DIRECT MEASUREMENTS OF SKIN, EYE LENS AND THYROID DOSE DURING PEDIATRIC BRAIN CT EXAMINATIONS

被引:7
|
作者
Ploussi, Agapi [1 ]
Stathopoulos, Ioannis [1 ]
Syrgiamiotis, Vasileios [2 ]
Makri, Triantafillia [2 ]
Hatzigiorgi, Christiana [2 ]
Platoni, Kalliopi [1 ]
Carinou, Eleftheria [3 ]
Efstathopoulos, Efstathios P. [1 ]
机构
[1] Univ Athens, Univ Gen Hosp Attikon, Sch Med, Dept Radiol 2, Athens 12462, Greece
[2] Childrens Hosp Agia Sophia, CT MRI Dept, Athens 11527, Greece
[3] GAEC, Attiki 15310, Greece
关键词
COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER-RISK; THRESHOLD; DOSIMETRY;
D O I
10.1093/rpd/ncx251
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pediatric brain computed tomography (CT) is identified as the most frequent CT examination in children. The aim of the study is the direct measurement of skin, eye lens and thyroid dose in pediatric patients during brain CT examinations. The study included 35 pediatric patients who underwent brain CT examinations. The patients were categorized in three age groups: Group A (age range: 0.8-1 years), Group B (age range: 2.0-4.9 years) and Group C (age range: 5.5-15.5 years). thermoluminescent dosimeters (TLDs) were placed on the eyes, the frontal region of the head, the mastoid apophysis and the thyroid gland. The skin dose was found 16.6 +/- 1.5, 38.8 +/- 5.1 and 41.7 +/- 9.4 mGy for Groups A, B and C, respectively. The mean dose for the eye lens was 10.5 +/- 3.3, 29.9 +/- 8.6 and 34.2 +/- 14.9mGy and for the thyroid 1.7 +/- 0.4, 2.4 +/- 0.5 and 1.9 +/- 0.4mGy for Groups A, B and C, respectively. In vivo dosimetry using TLDs proved to be an efficient method. Gantry tilting and patient's set-up seem to significantly affect eye lens dose.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [31] Risk Estimation of Thyroid Cancer for Children Undergoing Brain CT Examinations
    Ata, Morteza Majidi
    Moradi, Abbas
    Gharekhanloo, Farideh
    Nikzad, Safoora
    MIDDLE EAST JOURNAL OF CANCER, 2022, 13 (01) : 143 - 149
  • [32] Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth shield
    Lai, C. W. -K.
    Cheung, H. -Y.
    Chan, T. -P.
    Wong, T. H.
    RADIOPROTECTION, 2015, 50 (03) : 195 - 201
  • [33] ESTIMATION OF EYE LENS DOSE DURING BRAIN SCANS USING GAFCHROMIC XR-QA2 FILM IN VARIOUS MULTIDETECTOR CT SCANNERS
    Akhilesh, Philomina
    Kulkarni, Arti R.
    Jamhale, Shramika H.
    Sharma, S. D.
    Kumar, Rajesh
    Datta, D.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (02) : 236 - 241
  • [34] REDUCING ABSORBED DOSE TO THYROID IN NECK CT EXAMINATIONS: THE EFFECTS OF SABA SHIELDING
    Saba, Valiallah
    Shuraki, Jalal Kargar
    Valizadeh, Abdollah
    Zahedinia, Mohsen
    Barkhordari, Maziar
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 349 - 360
  • [35] Assessment of scatter radiation dose and absorbed doses in eye lens and thyroid gland during digital breast tomosynthesis
    Chusin, Thunyarat
    Matsubara, Kosuke
    Takemura, Akihiro
    Okubo, Rena
    Ogawa, Yoshinori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 340 - 347
  • [36] Radiation dose to the eye lens from coronal CT scanning of the sinuses
    Spencer, DH
    CLINICAL RADIOLOGY, 1996, 51 (09) : 666 - 666
  • [37] Direct Temperature Measurements of Cardiac Stent during MRI Examinations
    Acri, Giuseppe
    Campanella, Francesco
    Vermiglio, Giuseppe
    Anfuso, Carmelo
    Testagrossa, Barbara
    Cavallaro, Daniela
    Urzi, Domenica
    Sanzo, Antonio
    D'Avanzo, Maria Antonietta
    Hartwig, Valentina
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [38] Eye lens exposure of nuclear medicine technologists during PET/CT procedures: compliance with dose limits and eye lens vs whole-body dosimetry
    Ryser, M.
    Figueiredo, S.
    Medici, S.
    Prior, J. O.
    Cherbuin, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S151 - S151
  • [39] Estimating thyroid dose in pediatric CT exams from surface dose measurement
    Al-Senan, Rani
    Mueller, Deborah L.
    Hatab, Mustapha R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13): : 4211 - 4221
  • [40] Management of patient dose and image noise in routine pediatric CT abdominal examinations
    Francis R. Verdun
    D. Lepori
    Pascal Monnin
    Jean-François Valley
    Pierre Schnyder
    F. Gudinchet
    European Radiology, 2004, 14 : 835 - 841