Commercial-scale forced-air cooling of packaged strawberries

被引:1
|
作者
Anderson, BA [1 ]
Sarkar, A [1 ]
Thompson, JF [1 ]
Singh, RP [1 ]
机构
[1] Univ Calif Davis, Dept Agr & Biol Engn, Davis, CA 95616 USA
来源
TRANSACTIONS OF THE ASAE | 2004年 / 47卷 / 01期
关键词
5-down trays; 7/8th cooling time; cooling coefficient; forced-air cooling; precooling; strawberries;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Strawberries are an extremely valuable crop, but they are also very sensitive to decay if not cooled and maintained at proper temperatures. Strawberries are typically packaged in the field and quickly transported to a cooling facility, where they are precooled by forcing cold air through the vents of the packaging. Over the last several years, there has been a shift in the packaging used for strawberries. Many of the open-top pint baskets have been replaced by clamshell designs with hinged lids and less vent area. In addition, there has been an increased retail demand for a larger tray that fits five trays to a pallet layer rather than six trays per layer. In this work, strawberries packaged in clamshell containers and a variety of tray designs were precooled in commercial cooling systems. To determine the speed of cooling for each treatment, both the 7/8th cooling time and the cooling coefficient were calculated. It was found that the control package combination (with a design that fits six trays per pallet layer) cooled significantly faster than the other treatments, which fit five trays per pallet layer It is thought that the cross-orientation of trays that occurs in the five trays per layer configuration may slow cooling if the vents are not designed properly. No major differences were found for cooling using corrugated trays versus returnable plastic containers. It was found that the clamshell container and tray should be designed together and chosen properly to allow maximum air-to-product contact during cooling. Variations in air temperature during commercial cooling tests may cause errors in determining 7/8th cooling times.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 50 条
  • [1] Numerical and Experimental Investigation on Forced-Air Cooling of Commercial Packaged Strawberries
    Wang, Da
    Lai, Yanhua
    Zhao, Hongxia
    Jia, Binguang
    Wang, Qiang
    Yang, Xiangzheng
    [J]. INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2019, 15 (07)
  • [2] Forced-air cooling of strawberries in reusable plastic containers
    Meana, Melvin B.
    Chau, Khe V.
    Emond, Jean-Pierre
    Talbot, Michael T.
    [J]. PROCEEDINGS OF THE 118TH ANNUAL MEETING OF THE FLORIDA STATE HORTICULTURAL SOCIETY, 2005, 118 : 379 - 382
  • [3] Design guidelines for the forced-air cooling process of strawberries
    Ferrua, M. J.
    Singh, R. P.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (08): : 1932 - 1943
  • [4] Innovative Parallel Airflow System for forced-air cooling of strawberries
    Nalbandi, Habibeh
    Seiiedlou, Sadegh
    Ghasemzadeh, Hamid R.
    Rangbar, Faramarz
    [J]. FOOD AND BIOPRODUCTS PROCESSING, 2016, 100 : 440 - 449
  • [5] COMMERCIAL FORCED-AIR COOLING OF BLUEBERRIES IN NORTH CAROLINA
    KUSHMAN, LJ
    BALLINGE.WE
    [J]. PROCEEDINGS OF THE AMERICAN SOCIETY FOR HORTICULTURAL SCIENCE, 1968, 92 (JUN): : 788 - &
  • [6] Commercial forced-air precooling of strawberries: A temperature distribution and correlation study
    Mercier, Samuel
    Brecht, Jeffrey K.
    Uysal, Ismail
    [J]. JOURNAL OF FOOD ENGINEERING, 2019, 242 : 47 - 54
  • [7] Improved airflow method and packaging system for forced-air cooling of strawberries
    Ferrua, M. J.
    Singh, R. P.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 1162 - 1173
  • [8] MODELING AND SIMULATION OF FORCED-AIR COOLING OF STRAWBERRIES USING VARIABLE CONVECTIVE COEFFICIENT
    Siqueira, Alvaro J. H.
    da Costa, Andrea O.
    da Costa Junior, Esly F.
    [J]. ENGENHARIA AGRICOLA, 2012, 32 (01): : 164 - 173
  • [9] STUDY ON FORCED-AIR FORCED-AIR COOLING FOR DP WIRE ROD
    HANADA, Y
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1131 - 1131
  • [10] Forced-air cooling of iceberg lettuces: Cooling efficiency in relation to commercial operating strategies
    Wang, Xi-Fang
    Fan, Zhong-Yang
    Li, Bao-Guo
    Liu, Sheng
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 139 : 84 - 92