Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry

被引:3
|
作者
Yang, Yi [1 ]
Tang, Xiangyang [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
关键词
x-ray differential phase contrast imaging; x-ray Talbot interferometry; x-ray dark-field imaging; x-ray phase contrast CT; complex dark-field contrast; phase-attenuation duality; COMPUTED-TOMOGRAPHY; SIGNAL; GRATINGS;
D O I
10.1118/1.4896098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Under the existing theoretical framework of x-ray phase contrast imaging methods implemented with Talbot interferometry, the dark-field contrast refers to the reduction in interference fringe visibility due to small-angle x-ray scattering of the subpixel microstructures of an object to be imaged. This study investigates how an object's subpixel microstructures can also affect the phase of the intensity oscillations. Methods: Instead of assuming that the object's subpixel microstructures distribute in space randomly, the authors' theoretical derivation starts by assuming that an object's attenuation projection and phase shift vary at a characteristic size that is not smaller than the period of analyzer grating G(2) and a characteristic length d(c). Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the zeroth- and first-order Fourier coefficients of the x-ray irradiance recorded at each detector cell are derived. Then the concept of complex dark-field contrast is introduced to quantify the influence of the object's microstructures on both the interference fringe visibility and the phase of intensity oscillations. A method based on the phase-attenuation duality that holds for soft tissues and high x-ray energies is proposed to retrieve the imaginary part of the complex dark-field contrast for imaging. Through computer simulation study with a specially designed numerical phantom, they evaluate and validate the derived analytic formulae and the proposed retrieval method. Results: Both theoretical analysis and computer simulation study show that the effect of an object's subpixel microstructures on x-ray phase contrast imaging method implemented with Talbot interferometry can be fully characterized by a complex dark-field contrast. The imaginary part of complex dark-field contrast quantifies the influence of the object's subpixel microstructures on the phase of intensity oscillations. Furthermore, at relatively high energies, for soft tissues it can be retrieved for imaging with a method based on the phase-attenuation duality. Conclusions: The analytic formulae derived in this work to characterize the complex dark-field contrast in x-ray phase contrast imaging method implemented with Talbot interferometry are of significance, which may initiate more activities in the research and development of x-ray differential phase contrast imaging for extensive biomedical applications. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] X-ray refraction-contrast computed tomography images using dark-field imaging optics
    Sunaguchi, Naoki
    Yuasa, Tetsuya
    Huo, Qingkai
    Ichihara, Shu
    Ando, Masami
    APPLIED PHYSICS LETTERS, 2010, 97 (15)
  • [42] Simulation framework for coherent and incoherent X-ray imaging and its application in Talbot-Lau dark-field imaging
    Ritter, Andre
    Bartl, Peter
    Bayer, Florian
    Goedel, Karl C.
    Haas, Wilhelm
    Michel, Thilo
    Pelzer, Georg
    Rieger, Jens
    Weber, Thomas
    Zang, Andrea
    Anton, Gisela
    OPTICS EXPRESS, 2014, 22 (19): : 23276 - 23289
  • [43] Microstructure Analysis Using Visibility Contrast in X-ray Talbot Interferometry
    Yashiro, W.
    Terui, Y.
    Kawabata, K.
    Momose, A.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 321 - 324
  • [44] Quantitative Visibility-Contrast Tomography in the X-ray Talbot Interferometry
    Yashiro, Wataru
    Harasse, Sebastien
    Kuwabara, Hiroaki
    Kawabata, Katsuyuki
    Momose, Atsushi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 211 - 216
  • [45] Talbot interferometry with curved quasi-periodic gratings: towards large field of view X-ray phase-contrast imaging
    Sun, Yangyang
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    Pang, Shuo
    OPTICS EXPRESS, 2015, 23 (20): : 26576 - 26585
  • [46] Talbot phase-contrast x-ray imaging for the small joints of the hand
    Stutman, Dan
    Beck, Thomas J.
    Carrino, John A.
    Bingham, Clifton O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5697 - 5720
  • [47] Directional x-ray dark-field imaging
    Jensen, Torben H.
    Bech, Martin
    Bunk, Oliver
    Donath, Tilman
    David, Christian
    Feidenhans'i, Robert
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3317 - 3323
  • [48] Dark-field hyperspectral X-ray imaging
    Egan, Christopher K.
    Jacques, Simon D. M.
    Connolley, Thomas
    Wilson, Matthew D.
    Veale, Matthew C.
    Seller, Paul
    Cernik, Robert J.
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 470 (2165):
  • [49] X-ray dark-field imaging modeling
    Cong, W.
    Pfeiffer, F.
    Bech, M.
    Wang, G.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 908 - 912
  • [50] Simulation of dark-field imaging of micro-calcifications in human breast tissue with X-ray Talbot-Lau interferometry
    Ritter, A.
    Anton, G.
    Bayer, F.
    Goedel, K.
    Pelzer, G.
    Rieger, J.
    Weber, T.
    Zang, A.
    Michel, T.
    JOURNAL OF INSTRUMENTATION, 2014, 9