The Temperature Changes in the Pulp Chamber During Cavity Preparation with the Er:YAG Laser Using a Very Short Pulse

被引:16
|
作者
Jukic Krmek, Silvana [1 ]
Miletic, Ivana [1 ]
Simeon, Paris [1 ]
Mehicic, Goranka Prpic [1 ]
Anic, Ivica [1 ]
Radisic, Berislav [2 ]
机构
[1] Univ Zagreb, Sch Dent Med, Dept Endodont & Restorat Dent, Gunduliceva 5, Zagreb 10000, Croatia
[2] Univ Zagreb, Fac Vet, Clin Surg Orthopaed & Ophthalmol, Zagreb 10000, Croatia
关键词
ER-YAG-LASER; ND-YAG; INTRAPULPAL TEMPERATURE; ABLATION; DENTIN;
D O I
10.1089/pho.2008.2247
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of this study was to examine the temperature changes in the pulp chamber during cavity preparation with the Er:YAG laser (2940 nm) with a very short pulse (VSP). Materials and Methods: Nine groups of 10 intact molars each were used. One root of each sample was amputated and a thermocouple was inserted into the chamber. Class V cavity preparation in enamel was performed, and then preparation was performed in dentine. The enamel was lased with 400, 360, and 320 mJ in contact mode using a VSP with a duration of 100 mu sec. The diameter of the fiber tip was 950 mu m. Frequencies of 10, 12, and 15 Hz were used, and the total time of irradiation was 10 sec. The dentine was irradiated with 340, 280, and 200 mJ at 10, 8, and 5 Hz for 7 sec. Cooling was done with a water spray (73 psi and 50 mL/min). The differences were tested by MANOVA and the Bonferroni post hoc test. Results: The highest rise in temperature in the pulp was achieved after enamel irradiation with 400 mJ and 15 Hz (1.99 +/- 0.28 degrees C), and the lowest was after irradiation with 320 mJ and 10 Hz (0.70 +/- 0.18 degrees C). In dentine the highest temperature increase was achieved with 340 mJ and 10 Hz (1.37 +/- 0.42 degrees C), and the lowest was with 200 mJ and 5 Hz (0.43 +/- 0.18 degrees C). Two-way analysis of both enamel and dentine showed that the influence of energy on temperature increase was stronger than that of frequency. Conclusion: Cavity preparation with an Er:YAG laser using VSP mode in vitro did not cause significant increases in temperature in the pulp chamber of human molars.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [21] A histopathological and immunohistochemical study of dental pulp and pulpal nerve fibers in rats after the cavity preparation using Er:YAG laser
    Takamori, K
    JOURNAL OF ENDODONTICS, 2000, 26 (02) : 95 - 99
  • [22] The use of Er:YAG laser for cavity preparation:: An SEM evaluation
    Freitas, Patricia Moreira
    Navarro, Ricardo Scarparo
    Barros, Juliana Almeida
    Eduardo, Carlos De Paula
    MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (09) : 803 - 808
  • [23] Cavity preparation with Er:YAG laser and adaptation restorative materials
    Haruyama, C
    Takizawa, M
    Amagai, T
    Kameyama, A
    Nishiyama, R
    Sugiyama, S
    Takahashi, K
    Hirai, Y
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1252 - 1252
  • [24] Clinical application of Er:YAG laser for cavity preparation in children
    Kato, J
    Moriya, K
    Jayawardena, JA
    Wijeyeweera, RL
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2003, 21 (03): : 151 - 155
  • [25] Acceptance and efficiency of Er:YAG laser for cavity preparation in children
    Liu, Jeng-Fen
    Lai, Yu-Lin
    Shu, Wun-Yu
    Lee, Shyh-Yuan
    PHOTOMEDICINE AND LASER SURGERY, 2006, 24 (04) : 489 - 493
  • [26] Accuracy of navigated control concepts using an Er:Yag-Laser for cavity preparation
    Wolff, Regine
    Weitz, Jochen
    Poitzsch, Luise
    Hohlweg-Majert, Bettina
    Deppe, Herbert
    Lueth, Tim C.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2101 - 2106
  • [27] Intrapulpar temperature changes with different Er:YAG pulses on class V cavity preparation.
    Brugnera, A
    Marchesan, MA
    Silva, RS
    Zanin, F
    Pecora, JD
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B129 - B129
  • [28] Temperature Changes of Pulp Chamber during In Vitro Laser Welding of Orthodontic Attachments
    Isman, Eren
    Oksayan, Ridvan
    Sokucu, Oral
    Usumez, Serdar
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [29] Cavity preparation using an Erbium:YAG laser
    Frame, JW
    BRITISH DENTAL JOURNAL, 2000, 188 (12) : 671 - 671
  • [30] Cavity preparation using an Erbium:YAG laser
    J W Frame
    British Dental Journal, 2000, 188 : 671 - 671