Evaluation of Four Similarity Measures for 2D/3D Registration in Image-Guided Intervention

被引:4
|
作者
Wang, Lei [1 ,2 ,3 ]
Gao, Xin [1 ]
Zhou, Zhiyong [1 ]
Wang, Xiaocong [4 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Jilin Univ, Hosp 1, Changchun 130021, Peoples R China
基金
中国国家自然科学基金;
关键词
2D/3D Rigid Registration; Similarity Measure; Mutual Information; Space Distance; Image-Guided Intervention; 3-D/2-D REGISTRATION; MUTUAL-INFORMATION; MEDICAL IMAGES; MAXIMIZATION; VALIDATION; CT;
D O I
10.1166/jmihi.2014.1274
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
2D/3D medical image registration in image-guided intervention is crucial to assist the clinician to establish the space corresponding relationship between image information and patients' anatomy, which can be quantified by a similarity measure. Among similarity measures, mutual information and its derivatives, were used widely for image registration, and showed significantly differences in the performances of registrations. However, the comparison of their registration performances has not been studied quantitatively yet. Therefore, in this paper, four similarity measures were evaluated for 2D/3D rigid registrations, which are mutual information (MI) and its three derivatives (distance coefficient mutual information (DCMI), distance weighted mutual information (DWMI), gradient weighted mutual information (GWMI)). They were applied to implement registrations based on porcine skull phantom datasets from the Medical University of Vienna, and were evaluated through the mean target registration errors (mTRE) for the registrations. The results demonstrated that the performance of DCMI was the most accurate and robust, and MI was the least effective of the four similarity measures. Moreover, due to the presence of a great amount of soft tissues, GWMI also had the low performance with its mean of mTRE even greater than that by MI, which suggested that intensity gradients were not always having a positive impact for 2D/3D rigid registration when involving a great amount of soft tissues. Between DCMI and DWMI, there were a significant difference in terms of accuracy and robustness, despite using the same image information for them, which means that the construction of an ideal measure should consider not only the image information to be involved but also the construction way of these information.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
  • [21] 3D nonrigid registration and multimodality fusion for image-guided neurosurgery
    Verly, JG
    Vigneron, LM
    Martin, C
    Petitjean, N
    Guran, R
    Robe, PA
    FUSION 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE OF INFORMATION FUSION, VOLS 1 AND 2, 2003, : 852 - 859
  • [22] Feasibility and Preliminary Validation of 2D/3D Image Registration Using Fixed 2-D X-Ray Devices in Image-Guided Radiotherapy
    Kremer, Florence
    Giard, Joachim
    Sibomana, Merence
    Seabra, Jose
    de Xivry, Jonathan Orban
    Labarbe, Rudi
    Macq, Benoit
    2014 1ST INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP 2014), 2014, : 172 - 176
  • [23] Similarity Registration Problems for 2D/3D Ultrasound Calibration
    Vasconcelos, Francisco
    Peebles, Donald
    Ourselin, Sebastien
    Stoyanov, Danail
    COMPUTER VISION - ECCV 2016, PT VI, 2016, 9910 : 171 - 187
  • [24] Evaluating similarity measure for multimodal 3D to 2D registration
    Kiran, Usha
    Naik, Roshan Ramakrishna
    Bhat, Shyamasunder N.
    Anitha, H.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (05)
  • [25] Retinal image registration from 2D to 3D
    Lin, Yuping
    Medioni, Gerard
    2008 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-12, 2008, : 2830 - 2837
  • [26] Advancements in 2D/3D Image Registration Methods
    Hjouj, Fawaz
    Jouini, Mohamed Soufiane
    Al-Khaleel, Mohammad
    IEEE ACCESS, 2023, 11 : 34698 - 34708
  • [27] 3D Surface Image-Guided
    Tang, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3816 - 3817
  • [28] A phantom study to evaluate three different registration platform of 3D/3D, 2D/3D, and 3D surface match with 6D alignment for precise image-guided radiotherapy
    Kuo, Hsiang-Chi
    Lovelock, Michael M.
    Li, Guang
    Ballangrud, Ase
    Wolthuis, Brian
    Della Biancia, Cesar
    Hunt, Margie A.
    Berry, Sean L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 188 - 196
  • [29] Deformable 3D/3D CT-to-digital-tomosynthesis image registration in image-guided bronchoscopy interventions
    Saad F.
    Frysch R.
    Saalfeld S.
    Kellnberger S.
    Schulz J.
    Fahrig R.
    Bhadra K.
    Nürnberger A.
    Rose G.
    Comput. Biol. Med., 2024,
  • [30] An Iterative Framework for Improving the Accuracy of Intraoperative Intensity-Based 2D/3D Registration for Image-Guided Orthopedic Surgery
    Otake, Yoshito
    Armand, Mehran
    Sadowsky, Ofri
    Armiger, Robert S.
    Kazanzides, Peter
    Taylor, Russell H.
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 23 - +