A new measurement technique to determine the Amplitude and Phase shift of a sinusoidal voltage signal using a charge balanced digitizer

被引:0
|
作者
Bandi, A. Sai Kartheek [1 ]
Vooka, Prashanth [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Tirupati, Andhra Pradesh, India
关键词
Phase angle measurement; Amplitude measurement; Digitizer; Charge balance based digitizer;
D O I
10.1109/I2MTC48687.2022.9806619
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, a digitizer that uses a new measurement technique to determine the unknown parameters of a sinusoidal voltage signal is proposed. The technique is based on the charge balance principle. The amplitude and phase shift of the unknown sinusoidal signal are calculated based on the number of transitions that occur due to continuous charging and discharging of a capacitor. A laboratory prototype is designed and tested for different amplitudes and angles of all the quadrants. Results indicate an accuracy of 50 mV in amplitude and 0.50 in phase with a 11-bit resolution.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] New Method for Sinusoidal Signal Phase Measurement
    Zou Liyan
    Wang Qi
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOL. 3, 2008, : 1267 - 1270
  • [2] Amplitude and phase measurement of sinusoidal vibration in the nanometer range using laser interferometry
    Physikalisch-Technische, Bundesanstalt, Berlin, Germany
    Meas J Int Meas Confed, 1 (55-67):
  • [3] In-Phase and Quadrature-Phase Sinusoidal Signal Generation Using DDS Technique
    D'Souza, Alfred Vivek
    Ravi, D. J.
    IETE JOURNAL OF RESEARCH, 2023, 69 (07) : 4273 - 4280
  • [4] Measurement of % water concentration using microwave signal phase shift
    Ferrin, C
    ISA 2002 TECHNOLOGY UPDATE, VOL LVII, PT 1, 2002, 422 : 45 - 55
  • [5] HETERODYNE TECHNIQUE FOR THE DIRECT MEASUREMENT OF THE AMPLITUDE AND PHASE OF PHOTOREFRACTIVE SPACE-CHARGE FIELDS
    GRAY, DG
    MOHARAM, MG
    AYRES, TM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1994, 11 (03) : 470 - 475
  • [6] Space charge measurement using pulsed electroacoustic technique and signal recovery
    Vázquez, A
    Chen, G
    Davies, AE
    Bosch, R
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 1999, 19 (6-7) : 1219 - 1222
  • [7] A New Definition of Voltage Unbalance Using Supply Phase Shift
    Adekitan, Aderibigbe Israel
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2020, 31 (03) : 718 - 725
  • [8] A New Definition of Voltage Unbalance Using Supply Phase Shift
    Aderibigbe Israel Adekitan
    Journal of Control, Automation and Electrical Systems, 2020, 31 : 718 - 725
  • [9] Three-phase grid voltage synchronization using sinusoidal amplitude integrator in synchronous reference frame
    Du, Xiong
    Liu, Yandong
    Wang, Guoning
    Sun, Pengju
    Tai, Heng-Ming
    Zhou, Luowei
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 861 - 872
  • [10] Amplitude and phase estimations in the shortened measurement time using average values of signal
    Agrez, Dusan
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1230 - 1235