Performance of earthing systems of low resistivity soils

被引:41
|
作者
Nor, N. Mohamad [1 ]
Haddad, A.
Griffiths, H.
机构
[1] Multimedia Univ, Fac Engn, Selangor 63100, Malaysia
[2] Cardiff Univ, Sch Engn, Cardiff CF24 0YF, Wales
关键词
earth resistances; earthing systems; impulse characteristics; ionization; low resistivity soils;
D O I
10.1109/TPWRD.2006.874656
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a previous paper [1], the properties of sand with different water contents were investigated under high-magnitude fast-impulse currents, and an equivalent circuit model for soil ionisation was derived. For the hemispherical test cell used, resistance values in the kilo-ohm (Omega) range were obtained. These high values of resistance limited the current magnitudes to less than 300 A before breakdown occurred in the test cell. In practice, however, the resistance of an earth electrode is usually less than 10 Omega and the transient current magnitudes can reach several tens of kiloamperes. It is, therefore, necessary to investigate the behavior of soils under high current magnitudes and compare it with low ac and dc test results. In order,to achieve high impulse current magnitudes with the adopted test cell, low resistivity media were utilized as test soils. In this present paper, a new impulse test data using wet clay and sand mixed with controlled amounts of sodium chloride (NaCl) to obtain a range of low-resistivity materials, was analyzed. The characteristics of NaCl are also investigated under low-magnitude low-frequency and high-magnitude impulse currents in order to understand better its effect on sand-salt soil mixtures. Impulse currents up to 5 kA were used during the test program. These new data would be useful in understanding the characteristics of a low earth resistance value (which is a typical condition at field site) under high impulse conditions. By including the nonlinear effect of the soil under high currents, more accurate modelling of protective devices and their performance could be achieved. In addition, the consideration of the nonlinearity in soils can help the optimum design of earthing systems.
引用
收藏
页码:2039 / 2047
页数:9
相关论文
共 50 条
  • [41] SEASONAL COEFFICIENTS OF RESISTANCE FOR COMPLEX EARTHING SYSTEMS
    YAKOBS, AI
    ELECTRICAL TECHNOLOGY, 1969, 3 : 166 - &
  • [42] Global earthing systems in urban cable grids
    Mallits T.
    Fickert L.
    Schmautzer E.
    e & i Elektrotechnik und Informationstechnik, 2017, 134 (8) : 420 - 425
  • [43] Of international terminology and wiring methods used in the matter of bonding and earthing of low-voltage power systems
    Mitolo, Massimo
    Tartaglia, Michele
    Panetta, Sergio
    2009 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2009, : 16 - +
  • [44] Optimized Design of Earthing System for Substations with High Soil Resistivity and Limited Plot Area
    Bonda, Prudhvi Raj
    Mishra, Mahesh K.
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [45] THE COST AND EFFICIENCY OF EARTHING ON LOW-VOLTAGE AND MEDIUM-VOLTAGE OVERHEAD LINE SYSTEMS - DISCUSSION
    MALLET, R
    HARKUS, GN
    MORGAN, F
    JONES, ETL
    PICKEN, DA
    ARCHER, LJ
    LIRONI, TV
    HEWLETT, EW
    DAY, F
    BACON, CC
    GLOVER, KG
    JONES, L
    REECE, TE
    GOODALL, L
    HARVEY, L
    SZWANDER, W
    RENNIE, RJ
    FAWSSETT, E
    JACKSON, A
    MARRIAN, EJM
    HORE, RA
    WILKIE, JF
    MOODY, HS
    LLOYD, H
    CAVE, PW
    GOSLAND, L
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1953, 100 (75): : 328 - 332
  • [46] Impulse coefficient for square grounding grids in low resistivity soils: Influence of injection electrode
    de Oliveira, Rodrigo M. S.
    Modesto, Jonathas F. M.
    Maia, Marcos Rodrigo V.
    Fujiyoshi, Daiyuki Maia
    Raizer, Adroaldo
    JOURNAL OF ELECTROSTATICS, 2014, 72 (05) : 372 - 380
  • [47] An approach for fabricating high performance inductors on low resistivity substrates
    Xie, YH
    Frei, MR
    Becker, AJ
    King, CA
    Kossives, D
    Gomez, LT
    Theiss, SK
    PROCEEDINGS OF THE 1997 BIPOLAR/BICMOS CIRCUITS AND TECHNOLOGY MEETING, 1997, : 88 - 91
  • [48] Of International Terminology and Wiring Methods Used in the Matter of Bonding and Earthing of Low-Voltage Power Systems
    Mitolo, Massimo
    Tartaglia, Michele
    Panetta, Sergio
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (03) : 1089 - 1095
  • [49] Low frequency field of an earthing conductor by variational method
    Ivanyi, A., 1600, Budapest University of Technology and Economics, Budafoki ut 4, Budapest, H-1111, Hungary (33): : 1 - 2
  • [50] Transient electromagnetic fields near large earthing systems
    Grcev, LD
    Menter, FE
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (03) : 1525 - 1528