Compact high-resolution ion Doppler spectrometer for quartz ultraviolet line emissions

被引:13
|
作者
Gu, PM [1 ]
Nagata, M
McCollam, KJ
Jarboe, TR
Nelson, BA
Redd, AJ
机构
[1] Univ Calif Davis, Dept Appl Sci, Davis, CA 95616 USA
[2] Univ Washington, Aerosp & Energet Res Prgram, Seattle, WA 98195 USA
[3] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
[4] Himeji Inst Technol, Dept Elect Engn, Himeji, Hyogo 6712201, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 05期
关键词
D O I
10.1063/1.1711157
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-resolution quartz ultraviolet spectrometer based on a single compact 16-channel multianode photomultiplier tube (MAPMT) has been developed and tested on coaxial helicity injection and ohmic transformer current drive plasmas generated on the Helicity Injected Torus at the University of Washington. The use of the compact MAPMT allows a simple design with high light collection and high resolution for an ion Doppler shift diagnostic. The high quality and low cost of the design make it uniquely attractive for university scale plasma experiments. The Doppler shift of impurity ion emission lines from two chords of equal impact parameter but of opposite rotational sense is used to determine chord-averaged toroidal flow velocity. The width of the Doppler broadening is used to calculate the ion temperature. A detailed description of the ion Doppler spectrometer measurement system and some typical results are presented. (C) 2004 American Institute of Physics.
引用
收藏
页码:1337 / 1340
页数:4
相关论文
共 50 条
  • [21] A compact high-resolution spectrometer based on a segmented conical crystal analyzer
    Robledo, Jose I.
    Perez, Carlos A.
    Sanchez, Hector J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (04):
  • [22] High resolution extreme ultraviolet spectrometer for an electron beam ion trap
    Ohashi, Hayato
    Yatsurugi, Junji
    Sakaue, Hiroyuki A.
    Nakamura, Nobuyuki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08):
  • [23] High-resolution mass spectrometer for liquid metal ion sources
    Wortmann, Martin
    Ludwig, Arne
    Meijer, Jan
    Reuter, Dirk
    Wieck, Andreas D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (09):
  • [24] A high-resolution mass spectrometer to measure atmospheric ion composition
    Junninen, H.
    Ehn, M.
    Petaja, T.
    Luosujarvi, L.
    Kotiaho, T.
    Kostiainen, R.
    Rohner, U.
    Gonin, M.
    Fuhrer, K.
    Kulmala, M.
    Worsnop, D. R.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2010, 3 (04) : 1039 - 1053
  • [25] HIGH-RESOLUTION ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    SCHWARTZ, JC
    SYKA, JEP
    JARDINE, I
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) : 198 - 204
  • [26] U-Shaped Mobility Analyzer: A Compact and High-Resolution Counter-Flow Ion Mobility Spectrometer
    Wang, Keke
    Qiu, Ran
    Zhang, Xiaoqiang
    Gillig, Kent J.
    Sun, Wenjian
    ANALYTICAL CHEMISTRY, 2020, 92 (12) : 8356 - 8363
  • [27] A high-performance, high-resolution positron annihilation coincidence Doppler broadening spectrometer
    Van Petegem, S
    Van Waeyenberge, B
    Segers, D
    Dauwe, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 622 - 630
  • [28] HIGH-RESOLUTION CRYSTAL SPECTROMETER
    BITTER, M
    VONGOELER, S
    GOLDMAN, M
    HILL, K
    HORTON, RW
    SAUTHOFF, N
    STODIEK, W
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 698 - 698
  • [29] HIGH-RESOLUTION RAMAN SPECTROMETER
    NECHAEV, SY
    PONOMAREV, YN
    KVANTOVAYA ELEKTRONIKA, 1975, 2 (07): : 1400 - 1402
  • [30] High-Resolution Terahertz Spectrometer
    Klatt, Gregor
    Gebs, Raphael
    Schaefer, Hanjo
    Nagel, Michael
    Janke, Christof
    Bartels, Albrecht
    Dekorsy, Thomas
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2011, 17 (01) : 159 - 168