytical Chemistry, 2023, 78 : 117 - 124
  • [48] A multifunctional molecularly imprinted polymer-based biosensor for direct detection of doxycycline in food samples
    Ashley, Jon
    Feng, XiaoTong
    Sun, Yi
    TALANTA, 2018, 182 : 49 - 54
  • [49] Synthesis and Characterization of a Polypyrrole-Based Molecularly Imprinted Polymer Electrochemical Sensor for the Selective Detection of Phosphate Ion
    Hikmat, Hikmat
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (01) : 117 - 124
  • [50] Molecularly Imprinted Polymers and Surface Imprinted Polymers Based Electrochemical Biosensor for Infectious Diseases
    Cui, Feiyun
    Zhou, Zhiru
    Zhou, H. Susan
    SENSORS, 2020, 20 (04)