Energy Conservation Study on the Industrial Boiler and Steam Kettle System

被引:0
|
作者
Song, Jingdong [1 ]
Gan, Yunhua [2 ]
Li, Shihong [2 ]
机构
[1] Northeast Dianli Univ, Grad Dept, Jilin, Jilin, Peoples R China
[2] South China Univ Technol, Sch Elect Power, Guangzhou, Guangdong, Peoples R China
关键词
condensate water recovery; flash evaporation; steam jet compression;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to give some suggestions for energy conservation rebuilding, comparison analysis was carried out on the coal-fired industry boiler and steam kettle system. Three schemes of steam water reclaim from the steam kettle to the coalfired industrial boiler were put forward. The first scheme adopted a heat exchanger to reclaim the heat released from the condensate water and hot up the feed water of boiler. The second scheme adopted both the heat exchanger and flash evaporation to reclaim the heat released from the condensate water and hot up the feed water of boiler. And the third scheme adopted both flash evaporation and chemistry disposal technology to reclaim the condensate water and used as feed water of boiler. Based on comparison analysis, the first scheme was the simplest one and reclaimed the least heat, the third scheme was the most complex one and reclaimed the most heat. And the second scheme lied between the other two schemes. In a unit time, the three scheme can recover 417kW, 455kW and 521kW waste heat respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] OPTIMIZING THE CONTROL-SYSTEM OF A STEAM BOILER
    CZINDER, J
    [J]. PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 1978, 22 (04): : 255 - 263
  • [22] Control system simulator for steam boiler parameters
    Maican, Camelia
    Vinatoru, Matei
    Canureci, Gabriela
    Iangcu, Eugen
    [J]. WSEAS Transactions on Systems and Control, 2008, 3 (11): : 917 - 926
  • [23] Control System Simulator for Steam Boiler Parameters
    Maican, Camelia
    Vinatoru, Matei
    Canureci, Gabriela
    Iancu, Eugen
    [J]. NEW ASPECTS OF SYSTEMS, PTS I AND II, 2008, : 246 - +
  • [24] Saving energy lost from steam boiler vessels
    Abdallah, AM
    Ismail, AL
    [J]. RENEWABLE ENERGY, 2001, 23 (3-4) : 537 - 550
  • [25] BOILER BURNER RETROFIT SAVES ENERGY AND BOOSTS STEAM
    不详
    [J]. INSTRUMENTS & CONTROL SYSTEMS, 1980, 53 (12): : 65 - 65
  • [26] Dynamic System Modeling of Industrial Boiler
    Khalid, M. Adnan
    Kadri, Muhammad Bilal
    [J]. 17TH IEEE INTERNATIONAL MULTI TOPIC CONFERENCE 2014, 2014, : 354 - 359
  • [27] Study on robust control system of boiler steam temperature and analysis on its stability
    Han, Zhong-Xu
    Yan, Cui-Hui
    Zhang, Zhi
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (08): : 101 - 109
  • [28] INDUSTRIAL APPLICATION OF A DIRECT REFRIGERATION SYSTEM FOR ENERGY-CONSERVATION
    SHEA, DP
    SHELTON, JE
    WHITE, TL
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 170 - 173
  • [29] AN INDUSTRIAL STEAM PLANT - ECONOMICS ARISING FROM A SURVEY OF WATER STEAM PURITY AND BOILER EFFICIENCY
    KNIGHT, H
    FOSTER, J
    [J]. JOURNAL OF THE INSTITUTE OF FUEL, 1967, 40 (315): : 177 - &
  • [30] Operation optimization of electricity-steam coupled industrial energy system considering steam accumulator
    Zhuang, Wennan
    Zhou, Suyang
    Chen, Jinyi
    Gu, Wei
    [J]. ENERGY, 2024, 289