Partial-discard strategy for obtaining high purity products using simulated moving bed chromatography

被引:64
|
作者
Bae, Youn-Sang [1 ]
Lee, Chang-Ha [1 ]
机构
[1] Yonsei Univ, Dept Chem Engn, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
partial-discard; partial feed; simulated moving bed (SMB) chromatography; purity; performance; enantiomer separation;
D O I
10.1016/j.chroma.2006.04.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new "partial-discard" operation strategy was developed to improve the performance, especially purity, achievable in simulated moving bed (SMB) chromatography. This strategy was applied to the four-zone SMB process with two columns per zone for binary separation within the linear range. The "partial-discard" strategy significantly enhanced the purity or enrichment when the discard time and discard length were controlled. In addition, the "partial-feed with partial-discard" strategy improved remarkably the extract and raffinate purities at an intermediate feed time compared with the "partial-feed" operation. Adjustments of the discard length and discard time played key roles in achieving the desired product purity in SMB chromatographic performance. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 173
页数:13
相关论文
共 50 条
  • [41] Separation of D-psicose and D-fructose using simulated moving bed chromatography
    Long, Nguyen Van Duc
    Le, Thai-Hoang
    Kim, Jin-li
    Lee, Ju Weon
    Koo, Yoon-Mo
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (11) : 1987 - 1995
  • [42] High-performance strategy of a simulated moving bed chromatography by simultaneous control of product and feed streams under maximum allowable pressure drop
    Song, Ji-Yeon
    Kim, Kyung-Min
    Lee, Chang-Ha
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1471 : 102 - 117
  • [43] Strategy of rearranging the port locations in a three-zone simulated moving bed chromatography for binary separation with linear isotherms
    Mun, Sungyong
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1230 : 100 - 109
  • [44] LARGE-SCALE SEPARATIONS BY LIQUID-CHROMATOGRAPHY USING SIMULATED MOVING-BED OPERATION
    BROUGHTON, DB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 9 - INDE
  • [45] Model Reduction for Linear Simulated Moving Bed Chromatography Systems Using Krylov-Subspace Methods
    Li, Suzhou
    Yue, Yao
    Feng, Lihong
    Benner, Peter
    Seidel-Morgenstern, Andreas
    AICHE JOURNAL, 2014, 60 (11) : 3773 - 3783
  • [46] Enantioseparation of racemic mandelic acid by simulated moving bed chromatography using Chiralcel-OD column
    Mao, Shimin
    Zhang, Yan
    Rohani, Sohrab
    Ray, Ajay K.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2014, 92 (07): : 1283 - 1292
  • [47] Continuous fractionation of enantiomer pairs in free solution using an electrophoretic analog of simulated moving bed chromatography
    Thome, B
    Ivory, CF
    JOURNAL OF CHROMATOGRAPHY A, 2002, 953 (1-2) : 263 - 277
  • [48] Steady-state analysis of simulated moving-bed chromatography using the linear, ideal model
    Zhong, GM
    Guiochon, G
    CHEMICAL ENGINEERING SCIENCE, 1998, 53 (06) : 1121 - 1130
  • [49] Magnetic/flow controlled continuous size fractionation of magnetic nanoparticles using simulated moving bed chromatography
    Kuger, Laura
    Arlt, Carsten-Rene
    Franzreb, Matthias
    TALANTA, 2022, 240
  • [50] Modification of a commercial chiral stationary phase - Influences on enantiomer separations using simulated moving bed chromatography
    Huthmann, E
    Juza, M
    JOURNAL OF CHROMATOGRAPHY A, 2001, 908 (1-2) : 185 - 200