Numerical and Experimental Investigation on Forced-Air Cooling of Commercial Packaged Strawberries

被引:19
|
作者
Wang, Da [1 ,2 ]
Lai, Yanhua [1 ]
Zhao, Hongxia [1 ]
Jia, Binguang [1 ]
Wang, Qiang [3 ]
Yang, Xiangzheng [2 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] All China Federat Supply & Mkt Cooperat, Jinan Fruit Res Inst, Jinan 250014, Shandong, Peoples R China
[3] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Shandong, Peoples R China
基金
国家重点研发计划;
关键词
commercial packaged system; vent shape and area; cooling time; cooling coefficient; strawberry; VENT HOLE DESIGN; HEAT-TRANSFER; COLD CHAIN; FRUIT; QUALITY; FLOW; PRODUCE; PERFORMANCE; EFFICIENCY; SPHERES;
D O I
10.1515/ijfe-2018-0384
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The numerical simulation model of forced-air cooling of strawberries in a clamshell and a box was established by using computational fluid dynamics method. The cooling process of the simulation and the experiment results agreed well in different conditions, indicating that the simulation model was validated. The results showed that the 7/8 cooling time was 180 min, 135 min, 108 min and 100 min and the cooling uniformity coefficients were 0.31, 0.22, 0.24, 0.26 when the diameters of B-vent(the vent on the box) were 30 mm, 40 mm, 50 mm, 60 mm, respectively. The 7/8 cooling time decreased and the cooling uniformity coefficient improved, when the shape of C-vent (the vent on the clamshell) changed from round to rectangular. The 7/8 cooling time also deceased and the cooling uniformity coefficient increased, when the area of C-vent with both round and rectangular shapes increased. These results indicate that both B-vent and C-vent had significant effect on reducing the cooling time and the improving cooling uniformity for strawberries, It is suggested that the optimized vent ratio of B-vent (the diameter is 40 mm) and C-vent (15 mm round or 20 mm x 15 mm rectangular) for the current commercial packaged strawberries were 9.4 % and 8.5 %, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Commercial-scale forced-air cooling of packaged strawberries
    Anderson, BA
    Sarkar, A
    Thompson, JF
    Singh, RP
    [J]. TRANSACTIONS OF THE ASAE, 2004, 47 (01): : 183 - 190
  • [2] Forced-air cooling of strawberries in reusable plastic containers
    Meana, Melvin B.
    Chau, Khe V.
    Emond, Jean-Pierre
    Talbot, Michael T.
    [J]. PROCEEDINGS OF THE 118TH ANNUAL MEETING OF THE FLORIDA STATE HORTICULTURAL SOCIETY, 2005, 118 : 379 - 382
  • [3] Design guidelines for the forced-air cooling process of strawberries
    Ferrua, M. J.
    Singh, R. P.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (08): : 1932 - 1943
  • [4] Innovative Parallel Airflow System for forced-air cooling of strawberries
    Nalbandi, Habibeh
    Seiiedlou, Sadegh
    Ghasemzadeh, Hamid R.
    Rangbar, Faramarz
    [J]. FOOD AND BIOPRODUCTS PROCESSING, 2016, 100 : 440 - 449
  • [5] COMMERCIAL FORCED-AIR COOLING OF BLUEBERRIES IN NORTH CAROLINA
    KUSHMAN, LJ
    BALLINGE.WE
    [J]. PROCEEDINGS OF THE AMERICAN SOCIETY FOR HORTICULTURAL SCIENCE, 1968, 92 (JUN): : 788 - &
  • [6] Commercial forced-air precooling of strawberries: A temperature distribution and correlation study
    Mercier, Samuel
    Brecht, Jeffrey K.
    Uysal, Ismail
    [J]. JOURNAL OF FOOD ENGINEERING, 2019, 242 : 47 - 54
  • [7] Improved airflow method and packaging system for forced-air cooling of strawberries
    Ferrua, M. J.
    Singh, R. P.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 1162 - 1173
  • [8] MODELING AND SIMULATION OF FORCED-AIR COOLING OF STRAWBERRIES USING VARIABLE CONVECTIVE COEFFICIENT
    Siqueira, Alvaro J. H.
    da Costa, Andrea O.
    da Costa Junior, Esly F.
    [J]. ENGENHARIA AGRICOLA, 2012, 32 (01): : 164 - 173
  • [9] STUDY ON FORCED-AIR FORCED-AIR COOLING FOR DP WIRE ROD
    HANADA, Y
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1131 - 1131
  • [10] Experimental Study on Multiscale Thermodynamic Characteristics of Forced-air Cooling
    Wang, Guan-Bang
    Zhang, Xin-Rong
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (07): : 1565 - 1572