Pathology of the bone-implant interfaces

被引:0
|
作者
Al-Saffar, N
Revell, PA
机构
[1] UCL Royal Free & Univ Coll, Sch Med, Dept Histopathol, London NW3 2PF, England
[2] UCL Royal Free & Univ Coll, Sch Med, Interdisciplinary Res Ctr Biomed Mat IRC, London NW3 2PF, England
关键词
arthroplasty; osteolysis; immune responses; infection; retrieval analysis;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Joint replacement surgery has a wide clinical application as a successful technique. However, the release of biomaterial in particulate form from various implant components has been implicated as a cause of two major clinical complications: 1)bone lysis with or without aseptic loosening, and 2) dissemination of wear particles to distant sites with adverse local or systemic cellular responses. This review focuses on the analysis of the clinical material obtained at the time of revision operations and its value in identifying the pathological processes taking place within the bone-implant microenvironment. Important issues discussed include the incidence of infection, characterization of wear particles, particle-cell interactions, local histopathological changes that lead to the formation of erosive inflammatory lesions next to the bone, sensitivity reactions, tumor formation, and the induction of inflammatory factors and cytokines that can influence the rate of bone resorption versus bone formation.
引用
收藏
页码:319 / 347
页数:29
相关论文
共 50 条
  • [21] The bone-implant interface: A dynamic surface
    Goldberg, VM
    Jinno, T
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1999, 9 (1-2) : 11 - 21
  • [22] Understanding and controlling the bone-implant interface
    Puleo, DA
    Nanci, A
    BIOMATERIALS, 1999, 20 (23-24) : 2311 - 2321
  • [23] Multiscale Analyses of the Bone-implant Interface
    Cha, J. Y.
    Pereira, M. D.
    Smith, A. A.
    Houschyar, K. S.
    Yin, X.
    Mouraret, S.
    Brunski, J. B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2015, 94 (03) : 482 - 490
  • [24] The bone-implant interface in regenerated bone and in host bone.
    Weng, D
    Hoffmeyer, M
    Hürzeler, MB
    Richter, EJ
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 510 - 510
  • [25] A Strain Distribution Sensing System for Bone-Implant Interfaces Based on Digital Speckle Pattern Interferometry
    Zhong, Ping
    Li, Zhisong
    Yang, Huazheng
    Tang, Xin
    He, Guoxing
    SENSORS, 2019, 19 (02)
  • [26] Biomechanical Effects of Various Bone-Implant Interfaces on the Stability of Orthodontic Miniscrews: A Finite Element Study
    Tan, Fabing
    Wang, Chao
    Yang, Chongshi
    Huang, Yuanding
    Fan, Yubo
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [27] INITIAL BONE-IMPLANT INTERFACES OF SUBMERGIBLE AND SUPRAMERGIBLE ENDOSSEOUS SINGLE-CRYSTAL SAPPHIRE IMPLANTS
    AKAGAWA, Y
    HASHIMOTO, M
    KONDO, N
    SATOMI, K
    TAKATA, T
    TSURU, H
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (01): : 96 - 100
  • [28] Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces
    Wazen, Rima M.
    Currey, Jennifer A.
    Guo, Hongqiang
    Brunski, John B.
    Helms, Jill A.
    Nanci, Antonio
    ACTA BIOMATERIALIA, 2013, 9 (05) : 6663 - 6674
  • [29] The effects of particulate bone cements at the bone-implant interface
    Wimhurst, JA
    Brooks, RA
    Rushton, N
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (04): : 588 - 592
  • [30] Use of Chitosan as a Bioactive Implant Coating for Bone-Implant Applications
    Leedy, Megan R.
    Martin, Holly J.
    Norowski, P. Andrew
    Jennings, J. Amber
    Haggard, Warren O.
    Bumgardner, Joel D.
    CHITOSAN FOR BIOMATERIALS II, 2011, 244 : 129 - 165