Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis

被引:20
|
作者
Baharuddin, Mohd Yusof [1 ,2 ]
Salleh, Sh-Hussain [2 ]
Zulkifly, Ahmad Hafiz [3 ]
Lee, Muhammad Hisyam [4 ]
Noor, Alias Mohd [2 ]
Harris, Arief Ruhullah A. [2 ]
Majid, Norazman Abdul [2 ]
Abd Kader, Ab Saman [5 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur, Malaysia
[2] Univ Teknol Malaysia, Ctr Biomed Engn, Transportat Res Alliance, Skudai, Johor, Malaysia
[3] Int Islamic Univ Malaysia, Kuliyyah Med, Dept Orthopaed Traumatol & Rehabil, Kuantan, Pahang, Malaysia
[4] Univ Teknol Malaysia, Fac Sci, Dept Math Sci, Skudai, Johor, Malaysia
[5] Univ Teknol Malaysia, Transportat Res Alliance, Skudai, Johor, Malaysia
来源
关键词
Morphology; Femur; Hip replacement; Cementless hip; Finite element analysis; TOTAL HIP-ARTHROPLASTY; FOLLOW-UP EVALUATION; PROXIMAL FEMUR; PRIMARY STABILITY; IMPLANT MICROMOTION; BONE-RESORPTION; ANATOMIC BASIS; REVISION HIP; CUSTOM-MADE; PROSTHESIS;
D O I
10.1186/1471-2474-15-30
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods. Methods: This complete design cycle began with morphological analysis, followed by femoral stem design, fit and fill analysis, and nonlinear finite element analysis (FEA). Various femur parameters for periosteal and endosteal canal diameters are measured from the osteotomy level to 150 mm below to determine the isthmus position. Results: The results showed better total fit (53.7%) and fill (76.7%) canal, with more load distributed proximally to prevent stress shielding at calcar region. The stem demonstrated lower displacement and micromotion (less than 40 mu m) promoting osseointegration between the stem-bone and providing primary fixation stability. Conclusion: This new design process could be used as a preclinical assessment tool and will shorten the design cycle by identifying the major steps which must be taken while designing the femoral stem.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
    Mohd Yusof Baharuddin
    Sh-Hussain Salleh
    Ahmad Hafiz Zulkifly
    Muhammad Hisyam Lee
    Alias Mohd Noor
    Arief Ruhullah A Harris
    Norazman Abdul Majid
    Ab Saman Abd Kader
    [J]. BMC Musculoskeletal Disorders, 15
  • [2] Design optimization of cementless femoral hip prostheses using finite element analysis
    Kowalczyk, P
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05): : 396 - 402
  • [3] Finite Element Analysis on the Hollow Porous Design at the Proximal End of Cementless Femoral Prosthesis Stem
    He, S.
    Zhu, J.
    Zhao, J.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (09) : 1276 - 1280
  • [4] Subject specific finite element analysis of implant stability for a cementless femoral stem
    Pettersen, Sune H.
    Wik, Tina S.
    Skallerud, Bjorn
    [J]. CLINICAL BIOMECHANICS, 2009, 24 (06) : 480 - 487
  • [5] Finite Element Analysis of Optimal Design of Distal Geometry of Cementless Femoral Prosthesis
    Zhao, Y.
    Wang, L.
    Bao, Y.
    Xu, R.
    He, S.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (09) : 1476 - 1483
  • [6] Nonlinear three-dimensional finite element analysis of newly designed cementless total hip stems
    Ando, M
    Imura, S
    Omori, H
    Okumura, Y
    Bo, A
    Baba, H
    [J]. ARTIFICIAL ORGANS, 1999, 23 (04) : 339 - 346
  • [7] Subject specific finite element analysis of stress shielding around a cementless femoral stem
    Pettersen, Sune H.
    Wik, Tina S.
    Skallerud, Bjorn
    [J]. CLINICAL BIOMECHANICS, 2009, 24 (02) : 196 - 202
  • [8] Cementless implant composition and femoral stress - A finite element analysis
    Namba, RS
    Keyak, JH
    Kim, AS
    Vu, LP
    Skinner, HB
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (347) : 261 - 267
  • [9] Design and finite element analysis of femoral stem prosthesis using functional graded materials
    Ahirwar, Harbhajan
    Sahu, Ankit
    Gupta, Vijay Kumar
    Kumar, Prasoon
    Nanda, Himansu Sekhar
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (11) : 1262 - 1275
  • [10] Three-dimensional finite element analysis of femoral neck stress
    Kramer, Patricia Ann.
    Sylvester, Adam D.
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2016, 159 : 196 - 196