Salutary Effects of the PULVAD, a Novel Implantable Counterpulsation Assist Device, on Cardiac Mechanoenergetics

被引:3
|
作者
Kontogiannis, Christos [1 ]
Aravantinos, Dionysios [1 ]
Nanas, Ioannis [1 ]
Kapelios, Chris J. [1 ]
Marinakis, Sotirios [1 ]
Vakrou, Styliani [1 ]
Sarchosi, Smaragdi [1 ]
Perrea, Despina N. [2 ]
Mason, Jay W. [3 ]
Nanas, John N. [1 ]
Malliaras, Konstantinos [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 3, 67 Mikras Asias St, GR-11527 Athens, Greece
[2] Univ Athens, Sch Med, Lab Expt Surg & Surg Res NS Christeas, Athens, Greece
[3] Univ Utah, Div Cardiol, Salt Lake City, UT 84112 USA
关键词
PULVAD; LVAD; counterpulsation; mechanical circulatory support; heart failure; INTRAAORTIC BALLOON PUMP; HEART-FAILURE; AORTIC COUNTERPULSATION; CLINICAL-EXPERIENCE; BRIDGE; PRESSURE; SUPPORT; LOAD; FLOW; DEPENDENCE;
D O I
10.1097/MAT.0000000000000838
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Pressure Unloading Left Ventricular Assist Vevice (PULVAD) is a novel implantable counterpulsation LVAD, designed to provide ventricular unloading with augmentation of LV performance and retention of pulsatility. We assessed the effects of the PULVAD on hemodynamics and LV mechanoenergetics in seven farm pigs with acute ischemic heart failure. The PULVAD was implanted in the thorax and was connected to the ascending aorta. The PULVAD was pneumatically driven by a standard intra-aortic balloon pump console and was electrocardiogram-synchronized to provide LV pressure unloading along with diastolic aortic pressure augmentation. Hemodynamics, indices of LV mechanoenergetics, and coronary blood flow were measured without and after brief PULVAD support. PULVAD support decreased LV afterload and improved LV mechanical performance (increased ejection fraction, stroke volume, cardiac output and maximum elastance). The PULVAD concurrently reduced LV energy consumption (decreased stroke work and pressure-volume area) and optimized LV energetic performance (improved the ratio of stroke work to pressure-volume area). PULVAD support increased mean coronary blood flow, through dramatic augmentation of diastolic blood flow. In conclusion, the PULVAD unloads the failing LV, optimizes LV mechanoenergetics, and augments coronary blood flow. These salutary effects of short-term PULVAD support provide the foundation for long-term testing.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 50 条
  • [31] Does successful bridging with the implantable left ventricular assist device affect cardiac transplantation outcome?
    Massad, MG
    McCarthy, PM
    Smedira, NG
    Cook, DJ
    Ratliff, NB
    Goormastic, M
    Vargo, RL
    Navia, J
    Young, JB
    Stewart, RW
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (05): : 1275 - 1281
  • [32] THE THERMO-CARDIOSYSTEMS IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE AS A BRIDGE TO CARDIAC TRANSPLANTATION
    SECHE, LA
    [J]. HEART & LUNG, 1992, 21 (02): : 112 - 114
  • [33] Automated implantable cardiac defibrillator and biventricular thoratec assist device as bridge to transplantation in a patient with sarcoidosis
    Ankersmit, HJ
    Wieselthaler, GA
    Moser, B
    Taghavi, S
    Grimm, M
    Roth, G
    Gorlitzer, M
    Tschernich, H
    Horvat, R
    Wolner, E
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (06): : 1198 - 1199
  • [34] Arrhythmias in Patients with Cardiac Implantable Electrical Devices after Implantation of a Left Ventricular Assist Device
    Rosenbaum, Andrew N.
    Kremers, Walter K.
    Duval, Sue
    Sakaguchi, Scott
    John, Ranjit
    Eckman, Peter M.
    [J]. ASAIO JOURNAL, 2016, 62 (03) : 274 - 280
  • [35] First evaluation of a novel epicardial cardiac assist device in animal experiments
    Ferrari, M
    Schlosser, M
    Brandes, H
    Werner, GS
    Schirra, S
    Wahlers, T
    Figulla, HR
    [J]. EUROPEAN HEART JOURNAL, 2003, 24 : 613 - 613
  • [36] HEMODYNAMIC-EFFECTS OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE (LVAD) IN THE CALF
    WITHINGTON, PS
    GRAHAM, T
    CAREY, C
    WHITE, D
    LEWIS, CT
    COLVIN, MP
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 (02) : P243 - P243
  • [37] THE MUSCLE-POWERED DUAL-CHAMBER COUNTERPULSATOR - RHEOLOGICALLY SUPERIOR IMPLANTABLE CARDIAC ASSIST DEVICE
    KOCHAMBA, G
    DESROSIERS, C
    DEWAR, M
    CHIU, RCJ
    [J]. ANNALS OF THORACIC SURGERY, 1988, 45 (06): : 620 - 625
  • [38] Does successful bridging with the implantable left ventricular assist device affect cardiac transplantation outcome? Discussion
    Rose, EA
    MorenoCabral, R
    Hill, JD
    VanMeter, C
    Massad
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (05): : 1282 - 1283
  • [39] Managing ventricular arrhythmias and implantable cardiac defibrillator shocks after left ventricular assist device implantation
    Soni, Bosky
    Gopinathannair, Rakesh
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (03) : 592 - 600
  • [40] Ruptured Intracranial Mycotic Aneurysm in Infective Endocarditis With Left Ventricular Assist Device and Implantable Cardiac Defibrillator Device: A Clinical Course
    Voruganti, D.
    Gajurel, K.
    Bhama, J. K.
    Cotarlan, V.
    [J]. TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) : 4064 - 4066