Traceable atomic force microscope dimensional metrology at NIST

被引:6
|
作者
Dixson, Ronald [1 ]
Orji, Ndubuisi G. [1 ]
Fu, Joseph [1 ]
Cresswell, Michael [1 ]
Allen, Rich [1 ]
Guthrie, Will [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
CD-AFM; metrology; CD; linewidth; reference measurement system; standards; calibration; traceability;
D O I
10.1117/12.656803
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Institute of Standards and Technology (NIST) has a multifaceted program in atomic force microscope (AFM) dimensional metrology. There are two major instruments being used for traceable AFM measurements at NIST. The first is a custom in-house metrology AFM, called the calibrated AFM (C-AFM). and the second instrument is a commercial critical dimension AFM (CD-AFM). The C-AFM has displacement metrology for all three axes traceable to the 633 nm wavelength of the Iodine-stabilized He-Ne laser. In the current generation of this system, the relative standard uncertainty of pitch and step height measurements is approximately 1.0 X 10(-3) for pitches at the micrometer scale and step heights at the 100 nm scale, as supported by several international comparisons. We expect to surpass this performance level soon. Since the CD-AFM has the capability of measuring vertical sidewalls, it complements the C-AFM. Although it does not have intrinsic traceability, it can be calibrated using standards measured on other instruments - such as the C-AFM, and we have developed uncertainty budgets for pitch. height. and linewidth measurements using this instrument. We use the CD-AFM primarily for linewidth measurements of near-vertical structures. At present, the relative standard uncertainties are approximately 0.2 % for pitch measurements and 0.4 % for step height measurements. As a result of the NIST single crystal critical dimension reference material (SCCDRM) project, it is possible to calibrate CD-AFM tip width with a 1 nm standard uncertainty. We are now using the CD-AFM to support the next generation of the SCCDRM project. In prototypes. we have observed features with widths as low as 20 nm and having uniformity at the 1 nm level.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Measurement of pitch and width samples with the NIST calibrated atomic force microscope
    Dixson, R
    Koning, R
    Vorburger, TV
    Fu, J
    Tsai, VW
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XII, 1998, 3332 : 420 - 432
  • [22] Atomic force microscope integrated into a scanning electron microscope for fabrication and metrology at the nanometer scale
    Holz, Mathias
    Reuter, Christoph
    Reum, Alexander
    Ahmad, Ahmad
    Hofmann, Martin
    Ivanov, Tzvetan
    Mechold, Stephan
    Rangelow, Ivo W.
    PHOTOMASK TECHNOLOGY 2019, 2019, 11148
  • [23] Measurements of pitch, height, and width artifacts with the NIST calibrated atomic force microscope
    Dixson, R
    Tsai, VW
    Vorburger, T
    Williams, ED
    Wang, XS
    Fu, J
    Koning, R
    PROCEEDINGS OF: ADVANCES IN SURFACE METROLOGY, 1997, : 70 - 75
  • [24] Pitch calibration by an active temperature controlled traceable atomic force microscope and a laser diffractometer
    Chen, CJ
    Pan, SP
    Chang, LC
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 89 - 94
  • [25] Atomic Force Microscope Cantilever Flexural Stiffness Calibration: Toward a Standard Traceable Method
    Gates, Richard S.
    Reitsma, Mark G.
    Kramar, John A.
    Pratt, Jon R.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2011, 116 (04): : 703 - 727
  • [26] Advanced 3D Metrology Atomic Force Microscope with Crosstalk Eliminated
    Hua, Yueming
    Coggins, Cynthia
    Park, Sung
    Park, Sang-il
    SCANNING MICROSCOPY 2010, 2010, 7729
  • [27] A new method to calibrate an atomic force microscope with the self- traceable chromium grating fabricated by atomic lithography
    Gu, Zhenjie
    Deng, Xiao
    Cai, Yanni
    Wang, Xinpan
    Yang, Feng
    INTERNATIONAL CONFERENCE ON OPTOELECTRONIC AND MICROELECTRONIC TECHNOLOGY AND APPLICATION, 2020, 11617
  • [28] Nanometric lateral scale development using an atomic force microscope with directly traceable laser interferometers
    Misumi, I.
    Gonda, S.
    Sato, O.
    Sugawara, K.
    Yoshizaki, K.
    Kurosawa, T.
    Takatsuji, T.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (07) : 2041 - 2047
  • [29] Traceable calibration of critical-dimension atomic force microscope linewidth measurements with nanometer uncertainty
    Dixson, RG
    Allen, RA
    Guthrie, WF
    Cresswell, MW
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2005, 23 (06): : 3028 - 3032
  • [30] Estimation of three-dimensional atomic force microscope tip shape from atomic force microscope image for accurate measurement
    Harada, Yasuhiko
    Sone, Hayato
    Hosaka, Sumio
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (07) : 6186 - 6189