Volumetric modulated arc therapy with dynamic collimator rotation for improved multileaf collimator tracking of the prostate

被引:14
|
作者
Murtaza, Ghulam [1 ,2 ]
Toftegaard, Jakob [1 ]
Khan, Ehsan Ullah [2 ,3 ]
Poulsen, Per Rugaard [1 ]
机构
[1] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
[2] Int Islamic Univ, Dept Phys, Islamabad, Pakistan
[3] Muslim Youth Univ, Islamabad, Pakistan
关键词
IGRT; Prostate motion; MLC tracking; MOTION; RADIOTHERAPY; DELIVERY; KV;
D O I
10.1016/j.radonc.2016.11.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve MLC tracking of prostate VMAT plans by dynamic rotation of the collimator to align the MLC leaves with the dominant prostate motion direction. Methods: For 22 prostate cancer patients, two dual arc VMAT plans were made with (1) fixed collimators (45 and 315) and (2) a rotating collimator that aligned the MLC leaves with the dominant prostate motion direction (population-based first principal component). The fixed and rotating collimator plan quality was compared using selected dose-volume indices. Next, MLC tracking treatments were simulated with 695 patient-measured prostate traces. The MLC exposure error (under- and overexposed MLC area in beam's eye view) was calculated as a surrogate for the MLC tracking error. Finally, motion including dose reconstruction was performed for 35 motion traces for one patient, and the root-mean square dose error was compared with the MLC exposure error. Results: Rotating collimator VMAT plans were of similar quality as the fixed collimator plans, but significantly improved MLC tracking with 33% lower MLC exposure errors (p << 0.0001). The reductions in MLC exposure error correlated significantly with dose error reductions. Conclusion: Prostate VMAT plans with rotating collimator were of similar quality as fixed collimator plans, but more suitable for MLC tracking with significantly better agreement between planned and delivered dose distributions. MLC tracking for prostate cancer patients can therefore be improved without the requirement of additional efforts or hardware changes. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 50 条
  • [31] Collimator based tracking with an add-on multileaf collimator: Moduleaf
    Boehler, A.
    Weichenberger, H.
    Gaisberger, C.
    Sedlmayer, F.
    Deutschmann, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3257 - 3269
  • [32] Delivery of intensity-modulated treatments with dynamic multileaf collimator
    Boyer, AL
    Strait, JP
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 13 - 15
  • [33] Intensity-modulated radiation therapy using a multileaf collimator
    Webb, S
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 660 - 663
  • [34] Effect of Gantry and Collimator Positional Errors On Volumetric Modulated Arc Therapy(VMAT)
    Holla, R.
    Ravikumar, V. Anand
    Pillai, B.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [35] An electron specific multileaf collimator for modulated electron radiation therapy
    McNeeley, S
    Li, J
    Price, R
    Chen, L
    Ding, M
    Fourkal, E
    Ma, C
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1286 - 1286
  • [36] IMPLEMENTATION OF A NEW METHOD FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING OF PROSTATE MOTION IN ARC RADIOTHERAPY USING A SINGLE KV IMAGER
    Poulsen, Per Rugaard
    Cho, Byungchul
    Sawant, Amit
    Keall, Paul J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : 914 - 923
  • [37] The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy
    Okumura, M.
    Obata, Y.
    Shimomura, K.
    Tamura, M.
    Nishimura, Y.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11): : 3101 - 3113
  • [38] IMPACT OF COLLIMATOR LEAF WIDTH FOR INTENSITY MODULATED RADIOTHERAPY AND VOLUMETRIC INTENSITY MODULATED ARC THERAPY
    Krayenbuehl, J.
    Linsenmeier, C.
    Kloeck, S.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 518 - 518
  • [39] Determination of multileaf collimator positional errors as a function of dose rate, speed, and delivery interruption for volumetric-modulated arc therapy delivery
    Roy, Soumya
    Sarkar, Biplab
    Pradhan, Anirudh
    [J]. JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 286 - 294
  • [40] Evaluation of collimator rotation for volumetric modulated arc therapy lung stereotactic body radiation therapy using flattening filter free
    Sandrini, Emmily Santos
    da Silva, Ademir Xavier
    da Silva, Claudia Menezes
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 141 : 257 - 260