Experimental study on forced convective boiling heat transfer of pure refrigerants and refrigerant mixtures in a horizontal tube

被引:116
|
作者
Shin, JY [1 ]
Kim, MS [1 ]
Ro, ST [1 ]
机构
[1] SEOUL NATL UNIV,DEPT MECH ENGN,SEOUL 151742,SOUTH KOREA
关键词
refrigerant; zeotropic mixture; nucleated boiling; horizontal tube; heat transfer coefficient; measurement;
D O I
10.1016/S0140-7007(97)00004-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Convective boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R290, and R600a) and refrigerant mixtures (R32/R134a, R290/R600a, and R32/R125) are measured experimentally and compared with Gungor and Winterton correlation. The test section is made of a seamless stainless steel tube with an inner diameter of 7.7 mm and is uniformly heated by applying electric current directly to the tube. The exit temperature of the test section was kept at 12 degrees C +/- 0.5 degrees C for all refrigerants in this study. Heat fluxes are varied from 10 to 30 kW m(-2) and mass fluxes are set to the discrete values in the range of 424-742 kg m(-2) s(-1) for R22, R32, R134a, R32/R134a, and R32/R125; 265-583 kg m(-2) s(-1) for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases, The Gungor and Winterton correlation for pure substances and the Thome-Shakil modification of this correlation for refrigerant mixtures overpredicts the heat transfer coefficients measured in this study. (C) 1997 Elsevier Science Ltd and IIR.
引用
下载
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [21] Vertical forced convective boiling of refrigerant binary mixtures
    Celata, GP
    Cumo, M
    Setaro, T
    REVUE GENERALE DE THERMIQUE, 1997, 36 (04): : 253 - 263
  • [22] Forced convective boiling of nonazeotropic refrigerant mixtures of R22 and R114 inside a horizontal tube
    Miyara, Akio
    Takamatsu, Hiroshi
    Koyama, Shigeru
    Yonemoto, Kazuo
    Fujii, Tetsu
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1988, 54 (505): : 2523 - 2528
  • [23] FORCED CONVECTIVE BOILING IN HORIZONTAL TUBE BUNDLES
    HWANG, TH
    YAO, SC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1986, 29 (05) : 785 - 795
  • [24] Heat transfer in vertical forced convective boiling of binary mixtures
    Celata, GP
    Cumo, M
    Setaro, T
    CONVECTIVE FLOW BOILING, 1996, : 251 - 257
  • [25] Condensing heat transfer of pure refrigerants and refrigerant mixtures flowing within horizontal microfin tubes: A new model
    Mehendale, Sunil S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 103 : 223 - 242
  • [26] Nucleate pool boiling heat transfer of pure refrigerants and binary mixtures
    Zhaofu Sun
    Maoqiong Gong
    Yanfeng Qi
    Zhijian Li
    Jianfeng Wu
    Journal of Thermal Science, 2004, 13 : 259 - 263
  • [27] Nucleate Pool Boiling Heat Transfer of Pure Refrigerants and Binary Mixtures
    Zhaofu SUN Maoqiong GONG YanfengQI Zhijian LI JianfengWU Technical Institute of Physics and Chemistry
    Journal of Thermal Science, 2004, (03) : 259 - 263
  • [28] Nucleate Pool Boiling Heat Transfer of Pure Refrigerants and Binary Mixtures
    Sun, Zhaofu
    Gong, Maoqiong
    Qi, Yanfeng
    Li, Zhijian
    Wu, Jianfeng
    JOURNAL OF THERMAL SCIENCE, 2004, 13 (03) : 259 - 263
  • [29] Modelling of evaporation heat transfer of pure refrigerants and refrigerant mixtures in microfin tubes
    Charnra, L. M.
    Mago, P. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2007, 221 (04) : 443 - 454
  • [30] FORCED CONVECTIVE BOILING OF NONAZEOTROPIC REFRIGERANT MIXTURES INSIDE TUBES
    MURATA, K
    HASHIZUME, K
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (03): : 680 - 689