Clinical and anatomic results of surgical repair of chronic rotator cuff tears at ten-year minimum follow-up

被引:22
|
作者
Elia, Fanny [1 ]
Azoulay, Vadim [1 ]
Lebon, Julie [1 ]
Faraud, Amelie [1 ]
Bonnevialle, Nicolas [1 ]
Mansat, Pierre [1 ]
机构
[1] Hop Univ Toulouse, Hop Pierre Paul RIQUET, Dept Orthopedie & Traumatol Urgences Mains, Pl Dr Baylac, F-31059 Toulouse, France
关键词
Rotator cuff tear; Fatty infiltration; Muscle atrophy; Prognosis factors; FULL-THICKNESS TEARS; LONG-TERM; FUNCTIONAL OUTCOMES; MASSIVE TEARS; SHOULDER; TENDON; INTEGRITY; SUPRASPINATUS; DEGENERATION; SUTURE;
D O I
10.1007/s00264-017-3456-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to evaluate long-term clinical and anatomic results after open rotator cuff repair. Materials and method Fifty-three patients were included in this study. Rotator cuff tears were limited to one tendon in 34, and two tendons or more in 19. The supraspinatus tendon was involved alone in 30 cases, and the subscapularis in four. Clinical, radiographic and MRI evaluations were performed for all patients at ten-year minimum follow-up. Results At 11.4-years average follow-up, satisfactory results were obtained with improvement on pain level, in range of motion with a gain in active anterior elevation and in external rotation as well as in strength in abduction. Absolute Constant score reached 74.7 points and adjusted Constant score 99.6%. SSV was 82.5% with a SST score of 10 points. Osteoarthritis changes increased with follow-up with osteoarthritis lesion in 69% of the cases. MRI evaluation found a re-tear of the repair in 42% of the cases: 30% when only the supraspinatus tendon was initially involved, and 63% when two or more tendons were repaired. Tear size and quality of the repair were the most important prognosis factors for re-tear of the repair. No correlation was found between the occurrence of a new tear and the clinical outcome. Conlcusion Surgical repair of chronic rotator cuff tendon tear can produce consistent and lasting pain relief and improvement in range of motion. Re-tear of the repair was not correlated with degradation of clinical results. Best results were obtained for isolated supraspinatus tear with a complete surgical repair.
引用
收藏
页码:1219 / 1226
页数:8
相关论文
共 50 条
  • [21] Arthroscopic repair of massive rotator cuff tears: A prospective cohort with 2-to 4-year follow-up
    Bennett, WF
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (04): : 380 - 390
  • [22] Arthroscopic repair of full-thickness tears of the rotator cuff: 2-to 14-year follow-up
    Wilson, F
    Hinov, V
    Adams, G
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (02): : 136 - 144
  • [23] Ten-year follow-up of a randomized controlled clinical trial in chronic hepatitis delta
    Wranke, Anika
    Hardtke, Svenja
    Heidrich, Benjamin
    Dalekos, George
    Yalcin, Kendal
    Tabak, Fehmi
    Gurel, Selim
    Cakaloglu, Yilmaz
    Akarca, Ulus S.
    Lammert, Frank
    Haeussinger, Dieter
    Mueller, Tobias
    Woebse, Michael
    Manns, Michael P.
    Idilman, Ramazan
    Cornberg, Markus
    Wedemeyer, Heiner
    Yurdaydin, Cihan
    JOURNAL OF VIRAL HEPATITIS, 2020, 27 (12) : 1359 - 1368
  • [24] Challenges in evaluating patients lost to follow-up in clinical studies of rotator cuff tears
    Norquist, BM
    Goldberg, BA
    Matsen, FA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06): : 838 - 842
  • [25] The results of arthroscopic versus mini-open repair for rotator cuff tears at mid-term follow-up
    Pearsall A.W.
    Ibrahim K.A.
    Madanagopal S.G.
    Journal of Orthopaedic Surgery and Research, 2 (1)
  • [26] SURGICAL-PROCEDURE AND RESULTS OF REPAIR OF MASSIVE TEARS OF THE ROTATOR CUFF
    NOBUHARA, K
    HATA, Y
    KOMAI, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (304) : 54 - 59
  • [27] Results of surgical repair of full-thickness tears of the rotator cuff
    Gupta, R
    Leggin, BG
    Iannotti, JP
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1997, 28 (02) : 241 - +
  • [28] FUNCTIONAL AND ANATOMIC RESULTS FOLLOWING SURGICAL REPAIR OF ROTATOR CUFF TEARS .2. POST OPERATIVE FUNCTIONAL AND ANATOMIC ASSESSMENT
    GAZIELLY, DF
    GLEYZE, P
    MONTAGNON, C
    BRUYERE, G
    PRALLET, B
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (01): : 17 - 26
  • [29] Ten-year follow-up of endometrial ablation
    Fuerst, Stine Nymann
    Philipsen, Torben
    Joergensen, Joergen Christian
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2007, 86 (03) : 334 - 338
  • [30] Arthroscopic superior capsule reconstruction with Teflon felt synthetic graft for irreparable massive rotator cuff tears: clinical and radiographic results at minimum 2-year follow-up
    Okamura, Kenji
    Abe, Masayuki
    Yamada, Yuichiro
    Makihara, Takeshi
    Yoshimizu, Takaki
    Sakaki, Yoshinari
    Suzumori, Yuki
    Mihata, Teruhisa
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (03) : 625 - 634