A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque

被引:4
|
作者
Lv, Peng [1 ,2 ]
Dai, Yuanyuan [1 ,2 ]
Lin, Jiang [1 ,2 ]
Zhang, Weisheng [3 ]
Liu, Hao [1 ,2 ]
Liu, Hui [1 ,2 ]
Tang, Xiao [4 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Radiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Med Imaging, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, 222 Zhongshan Rd, Dalian 116011, Peoples R China
[4] Fudan Univ, Zhongshan Hosp, Dept Vasc Surg, Shanghai, Peoples R China
来源
关键词
Carotid artery; Plaque; Atherosclerosis; Magnetic resonance imaging; HIGH-RESOLUTION MRI; INITIAL-EXPERIENCE; SINGLE-SLAB; FIBROUS CAP; ANGIOGRAPHY; COMPONENTS; STENOSIS; ARTERY; REPRODUCIBILITY; HEMORRHAGE;
D O I
10.1007/s10554-016-1017-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74-3.04 (2.44), 0.98-1.66 (1.39), and 1.91-2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97-3.41 (2.44), 1.18-1.73 (1.43), and 2.26-3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.
引用
收藏
页码:395 / 400
页数:6
相关论文
共 50 条
  • [41] Isotropic 3-D T2-weighted spin-echo for abdominal and pelvic MRI in children
    Dias, Silvia Costa
    Olsen, Oystein E.
    [J]. PEDIATRIC RADIOLOGY, 2012, 42 (11) : 1385 - 1390
  • [42] Isotropic 3-D T2-weighted spin-echo for abdominal and pelvic MRI in children
    Sílvia Costa Dias
    Øystein E. Olsen
    [J]. Pediatric Radiology, 2012, 42 : 1385 - 1390
  • [43] Clinical applications of 3D T2-weighted MRI in pelvic imaging
    Lim, Kelvin K.
    Noe, Geertje
    Hornsey, Emma
    Lim, Ruth P.
    [J]. ABDOMINAL IMAGING, 2014, 39 (05): : 1052 - 1062
  • [44] Clinical applications of 3D T2-weighted MRI in pelvic imaging
    Kelvin K. Lim
    Geertje Noe
    Emma Hornsey
    Ruth P. Lim
    [J]. Abdominal Imaging, 2014, 39 : 1052 - 1062
  • [45] Preliminary Clinical Experience at 3 T With a 3D T2-Weighted Sequence Compared With Multiplanar 2D for Evaluation of the Female Pelvis
    Hecht, Elizabeth M.
    Yitta, Silaja
    Lim, Ruth P.
    Fitzgerald, Erin F.
    Storey, Pippa
    Babb, James S.
    Bani-baker, Kamil O.
    Bennett, Genevieve L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W346 - W352
  • [46] MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time
    Rodrigo de Castro Luna
    Neil M. Kumar
    Jan Fritz
    Shivani Ahlawat
    Laura M. Fayad
    [J]. European Radiology, 2022, 32 : 8670 - 8680
  • [47] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [48] Synthetic T2-weighted images of the lumbar spine derived from an accelerated T2 mapping sequence: Comparison to conventional T2w turbo spin echo
    Raudner, Marcus
    Toth, Daniel F.
    Schreiner, Markus M.
    Hilbert, Tom
    Kober, Tobias
    Juras, Vladimir
    Windhager, Reinhard
    Trattnig, Siegfried
    [J]. MAGNETIC RESONANCE IMAGING, 2021, 84 : 92 - 100
  • [49] T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms
    Rubinstein, D
    Sandberg, EJ
    Breeze, RE
    Sheppard, SK
    Perkins, TG
    CajadeLaw, AG
    Simon, JH
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (10) : 1939 - 1943
  • [50] MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time
    de Castro Luna, Rodrigo
    Kumar, Neil M.
    Fritz, Jan
    Ahlawat, Shivani
    Fayad, Laura M.
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (12) : 8670 - 8680