High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?

被引:1
|
作者
Sousa, Pedro A. [1 ]
Puga, Luis [1 ]
Barra, Sergio [2 ]
Campos, Diana [1 ]
Antonio, Natalia [1 ,3 ]
Elvas, Luis [1 ]
Goncalves, Lino [1 ,3 ]
机构
[1] Coimbras Hosp & Univ Ctr, Cardiol Dept, Pacing & Electrophysiol Unit, Morada Praceta Prof Mota Pinto, P-3000075 Coimbra, Portugal
[2] Hosp Luz Arrabida, Cardiol Dept, Vn Gaia, Portugal
[3] Univ Coimbra, Fac Med, ICBR, Coimbra, Portugal
关键词
Ablation Index; High-Sensitivity Cardiac Troponin I; Ablation Effectiveness Quotient; Pulmonary Vein Isolation; Atrial Fibrillation; Arrhythmia Recurrence; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; RECONNECTION;
D O I
10.1007/s10840-022-01229-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. Methods Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. Results Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. Conclusions The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 45 条
  • [21] Greater distance between ablation lines reduces the arrhythmia recurrence rate after pulmonary vein isolation
    Peller, Michal
    Wawrzenczyk, Mateusz
    Ciecierski, Piotr
    Balsam, Pawel
    Marchel, Michal
    Krzowski, Bartosz
    Maciejewski, Cezary
    Mitrzak, Karolina
    Grabowski, Marcin
    Opolski, Grzegorz
    Lodzinski, Piotr
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2024, 134 (04):
  • [22] Effectiveness of first-pass pulmonary vein isolation with index-guided ablation compared to very-high-power, short-duration ablation: A retrospective single-center study
    Peller, Michal
    Dzwinacka, Julia
    Krzowski, Bartosz
    Marchel, Michal
    Maciejewski, Cezary
    Mitrzak, Karolina
    Opolski, Grzegorz
    Grabowski, Marcin
    Balsam, Pawel
    Lodzinski, Piotr
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2025, 83 (01): : 35 - 42
  • [23] Lower contact force predicts right pulmonary vein carina breakthrough after ablation index-guided pulmonary vein isolation using high-power short-duration
    Chen, Wei-Tso
    Chung, Fa-Po
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Lin, Chin-Yu
    Chang, Ting-Yung
    Kuo, Ling
    Wu, Cheng-, I
    Liu, Chih-Min
    Liu, Shin-Huei
    Hsieh, Yu-Cheng
    Li, Cheng-Hung
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (01) : 60 - 68
  • [24] Association between left atrial wall thickness and residual potential after pulmonary vein antral isolation in patients with atrial fibrillation receiving Ablation Index-guided ablation
    Lee, S. R.
    Lee, E. J.
    Cha, M. J.
    Choi, E. K.
    Oh, S.
    EUROPEAN HEART JOURNAL, 2020, 41 : 607 - 607
  • [25] Two years after pulmonary vein isolation guided by ablation index-a multicenter study
    Sousa, Pedro A.
    Puga, Luis
    Adao, Luis
    Primo, Joao
    Khoueiry, Ziad
    Lebreiro, Ana
    Fonseca, Paulo
    Lagrange, Philippe
    Elvas, Luis
    Goncalves, Lino
    JOURNAL OF ARRHYTHMIA, 2022, 38 (03) : 346 - 352
  • [26] Impact of local left atrial wall thickness on the incidence of acute pulmonary vein reconnection after Ablation Index-guided atrial fibrillation ablation
    Mulder, Mark J.
    Kemme, Michiel J. B.
    Hagen, Amaya M. D.
    Hopman, Luuk H. G. A.
    van de Ven, Peter M.
    Hauer, Herbert A.
    Tahapary, Giovanni J. M.
    Gotte, Marco J. W.
    van Rossum, Albert C.
    Allaart, Cornelis P.
    IJC HEART & VASCULATURE, 2020, 29
  • [27] High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation
    Okamatsu, Hideharu
    Koyama, Junjiro
    Sakai, Yoshirou
    Negishi, Koudai
    Hayashi, Katsuhide
    Tsurugi, Takuo
    Tanaka, Yasuaki
    Nakao, Koichi
    Sakamoto, Tomohiro
    Okumura, Ken
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2751 - 2758
  • [28] High-sensitivity cardiac Troponin T delta concentration after repeat pulmonary vein isolation
    Zeljkovic, Ivan
    Knecht, Sven
    Spies, Florian
    Reichlin, Tobias
    Schaer, Beat
    Osswald, Stefan
    Kuhne, Michael
    Sticherling, Christian
    BIOCHEMIA MEDICA, 2019, 29 (02)
  • [29] Ablation index-guided pulmonary vein isolation can reduce early recurrences of atrial tachyarrhythmias: a propensity score-matched analysis
    Yasumoto, Koji
    Egami, Yasuyuki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Tsuda, Masaki
    Okamoto, Naotaka
    Tanaka, Akihiro
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Shutta, Ryu
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) : 479 - 487
  • [30] Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
    Chen, Shaojie
    Schmidt, Boris
    Bordignon, Stefano
    Urbanek, Lukas
    Tohoku, Shota
    Bologna, Fabrizio
    Angelkov, Lazar
    Garvanski, Iskren
    Tsianakas, Nikolaos
    Konstantinou, Athanasios
    Trolese, Luca
    Weise, Felix
    Perrotta, Laura
    Chun, K. R. Julian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2724 - 2731