Evaluation of Four Similarity Measures for 2D/3D Registration in Image-Guided Intervention

被引:4
|
作者
Wang, Lei [1 ,2 ,3 ]
Gao, Xin [1 ]
Zhou, Zhiyong [1 ]
Wang, Xiaocong [4 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Jilin Univ, Hosp 1, Changchun 130021, Peoples R China
基金
中国国家自然科学基金;
关键词
2D/3D Rigid Registration; Similarity Measure; Mutual Information; Space Distance; Image-Guided Intervention; 3-D/2-D REGISTRATION; MUTUAL-INFORMATION; MEDICAL IMAGES; MAXIMIZATION; VALIDATION; CT;
D O I
10.1166/jmihi.2014.1274
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
2D/3D medical image registration in image-guided intervention is crucial to assist the clinician to establish the space corresponding relationship between image information and patients' anatomy, which can be quantified by a similarity measure. Among similarity measures, mutual information and its derivatives, were used widely for image registration, and showed significantly differences in the performances of registrations. However, the comparison of their registration performances has not been studied quantitatively yet. Therefore, in this paper, four similarity measures were evaluated for 2D/3D rigid registrations, which are mutual information (MI) and its three derivatives (distance coefficient mutual information (DCMI), distance weighted mutual information (DWMI), gradient weighted mutual information (GWMI)). They were applied to implement registrations based on porcine skull phantom datasets from the Medical University of Vienna, and were evaluated through the mean target registration errors (mTRE) for the registrations. The results demonstrated that the performance of DCMI was the most accurate and robust, and MI was the least effective of the four similarity measures. Moreover, due to the presence of a great amount of soft tissues, GWMI also had the low performance with its mean of mTRE even greater than that by MI, which suggested that intensity gradients were not always having a positive impact for 2D/3D rigid registration when involving a great amount of soft tissues. Between DCMI and DWMI, there were a significant difference in terms of accuracy and robustness, despite using the same image information for them, which means that the construction of an ideal measure should consider not only the image information to be involved but also the construction way of these information.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
  • [1] Evaluation of similarity measures for 3D/2D image registration
    Skerl, Darko
    Likar, Bostjan
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [2] Evaluation of similarity measures and optimization methods for 2D/3D rigid registration in image guided interventions
    Zhang, Ran
    Wang, Lei
    Xia, Wei
    Gao, Xin
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCES AND APPLICATIONS (CSA), 2013, : 623 - 626
  • [3] A review of 3D/2D registration methods for image-guided interventions
    Markelj, P.
    Tomazvic, D.
    Likar, B.
    Pernus, F.
    [J]. MEDICAL IMAGE ANALYSIS, 2012, 16 (03) : 642 - 661
  • [4] Multi-step 3D/2D image registration for image-guided spinal surgery
    Zhang, Yi
    Wang, Manning
    Song, Zhijian
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 188 - +
  • [5] A Novel Mutual Information-based Similarity Measure for 2D/3D Registration in Image Guided Intervention
    Wang, Lei
    Gao, Xin
    Fang, Qiang
    [J]. 1ST INTERNATIONAL CONFERENCE ON ORANGE TECHNOLOGIES (ICOT 2013), 2013, : 135 - 138
  • [6] Multi-step 2D/3D image registration in image-guided spine surgery
    Digital Medical Research Center, Fudan University, Shanghai 200032, China
    [J]. Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao, 2007, 9 (1154-1158+1165): : 1154 - 1158
  • [7] 3D–2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms
    Uroš Mitrović
    Boštjan Likar
    Franjo Pernuš
    Žiga Špiclin
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 193 - 202
  • [8] Evaluation of similarity measures for 3D- 2D image registration based on matching structure tensors
    Spiclin, Ziga
    [J]. ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2015, 82 (1-2): : 66 - 72
  • [9] Analysis of 2D/3D image data for 3D visualization during image-guided interventions
    Department of Neurosurgery, Toshiba Stroke Research Center, State University of New York at Buffalo, 3435 Main Street, Buffalo, NY 14214
    [J]. Inf Disp, 2006, 7 (10-15):
  • [10] A Comparison of Two Novel Similarity Measures Based on Mutual Information in 2D/3D Image Registration
    Wang, Lei
    Gao, Xin
    Zhang, Ran
    Xia, Wei
    [J]. PROCEEDINGS OF 2013 IEEE INTERNATIONAL CONFERENCE ON MEDICAL IMAGING PHYSICS AND ENGINEERING (ICMIPE), 2013, : 215 - 218