Design and fabrication of a passive upper limb rehabilitation robot with adjustable automatic balance based on variable mass of end-effector

被引:7
|
作者
Eslami, Majid [1 ]
Mokhtarian, Ali [1 ]
Pirmoradian, Mostafa [1 ]
Seifzadeh, Alireza [2 ]
Rafiaei, Masoud [3 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, Khomeinishahr Branch, Esfahan, Iran
[2] Islamic Azad Univ, Dept Biomed Engn, Khomeinishahr Branch, Esfahan, Iran
[3] Isfahan Univ Med Sci, Sch Rehabil, Esfahan, Iran
关键词
Passive robot; Automatic balance; End-effector’ s variable mass; Control panel; Rehabilitation robotics; STIMULATION; EXOSKELETON; ORTHOSIS;
D O I
10.1007/s40430-020-02707-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The purpose of this work is to design and fabricate a balanced passive robotic arm with the capability of applying variable mass to the end-effector in order to upper limb rehabilitation. To achieve this purpose, the first step is associated with establishing a robot structural design in the CAD environment. The next step is focused on developing the kinematic model based on the degrees of freedom and joint range of motion of the lower legs. Thereafter, the potential energy functions are determined for the springs and weight of components applied in the mechanism. The genetic algorithm is employed as a proper optimization program to extract the system design parameters, including the spring stiffness coefficients and their placement positions within the system. A prototype is fabricated for a balanced robot, and the end-effector mass variations are utilized to develop an adjustable balance capability. To create balance in the system, several items are designed, consisting of a control panel, two electric motors, and an electronic processor. This situation provides an equivalent force equal to the weight of selected mass from the end-effector to the user's hand. (It is done by a reverse process.) The actual mass required for robot balance is compared to the mass defined in the simulation environment. The evaluation results indicate that it is possible to create an optimized balance by using the simulation outputs.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Robotic rehabilitation for end-effector device and botulinum toxin in upper limb rehabilitation in chronic post-stroke patients: an integrated rehabilitative approach
    Teresa Paolucci
    Francesco Agostini
    Massimiliano Mangone
    Andrea Bernetti
    Letizia Pezzi
    Vitalma Liotti
    Elena Recubini
    Cristina Cantarella
    Rosa Grazia Bellomo
    Carlo D’Aurizio
    Raoul Saggini
    [J]. Neurological Sciences, 2021, 42 : 5219 - 5229
  • [32] Design and Characterization of a Self-Aligning End-Effector Robot for Single-Joint Arm Movement Rehabilitation
    Jeyabalan, Prem Kumar Mathavan
    Nehrujee, Aravind
    Elias, Samuel
    Kumar, M. Magesh
    Sujatha, S.
    Balasubramanian, Sivakumar
    [J]. ROBOTICS, 2023, 12 (06)
  • [33] Robotic rehabilitation for end-effector device and botulinum toxin in upper limb rehabilitation in chronic post-stroke patients: an integrated rehabilitative approach
    Paolucci, Teresa
    Agostini, Francesco
    Mangone, Massimiliano
    Bernetti, Andrea
    Pezzi, Letizia
    Liotti, Vitalma
    Recubini, Elena
    Cantarella, Cristina
    Bellomo, Rosa Grazia
    D'Aurizio, Carlo
    Saggini, Raoul
    [J]. NEUROLOGICAL SCIENCES, 2021, 42 (12) : 5219 - 5229
  • [34] Design of a new passive end-effector based on constant-force mechanism for robotic polishing
    Wei, Yuzhang
    Xu, Qingsong
    [J]. ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2022, 74
  • [35] Design of automatic picking up seedling end-effector based on mechanical properties of plug seedlings
    Han, Lühua
    Mao, Hanping
    Miao, Xiaohua
    Hu, Jianping
    Yang, Xuejun
    [J]. Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2013, 44 (11): : 260 - 265
  • [36] KINEMATIC ANALYSIS OF THE VARIABLE HEIGHT ROTATING MECHANISM FOR END-TRACTION UPPER LIMB REHABILITATION ROBOT
    Liang, Dongtai
    Feng, Yongfei
    Yang, Shengye
    Tang, Min
    Wu, Liangda
    Jin, Di
    Vladareanu, Luige
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2023, 38 (02): : 85 - 96
  • [37] Mechanical design and Optimization on a Home-based Upper Limb Rehabilitation Robot
    Li, Lutong
    Tyson, Sarah
    Preston, Nick
    Weightman, Andrew
    [J]. PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 1057 - 1062
  • [38] An Estimation Method of Antagonistic Ratios of Functional Effective Muscles of Upper Limb Based on Maximum Force Distribution at End-Effector
    Tojo, Naoya
    Shimono, Tomoyuki
    [J]. IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 5242 - 5247
  • [39] Variable Robot- Resistance Rehabilitation for Upper Limb Based on an sEMG-Driven Model
    Huang, Shuangyuan
    Cai, Siqi
    Li, Guofeng
    Chen, Yan
    Xie, Longhan
    [J]. 2019 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2019, : 814 - 818
  • [40] Design and Implementation of BCI-based Intelligent Upper Limb Rehabilitation Robot System
    Kim, Tae-Yeun
    Kim, Sung-Hwan
    Ko, Hoon
    [J]. ACM TRANSACTIONS ON INTERNET TECHNOLOGY, 2021, 21 (03)