Finite Element Analysis of Optimal Design of Distal Geometry of Cementless Femoral Prosthesis

被引:1
|
作者
Zhao, Y. [1 ]
Wang, L. [1 ]
Bao, Y. [2 ]
Xu, R. [2 ]
He, S. [1 ]
机构
[1] Nanjing Med Univ Suzhou, Affiliated Suzhou Sci & Technol Town Hosp, Dept Orthopaed, Suzhou, Jiangsu, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Dept Aerosp Mfg Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Cross groove; distal femoral prosthesis; finite element analysis; taper hole; total hip replacement; TOTAL HIP-ARTHROPLASTY; BETA-TYPE TI-33.6NB-4SN; STEM;
D O I
10.4103/njcp.njcp_1888_21
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim and Background: This study aims to improve the geometric design of the distal cementless femoral prosthesis stem, thereby changing the stress distribution of the femoral prosthesis and reducing the proximal stress shielding and distal stress concentration of the femur, so as to obtain better bone growth and long-term stability. Materials and Methods: Two geometric shapes of the femoral stems, namely, inverted hollow cone and cross-shaped bottom groove, are designed for the distal femoral prosthesis. The model is built based on the femoral computed tomography (CT) data of healthy volunteers, and the finite element method is used to analyze and calculate the stress distribution of the two femoral prosthesis stems. Results: According to the length and width of bottom "cross" groove, the stress values of the femoral region of the cross-grooved distal femur are divided into five groups, namely, group 1 (length 1:1, groove width 1.0 mm); group 2 (length 1:1, groove width 1.5 mm); group 3 (length 1:1, groove width 2.0 mm); group 4 (length 1:2, groove width 1.0 mm); group 5 (length 1:2, groove 1.5 mm wide). And the non-grooved group of the distal femur is designated as group 0. In the segment A, B, and C of the femoral region, the difference in the mean stress between group 0 and groups 1, 2, and 3 have statistical significance. Conclusion: The bottom "cross" groove of the distal femoral prosthesis can change the stress distribution in the prosthesis-distal femoral region and reduce the stress concentration at the distal prosthesis. Wherein, the grooved design of length ratio 1:1 is more advantageous.
引用
收藏
页码:1476 / 1483
页数:8
相关论文
共 50 条
  • [1] Finite Element Analysis on the Hollow Porous Design at the Proximal End of Cementless Femoral Prosthesis Stem
    He, S.
    Zhu, J.
    Zhao, J.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (09) : 1276 - 1280
  • [2] Design optimization of cementless femoral hip prostheses using finite element analysis
    Kowalczyk, P
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05): : 396 - 402
  • [3] Cementless implant composition and femoral stress - A finite element analysis
    Namba, RS
    Keyak, JH
    Kim, AS
    Vu, LP
    Skinner, HB
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (347) : 261 - 267
  • [4] Finite element analysis of new stemless femoral prosthesis
    Wang Chao
    Gong Xiansheng
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MECHANICAL TRANSMISSIONS, VOLS 1 AND 2, 2006, : 1641 - 1645
  • [5] Finite Element Analysis of Thermal Stress for Femoral Prosthesis
    Wang, Monan
    [J]. ADVANCED ENGINEERING MATERIALS III, PTS 1-3, 2013, 750-752 : 2212 - 2215
  • [6] Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
    Baharuddin, Mohd Yusof
    Salleh, Sh-Hussain
    Zulkifly, Ahmad Hafiz
    Lee, Muhammad Hisyam
    Noor, Alias Mohd
    Harris, Arief Ruhullah A.
    Majid, Norazman Abdul
    Abd Kader, Ab Saman
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [7] Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
    Mohd Yusof Baharuddin
    Sh-Hussain Salleh
    Ahmad Hafiz Zulkifly
    Muhammad Hisyam Lee
    Alias Mohd Noor
    Arief Ruhullah A Harris
    Norazman Abdul Majid
    Ab Saman Abd Kader
    [J]. BMC Musculoskeletal Disorders, 15
  • [8] Design and finite element analysis of femoral stem prosthesis using functional graded materials
    Ahirwar, Harbhajan
    Sahu, Ankit
    Gupta, Vijay Kumar
    Kumar, Prasoon
    Nanda, Himansu Sekhar
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (11) : 1262 - 1275
  • [9] The design of a knee prosthesis by Finite Element Analysis
    Iniguez-Macedo, Saul
    Somovilla-Gomez, Fatima
    Lostado-Lorza, Ruben
    Corral-Bobadilla, Marina
    Angeles Martinez-Calvol, Maria
    Sanz-Adan, Felix
    [J]. ADVANCES ON MECHANICS, DESIGN ENGINEERING AND MANUFACTURING, 2017, : 446 - 454
  • [10] Finite element analysis of intraosseous distal radioulnar joint prosthesis
    Farzaneh Gholamian
    Mehran Ashrafi
    Ali Moradi
    [J]. BMC Musculoskeletal Disorders, 23