Electrochemical sensor for Isoniazid based on the glassy carbon electrode modified with reduced graphene oxide-Au nanomaterials

被引:44
|
作者
Guo, Zhuo [1 ]
Wang, Ze-yu [1 ]
Wang, Hui-hua [2 ]
Huang, Guo-qing [1 ]
Li, Meng-meng [1 ]
机构
[1] Shenyang Univ Chem Technol, Dept Mat Sci & Engn, Shenyang 110142, Peoples R China
[2] Soochow Univ, Shagang Sch Iron & Steel, Suzhou 215021, Peoples R China
关键词
Reduced graphene oxide; Au nanoparticles; Isoniazid; Electrochemical sensor; SELECTIVE DETERMINATION; GOLD NANOPARTICLES; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL-PREPARATIONS; ELECTROCATALYTIC OXIDATION; AMPEROMETRIC DETERMINATION; MASS-SPECTROMETRY; DNA BIOSENSOR; NANOCOMPOSITE; RIFAMPICIN;
D O I
10.1016/j.msec.2015.07.045
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A sensitive electrochemical sensor has been fabricated to detect Isoniazid (INZ) using reduced graphene oxide (RGO) and Au nanocomposites (RGO-Au). RGO-Au nanocomposites were synthesized by a solution-based approach of chemical co-reduction of Au(III) and graphene oxide (GO), and were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, and Fourier transform infrared (FT-IR). The Au nanoparticles separate the RGO sheets in the precipitate and prevent RGO sheets from aggregation upon pi-pi stacking interactions. RGO-Au nanocomposites were used to modify the glassy carbon electrode (GCE). The electrochemical properties of RGO-Au/GCE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), and the RGO-Au/GCE exhibited remarkably strong electrocatalytic activities towards INZ. Under the optimized conditions, there was linear relationships between the peak currents and the concentrations in the range of 1.0 x 10(-7) M to 1.0 x 10(-3) M for INZ, with the limit of detection (LOD) (based on S/N = 3) of 1.0 x 10(-8) M for INZ. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [31] Electrochemical Sensor Based on Nafion/Gold Nanoparticle/Electrochemically Reduced Graphene Oxide Composite-Modified Glassy Carbon Electrode for the Detection of Diuron
    Qin, Jianfang
    Qin, YingLian
    Jiang, Xiuping
    Du, Yajin
    Du, Yajing
    Yao, Chen-Zhong
    Wang, Xi
    Yang, Haiying
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11203 - 11214
  • [32] A facile electrochemical sensor based on a composite of electrochemically reduced graphene oxide and a PEDOT:PSS modified glassy carbon electrode for uric acid detection
    Putra, Budi R.
    Nisa, Ulfiatun
    Heryanto, Rudi
    Rohaeti, Eti
    Khalil, Munawar
    Izzataddini, Arini
    Wahyuni, Wulan T.
    [J]. ANALYTICAL SCIENCES, 2022, 38 (01) : 157 - 166
  • [33] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    [J]. Microchimica Acta, 2011, 174 : 383 - 390
  • [34] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [35] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    [J]. MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [36] Designing an Au/reduced graphene oxide modified carbon paste electrode for the electrochemical quantification of agnuside
    Afzali, Moslem
    Mostafavi, Ali
    Shamspur, Tayebeh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 : 188 - 194
  • [37] An Amperometric Hydrogen Peroxide Sensor Based on Reduced Graphene Oxide/Carbon Nanotubes/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Cao, Qi
    Zhu, Fengmei
    Xu, Hedan
    Zhang, Yang
    Xu, Wenfeng
    Liao, Xiaoling
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8771 - 8785
  • [38] Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes
    Junhua Li
    Daizhi Kuang
    Yonglan Feng
    Fuxing Zhang
    Zhifeng Xu
    Mengqin Liu
    Deping Wang
    [J]. Microchimica Acta, 2013, 180 : 49 - 58
  • [39] The electrochemical sensor based on electrochemical oxidation of nitrite on metalloporphyrin-graphene modified glassy carbon electrode
    Li, C.
    Guo, B.
    Guo, X. M.
    Wang, F.
    [J]. RSC ADVANCES, 2016, 6 (93): : 90480 - 90488
  • [40] Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes
    Li, Junhua
    Kuang, Daizhi
    Feng, Yonglan
    Zhang, Fuxing
    Xu, Zhifeng
    Liu, Mengqin
    Wang, Deping
    [J]. MICROCHIMICA ACTA, 2013, 180 (1-2) : 49 - 58