Effect of culture temperature on high-voltage pulse sterilization of Escherichia coli

被引:62
|
作者
Ohshima, T [1 ]
Okuyama, K [1 ]
Sato, M [1 ]
机构
[1] Gunma Univ, Fac Engn, Dept Biol & Chem Engn, Kiryu, Gumma 3768515, Japan
关键词
PEF sterilization; Escherichia coli; cultivation temperature; cell membrane structure; high-voltage pulse; Arrhenius plot;
D O I
10.1016/S0304-3886(01)00206-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effect of culture temperature of Escherichia coli on pulsed electric field (PEF) sterilization has been studied. PEF sterilization, which is a method of inactivation of cells by a high-voltage pulsed electric field, was used. The E. coli cells cultivated at 20degreesC,(:) 30degreesC, 37degreesC, and 42degreesC, respectively, were collected and homogenous PEF of 16kV/cm. and 50Hz was applied at various temperatures. When the E. coli cells were cultivated at 20degreesC or 42degreesC, the cells were more easily sterilized by PEF sterilization than the E. coli cells cultivated at 37degreesC, which is the optimal culture temperature of E. coli. The survival ratio after a dose of 100 J/ml of PEF at 50degreesC was about 10(-2) and 10(-3) as the E. coli cells were cultivated at 30degreesC or 37degreesC and 20degreesC or 42degreesC, respectively. These results indicate that the sterilization efficiency is dependent on the culture temperature even if the same bacteria are used. The death rates of the E coli cells under various conditions were shown in a form of an Arrhenius plot. It was revealed that the efficiency of PEF sterilization is influenced by the PEF treatment temperature and this dependence changes between 30degreesC and 40degreesC of PEF treatment temperature. Moreover, the death rate of bacteria was found to be considerably influenced by the culture temperature of the E. coli cells. The E. coli cells cultivated at 37degreesC were practically resistant against PEF sterilization, while the cells cultivated at 20degreesC or 42degreesC were easily killed. Our results suggested that it is important to check the culture temperature of treated bacteria if PEF sterilization is applied in the industry. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 50 条
  • [41] High-temperature, high-voltage operation of pulse-doped diamond MESFET
    Vescan, A
    Gluche, P
    Ebert, W
    Kohn, E
    IEEE ELECTRON DEVICE LETTERS, 1997, 18 (05) : 222 - 224
  • [42] HIGH-TEMPERATURE PROCESSES IN POWDER MATERIALS AT HIGH-VOLTAGE ELECTRIC PULSE CONSOLIDATION
    Grigoryev, E.
    Kuznechik, O.
    Chumakov, A.
    Nikonchuk, I.
    Strizhakov, E.
    Nescoromniy, S.
    Ageev, S.
    HIGH TEMPERATURE MATERIAL PROCESSES, 2024, 28 (02): : 1 - 5
  • [43] HIGH-VOLTAGE ESCHERICHIA-COLI ELECTRO-TRANSFORMATION WITH DNA FOLLOWING LIGATION
    WILLSON, TA
    GOUGH, NM
    NUCLEIC ACIDS RESEARCH, 1988, 16 (24) : 11820 - 11820
  • [44] The effect of high-voltage pulse current on the infectious of schistosome cercariae in water
    Zhao, Z.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2015, 20 : 239 - 239
  • [45] LOW-TEMPERATURE STERILIZATION OF ORGANIC TISSUE BY HIGH-VOLTAGE CATHODE-RAY IRRADIATION
    MEEKER, IA
    GROSS, RE
    SCIENCE, 1951, 114 (2959) : 283 - 285
  • [46] Effect of temperature on survival rate in high electric field pulse sterilization
    Murakami, Y.
    Muramoto, Y.
    Shimizu, N.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 259 - 262
  • [47] STERILIZATION OF ESCHERICHIA-COLI BY HIGH-PRESSURE
    KAJIYAMA, N
    AKIZUMI, K
    ABEI, K
    NAGATA, M
    EGASHIRA, T
    MIYAKE, Y
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1993, 40 (06): : 406 - 413
  • [48] HIGH-POWER HIGH-VOLTAGE PULSE TRANSFORMER
    VDOVIN, SS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (03) : 690 - 692
  • [49] An avalanche transistor-based Marx circuit pulse generator with sub-nanosecond, high frequency and high-voltage for pathogenic Escherichia coli ablation
    Yin, Haocheng
    Zhao, Hang
    Sun, Lejia
    Jia, Jingqi
    Zhang, Zeyu
    Zhang, Yuming
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 191 : 1784 - 1792
  • [50] STERILIZATION OF PRESERVED BONE GRAFTS BY HIGH-VOLTAGE CATHODE IRRADIATION
    TURNER, TC
    BASSETT, CAL
    PATE, JW
    TRUMP, JG
    WRIGHT, K
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1956, 38 (04): : 862 - 884