Salutary Effects of the PULVAD, a Novel Implantable Counterpulsation Assist Device, on Cardiac Mechanoenergetics

被引:3
|
作者
Kontogiannis, Christos [1 ]
Aravantinos, Dionysios [1 ]
Nanas, Ioannis [1 ]
Kapelios, Chris J. [1 ]
Marinakis, Sotirios [1 ]
Vakrou, Styliani [1 ]
Sarchosi, Smaragdi [1 ]
Perrea, Despina N. [2 ]
Mason, Jay W. [3 ]
Nanas, John N. [1 ]
Malliaras, Konstantinos [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 3, 67 Mikras Asias St, GR-11527 Athens, Greece
[2] Univ Athens, Sch Med, Lab Expt Surg & Surg Res NS Christeas, Athens, Greece
[3] Univ Utah, Div Cardiol, Salt Lake City, UT 84112 USA
关键词
PULVAD; LVAD; counterpulsation; mechanical circulatory support; heart failure; INTRAAORTIC BALLOON PUMP; HEART-FAILURE; AORTIC COUNTERPULSATION; CLINICAL-EXPERIENCE; BRIDGE; PRESSURE; SUPPORT; LOAD; FLOW; DEPENDENCE;
D O I
10.1097/MAT.0000000000000838
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Pressure Unloading Left Ventricular Assist Vevice (PULVAD) is a novel implantable counterpulsation LVAD, designed to provide ventricular unloading with augmentation of LV performance and retention of pulsatility. We assessed the effects of the PULVAD on hemodynamics and LV mechanoenergetics in seven farm pigs with acute ischemic heart failure. The PULVAD was implanted in the thorax and was connected to the ascending aorta. The PULVAD was pneumatically driven by a standard intra-aortic balloon pump console and was electrocardiogram-synchronized to provide LV pressure unloading along with diastolic aortic pressure augmentation. Hemodynamics, indices of LV mechanoenergetics, and coronary blood flow were measured without and after brief PULVAD support. PULVAD support decreased LV afterload and improved LV mechanical performance (increased ejection fraction, stroke volume, cardiac output and maximum elastance). The PULVAD concurrently reduced LV energy consumption (decreased stroke work and pressure-volume area) and optimized LV energetic performance (improved the ratio of stroke work to pressure-volume area). PULVAD support increased mean coronary blood flow, through dramatic augmentation of diastolic blood flow. In conclusion, the PULVAD unloads the failing LV, optimizes LV mechanoenergetics, and augments coronary blood flow. These salutary effects of short-term PULVAD support provide the foundation for long-term testing.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 50 条
  • [1] Salutary Effects of a Novel Implantable Counterpulsation Assist Device on Left Ventricular Mechanoenergetics in a Porcine Model of Acute Heart Failure
    Malliaras, Konstantinos
    Nanas, Yannis
    Kontogiannis, Chris
    Aravantinos, Dionysios
    Kapelios, Chris
    Marinakis, Sotirios
    Sarchosi, Smaragda
    Vakrou, Stella
    Perrea, Despina
    Nanas, John
    [J]. CIRCULATION, 2016, 134
  • [2] A novel implantable counterpulsation assist device optimizes left ventricular mechanoenergetics and improves myocardial perfusion in a porcine model of acute heart failure
    Kontogiannis, C.
    Aravantinos, D.
    Kapelios, C. J.
    Nanas, Y.
    Marinakis, S.
    Sarchosi, S.
    Charitos, C.
    Perrea, D.
    Nanas, J.
    Malliaras, K.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 518 - 518
  • [3] EFFECTS OF A NOVEL IMPLANTABLE COUNTERPULSATION ASSIST DEVICE ON LEFT VENTRICULAR MECHANOENERGETICS: COMPARISON WITH THE INTRA-AORTIC BALLOON PUMP IN A PORCINE MODEL OF ACUTE HEART FAILURE
    Kontogiannis, Christos
    Nanas, Yiannis
    Sarchosi, Smaragdi
    Kapelios, Christos
    Marinakis, Sotiris
    Aravantinos, Dionysios
    Tachliabouris, Ioannis
    Charitos, Christos
    Perrea, Despina
    Nanas, John
    Malliaras, Konstantinos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1386 - 1386
  • [4] Flow Field of a Novel Implantable Valveless Counterpulsation Heart Assist Device
    Berthe, A.
    Gaertlein, S.
    Lederer, Ch.
    Kertzscher, U.
    Affeld, K.
    Goubergrits, L.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (09) : 1982 - 1995
  • [5] Flow Field of a Novel Implantable Valveless Counterpulsation Heart Assist Device
    A. Berthe
    S. Gärtlein
    Ch. Lederer
    U. Kertzscher
    K. Affeld
    L. Goubergrits
    [J]. Annals of Biomedical Engineering, 2012, 40 : 1982 - 1995
  • [6] Performance analysis of a cardiac assist device in counterpulsation
    Chesler, NC
    Kamm, RD
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 437 - 445
  • [7] A novel implantable counterpulsation assist device, the PULVAD, induced superior left ventricular pressure unloading compared to the intra-aortic balloon pump in a bovine model of acute heart failure
    Marinakis, S.
    Nanas, Y.
    Sarchosi, S.
    Kontogiannis, C.
    Kapelios, C.
    Tachliabouris, I.
    Charitos, C.
    Nanas, J.
    Malliaras, K.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 254 - 254
  • [8] Profound pressure unloading induced by a novel implantable counterpulsation assist device in a porcine model of acute heart failure
    Kapelios, C.
    Kontogiannis, C.
    Nanas, Y.
    Aravantinos, D.
    Vlaras, E.
    Tachliabouris, I.
    Marinakis, S.
    Charitos, C.
    Nanas, J.
    Malliaras, K.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 120 - 121
  • [9] BIOCOMPATIBILITY TESTS OF COMPONENTS OF AN IMPLANTABLE CARDIAC ASSIST DEVICE
    VONRECUM, AF
    IMAMURA, H
    FREED, PS
    KANTROWITZ, A
    SHANTE, C
    EKSTROM, ME
    BAECHLER, CA
    BARNHART, MI
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1978, 12 (05): : 743 - 765
  • [10] Surgical technique and feasibility of implantation of a novel pressure unloading left ventricular assist device (PULVAD)
    Marinakis, S.
    Nanas, Y.
    Sarchosi, S.
    Kontogiannis, C.
    Kapelios, C.
    Tachliabouris, I.
    Vlaras, E.
    Charitos, C.
    Nanas, J.
    Malliaras, K.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 196 - 196